• 제목/요약/키워드: Strands

검색결과 409건 처리시간 0.025초

Electro-Micromechanical 시험법을 이용한 Ni Nanowire Strands 강화 고분자 복합재료의 Sensing과 계면 물성 평가 (Sensing and Interfacial Evaluation of Ni Nanowire Strands/Polymer Composites using Electro-micromechanical Technique)

  • 김성주;정진규;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.141-144
    • /
    • 2005
  • Sensing and interfacial evaluation of Ni nanowire strands/polymer composites were investigated using Electro-micromechanical technique. Electro-micromechanical techniques can be used as sensing method for micro damage, loading, temperature of interfacial properties. Using Ni nanowire strands/silicone composites with different content, load sensing response of electrical contact resistivity was investigated under tensile and compression condition. The mechanical properties of Ni nanowire strands with different type/epoxy composites were measured using uniformed cyclic loading and tensile test. Ni nanowire strands/epoxy composites showed humidity and temperature sensing within limited ranges, 20 vol% reinforcement. Some new information on temperature and humidity sensing plus loading sensing of Ni nanowire strands/polymer composites could be obtained from the electrical resistance measurement as a new concept of the nondestructive interfacial evaluation.

  • PDF

국산 저이완 PS 강연선의 피로특성에 관한 연구 (A Study on Fatigue Characteristics of Domestic Low-Relaxation PS Strands)

  • 변근주;송하원;박상순;노병철
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.113-119
    • /
    • 1999
  • Fatigue failure is a phenomenon such that structures under cyclic service load is failed by sudden brittle manner. Therefore, in order to obtain structures safety against the fatigue failure during their service lifes, fatigue characteristics should be considered for design and analysis of the structures. As stress range of prestressed (PS) tendons, which governs fatigus characteristic of prestressed concrete (PSC) structures, increases with increased use of partial prestressig, it is more necessary to consider fatigue characteristics of PS tendons. In this paper, direct-tension fatigue experiments with special specimen-setting devices are carried out to obtain fatigue characteristics of domestic low relaxation PS strands having different diameters and PS strands connected with coupler. Then, allowable stress range of fatigue for PSC beams using low relaxation strands are presented for the fatigue examination of prestressed concrete beams applied cyclic loading.

Tensile behavior of new 2,200 MPa and 2,400 MPa strands according to various types of mono anchorage

  • Kim, Jin Kook;Seong, Taek Ryong;Jang, Kyung Pil;Kwon, Seung Hee
    • Structural Engineering and Mechanics
    • /
    • 제47권3호
    • /
    • pp.383-399
    • /
    • 2013
  • High-strength strands are widely used as a key structural element in cable-stayed bridges and prestressed concrete structures. Conventional strands for stay cable and tendons in prestressed concrete structures are ${\phi}$15.7mm coated seven-wire strands and ${\phi}15.2mm$ uncoated seven-wire strands, respectively, but the ultimate strengths of both strands are 1860MPa. The objective of this paper is to investigate the tensile behavior of a newly developed ${\phi}15.7mm$ 2,200 MPa coated strand and a ${\phi}15.2mm$ 2,400 MPa uncoated strand according to various types of mono anchorages and to propose appropriate anchorages for both strands. Finite element analyses were initially performed to find how the geometry of the anchor head affects the interaction among the anchor head, the wedge and the strand and to find how it affects the stress distributions in both parts. Tensile tests for the new strands were carried out with seven different types of mono anchorages. The test results were compared to each other and to the results obtained from the tensile tests with a grip condition. From the analysis and the test results, desirable mono anchorages for the new strands are suggested.

2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능 (The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands)

  • 김선우;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.63-71
    • /
    • 2018
  • 인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.

프리텐션 슬래브 구조에서 긴장강선 용접절단순서에 따른 긴장재 및 콘크리트의 응력변화 고찰 (Investigation of Stress Changes in Concrete and Strands according to Cutting Order of the Strands in Pre-tensioned Concrete Slab)

  • 문도영;김장호;김규선;윤만근;지광습
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.419-429
    • /
    • 2009
  • 이 논문에서는 긴장력 도입을 위한 강선의 용접절단순서가 강선의 변형률과 콘크리트 응력에 미치는 영향 을 실험과 유한요소해석을 통해 고찰하였다. 실험에서는 각각 다른 3개의 용접절단순서에 따른 강선과 횡방향 보강 철 근의 변형률 변화를 계측하였다. 해석에서는 실험과 동일한 조건에 대한 유한요소해석을 수행하였으며, 그 결과를 실험 결과와 비교·고찰하였다. 연구 결과, 강선의 변형률과 횡방향 보강근의 변형률이 긴장재의 절단순서에 따라 다른 결과 를 나타내는 것을 확인하였다. 또한 이 결과는 해석을 통하여도 검증되었다. 따라서 프리스트레스 구조물의 시공시 구 조특성에 따라 적절한 절단순서의 조절이 고려되어야 한다.

