• Title/Summary/Keyword: Strain recovery rate

Search Result 76, Processing Time 0.024 seconds

Application of Automated Microscopy Equipment for Rock Analog Material Experiments: Static Grain Growth and Simple Shear Deformation Experiments Using Norcamphor (유사물질 실험을 위한 자동화 현미경 실험 기기의 적용과 노캠퍼를 이용한 입자 성장 및 단순 전단 변형 실험의 예)

  • Ha, Changsu;Kim, Sungshil
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.233-245
    • /
    • 2021
  • Many studies on the microstructures in rocks have been conducted using experimental methods with various equipment as well as natural rock studies to see the development of microstructures and understand their mechanisms. Grain boundary migration of mineral aggregates in rocks could cause grain growth or grain size changes during metamorphism or deformation as one of the main recrystallization mechanisms. This study suggests improved ways regarding the analog material experiments with reformed equipment to see sequential observations of these grain boundary migration. It can be more efficient than the existing techniques and carry out an appropriate microstructure analysis. This reformed equipment was implemented to enable optical manipulation by mounting polarizing plates capable of rotating operation on a stereoscopic microscope and a deformation rig capable of experimenting with analog materials. The equipment can automatically control the temperature and strain rate of the deformation rig by microcontrollers and programming and can take digital photomicrographs with constant time intervals during the experiment to observe any microstructure changes. The composite images synthesized using images by rotated polarizing plates enable us to see more accurate grain boundaries. As a rock analog material, norcamphor(C7H10O) was used, which has similar birefringence to quartz. Static grain growth and simple shear deformation experiments were performed using the norcamphor to verify the effectiveness of the equipment. The static grain growth experiments showed the characteristics of typical grain growth behavior. The number of grains decreases and the average grain size increases over time. These case experiments also showed a clear difference between the growth curves with three temperature conditions. The result of the simple shear deformation experiment under the medium temperature-low strain rate showed no significant change in the average grain size but presented the increased elongation of grain shapes in the direction of about 53° regarding the direction perpendicular to the shearing direction as the shear strain increases over time. These microstructures are interpreted as both the plastic deformation and the internal recovery process in grains are balanced by the deformation under the given experimental conditions. These experiments using the reformed equipment represent the ability to sequentially observe changing the microstructure during experiments as desired in the tests with the analog material during the entire process.

Studies on Cryopreservation of 8-Cell Mouse Embryos (생쥐 8세포기 수정란의 동결보존에 관한 연구)

  • 최미후;이규승;박칭식;서길웅
    • Korean Journal of Animal Reproduction
    • /
    • v.11 no.3
    • /
    • pp.155-160
    • /
    • 1987
  • This study was carried out to determine the effects of cryoprotectants, freezing and thawing rates on the survival of 8-cell mouse embryos. The female ICR mice were induced to superovulated by intraperitoneal injections of 5 i.u. PMSG and 5 i.u. HCG given 48h apart and then were paired with males of the same strain. They were killed and embryos were flushed from the oviducts and uteri on 3 days after injection of HCG. Embryos were flushed with modified Dulbecco's phosphate buffered saline and equilibrated with 1.5M-dimethyl sulfoxide (DMSO) or 1.5M-glycerol by 3-step procedure. The freezing rates of the embryos were 1$^{\circ}C$/min from room temperature to -5$^{\circ}C$ and the embryos were seeded at -5$^{\circ}C$. After being held for 3 min at the seeding temperature, the rates were 0.3$^{\circ}C$/min from -5$^{\circ}C$ to -35$^{\circ}C$. From -35$^{\circ}C$ to -7$0^{\circ}C$, the rates were divided into 0.1$^{\circ}C$/min, 1$^{\circ}C$/min and 1$0^{\circ}C$/min, respectively. After being held for 5 min at -7$0^{\circ}C$, the embryos were plunged directly into liquid nitrogen. The embryos were thawed at 4$^{\circ}C$/min and 12$^{\circ}C$/min from -196$^{\circ}C$ to 37$^{\circ}C$, and for 2 min in 37$^{\circ}C$ water bath, respectively. The average number of ovulation points and embryos recovered were 42.7 and 34 appearing 79.5% recovery rate. Eight cell embryos in the embryos recovered were 26.3. The survival rates of embryos according to the freezing rates in the presence of 1.5M-DMSO were 73.5~80.6% at 0.1$^{\circ}C$/min, 75.0~79.5% at 1$^{\circ}C$/min and 52.8~54.7% at 1$0^{\circ}C$/min, but in the presence of 1.5M-glycerol were 62.9~67.6% at 0.1$^{\circ}C$/min, 61.4~68.3% at 1$^{\circ}C$/min and 25.5~30.2% at 1$0^{\circ}C$/min. The survival rates of embryos were not affected by the thawing rates.

  • PDF

A Study on the Development of Impact Analysis Model of Roll Control System for Course Correction Munition (탄도 수정탄 롤제어시스템 충격해석 모델 개발에 관한 연구)

  • Ko, Jun Bok;Yun, Chan Sik;Kim, Yong Dae;Kim, Wan Joo;Cho, Seung Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.737-742
    • /
    • 2015
  • Course correction munition are a weapson system for precision attacks and are assembled by applying a ballistic control system to existing projectiles. The roll control system is a subsystem of the ballistic control system and is placed between the guidance and control units inside of the projectile, which undergoes a 5000g lateral acceleration. Thus, it is very important to design the system to endure this load. Many developed countries evaluate the performance and safety of course correction munitions' parts using live-fire gun launch tests or a soft recovery system. However, these methods are expensive and slow. Thus, in this study, we develop impact analysis model of the roll control system using CAE. We apply the code to simulate impact phenomenon and use Johnson-Cook material model for modeling the high strain rate effect on the materials. We also design bearings in detail to analyze their behavior and verify the reliability of CAE model through gas-gun impact tests of the roll control system.