국내산 7연강선의 트렌스퍼 정착부착 실험 (Transfer Bond test on Domestic Sevenwire Prestressing Strands)

  • 김승욱;김대훈;유재천;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.387-392
    • /
    • 1999
  • The bond performance of prestressing strands is still not well understood and is still in controversy on the validity of the test results up to today, although it is a basic information to desing the prestressed pretensioned concrete beams. Different transfer length has been found for a product of the same company, but of the different production methods and factories in the United States. It is necessary to determine optimum transfer bond length of the domestic stands because the ultimate flexural and shear capacity in a section of prestressed concrete beams are evaluated under the assumption that the anchorage bond failure shall not happen. The transfer lenght of low-relaxation, Gr 270, and 1/2" seven-wire prestressing strands from four domestic companies will be evaluated by the concrete strain method. The recent concept of the 95% Maximum Average Strain Method suggested by Russel et al. will be considered to obtain the transfer length of domestic strands. It will be also evaluated if the domestic strands are conform to ACI 318-95.8-95.

  • PDF

CIC 초전도 도체의 안정성 (Stability of the Cable-in-Conduit Conductors)

  • 류경우
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권9호
    • /
    • pp.895-900
    • /
    • 1997
  • A Quench in cable-in-conduit (CIC) conductors is often initiated by a disturbance such as strand motion that generates a highly localized normal zone in a strand or a few strands of the CIC conductors. The localized normal zone causes current and heat transfer between a disturbed strand and neighboring strands. Electrical and thermal contact characteristics between strands thus have an effect on the transient stability of the CIC conductors. In this paper the effect of contact characteristics between strands on the CIC conductor stability is presented based on the measured heat transfer characteristics of supercritical helium (SHe) for the local heating. The quench and recovery processes of the strands for the abrupt and highly localized disturbance are analyzed at the boundary between quench and recovery.

  • PDF

Taxonomic Considerations on the Bast Fibres in the Genus Sida L. (Malvaceae) in Nigeria

  • Oladele, F.A.
    • Journal of Plant Biology
    • /
    • 제29권2호
    • /
    • pp.135-143
    • /
    • 1986
  • The distributional pattern of the bast fibres strands or bundles in the stems of Sida species represented in Nigeria is studied. Three major patterns of arrangement are recognized, namely aggregation of fibre strands into units with wedge-shaped, or triangular, rectangular, rhomboidal, square and trapezoid outlines; serial arrangement of fibre strands into rings or circular, ovoid, semi-circular or crescentic rows; and intermediate pattern in which both fibre strands-aggregates and serial rows of strands patterns are combined. The first pattern is found in S. linifolia, S. urens and S. scabrida, the second in S. cordifolia, S. pilosa, S. ovata, S. rhombifolia and S. spinosa, and the third in S. garckeana, and S. acuta. A dichotomous key based on these features is presented. Dimensional characteristics of the bast fibre cells are also given.

  • PDF

Wavelet-based feature extraction for automatic defect classification in strands by ultrasonic structural monitoring

  • Rizzo, Piervincenzo;Lanza di Scalea, Francesco
    • Smart Structures and Systems
    • /
    • 제2권3호
    • /
    • pp.253-274
    • /
    • 2006
  • The structural monitoring of multi-wire strands is of importance to prestressed concrete structures and cable-stayed or suspension bridges. This paper addresses the monitoring of strands by ultrasonic guided waves with emphasis on the signal processing and automatic defect classification. The detection of notch-like defects in the strands is based on the reflections of guided waves that are excited and detected by magnetostrictive ultrasonic transducers. The Discrete Wavelet Transform was used to extract damage-sensitive features from the detected signals and to construct a multi-dimensional Damage Index vector. The Damage Index vector was then fed to an Artificial Neural Network to provide the automatic classification of (a) the size of the notch and (b) the location of the notch from the receiving sensor. Following an optimization study of the network, it was determined that five damage-sensitive features provided the best defect classification performance with an overall success rate of 90.8%. It was thus demonstrated that the wavelet-based multidimensional analysis can provide excellent classification performance for notch-type defects in strands.

Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam

  • Yang, Jun-Mo;Yim, Hong-Jae;Kim, Jin-Kook
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.577-591
    • /
    • 2016
  • In this study, the transfer length of 2400 MPa, seven-wire high-strength steel strands with a 15.2 mm diameter in pretensioned prestressed concrete (PSC) beams utilizing high strength concrete over 58 MPa at prestress release was evaluated experimentally. 32 specimens, which have the variables of concrete compressive strength, concrete cover depth, and the number of PS strands, were fabricated and corresponding transfer lengths were measured. The strands were released gradually by slowly reducing the pressure in the hydraulic stressing rams. The measured results of transfer length showed that the transfer length decreased as the concrete compressive strength and concrete cover depth increased. The number of strands had a very small effect, and the effect varied with both the concrete cover depth and concrete strength. The results were compared to current design codes and transfer lengths predicted by other researchers. The comparison results showed that the current transfer length prediction models in design codes may be conservatively used for 2400 MPa high-strength strands in high-strength concrete beams exceeding 58 MPa at prestress release.