A Clinical Study about the Comparison of Clinical Characteristics Between Male and Female Patients with Headache (두통(頭痛)의 남녀(男女) 차이(差異)에 관한 임상적(臨床的) 고찰(考察) - ${\ll}$동의보감(東醫寶鑑).기(氣)${\gg}$의 용약법(用藥法)을 중심(中心)으로 -)

  • Lee, Byung-Gwon;Kam, Chul-Woo;Park, Dong-Il;Kim, Won-Il;Kwon, Kyoung-Man;Kim, Koang-Lok;Lee, Su-Young;Bae, Su-Hyun;Kang, Na-Ru
    • Korean Journal of Acupuncture
    • /
    • v.28 no.2
    • /
    • pp.59-75
    • /
    • 2011
  • Objectives : The Aim of this study was to investigate the clinical characteristics of male and female patients who have been suffered from headaches. The investigation was undertaken based on Qi-section(Methods of prescribing oriental herbal medicine) from DongEuiBoGam(東醫寶鑑). Methods: A statistical survey was conducted to compare the difference in clinical characteristics between male and female patients experiencing headaches. Oriental medical Diagnosis was used to classify all parients under the following categories Qi-deficiency (氣虛), Jing-dificiency (精虛), Food-stagnation (食積), Damp-accumulation (痰飮), Qi-stagnation (氣滯). Patients were treated using acupuncture therapy and herbal medicines. Results : 1. The ratio between male and female patients was about 1:3. 2. It showed that periods of illness were longer in female patients than in male patients. 3. The total number of treatments received was higher in female patients than in male patients. 4. Statistically, most female patients had Metopodynia and Migraines(Rt.), while male patients suffered mostly from Laryngalgia. 5. Male patients had feelings of strain in the head and female patients had splitting headaches. 6. Musculo-skeletal System and General Symptoms were frequently observed in male patients. Digestive System and Nervous System were frequently observed in female patients. 7. Results from oriental medical Diagnosis showed that male patients mostly had Qi-deficiency, ling-deficiency while the majority of female patients had Food-stagnation, Damp-accumulation, Qi-stagnation. 8. The recovery time for male patients was shorter than it was for female patients. The recurrence rate of the headaches were higher for female patients. Prognosis was better than in female patients in comparison to male patients. Conclusions : The statistical survey conducted was based on Qi-section of DongEuiBoGam. It had significant differences in clinical characteristics between male & femal patients.

Application of Various Types of Surfactants for Improving Hydrophilic Properties of Polyvinylsiloxane Dental Rubber Impression Materials and its Effects on Physical Properties (폴리비닐실록산 치과용 고무인상재의 친수성 향상을 위한 계면활성제의 응용과 물성에 미치 는 영향)

  • Park, Yeong-Joon;Hwang, Moon-Jin;Kim, Min-Kang;Song, Ho-Jun;Ha, Kwang;Kang, Shin-Young
    • Elastomers and Composites
    • /
    • v.43 no.2
    • /
    • pp.88-103
    • /
    • 2008
  • This study was purposed to investigate the effects of surfactants and fillers on physical properties of hydrophilic polyvinylsiloxane dental impression materials (PVS). Incorporation of surfactants enhanced the hydrophilicity of the PVS, however, it induced increased viscosity and permanent deformation ratio, delayed setting, and decreased tensile strength. At high concentrations of surfactant, the tensile strength was observed to decrease significantly due to the internal pore formation. Especially, the hydrophilicity of the PVS was significantly enhanced with the addition of Silwet L-77. However, the viscosity, strain in compression, pore formation, and setting time increased whereas the elastic recovery rate and strength remarkably decreased. The PVS dental materials containing Span 20 showed the lowest degree of viscosity increase, delayed setting, pore formation, and hydrophilicity. The delayed setting, pore formation, and strength decrease caused by the incorporation of surfactant were improved by substituting the crystalline quartz filler with diatomaceous earth while the contact angle of PVS dental materials increased.

Selection and Cultural Characteristics of Whole Chicken Feather-Degrading Bacterium, Bacillus sp. SMMJ-2 (Whole Chicken Feather-Degrading Keratinolytic Protease 생산균주의 분리 및 특성)

  • Park Sung-Min;Jung Hyuck-Jun;Yu Tae-Shick
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • Feather, generated in large quantities as a byproduct of commercial poultry processing, is almost pure keratin, which is not easily degradable by common professes. Four strains, SMMJ-2, FL-3, NO-4 and RM-12 were isolated from soil for production of extracellular keratinolytic protease. They were identified as Bacillus sp. based on their morphological and physiological characteristics. They shown high protease activity on 5.0% skim milk agar medium and produced a substrate like mucoid on keratin agar medium. Bacillus sp. SMMJ-2 had a faster production time for producing keratinolytic protease than other strains. This strain did not completely degrade whole chicken feather for five days in basal medium but completely degraded whole chicken feather when supplied with nitrogen source for 40hours in keratinolytic producing medium ($0.7%\;K_{2}HPO_{4},\;0.2%\;KH_{2}PO_{4},\;0.1%$ fructose, 1.2% whole chicken feather, $0.01%\;Na_{2}CO_3$, pH 7.0). When supplied with chicken feather as nitrogen source, keratinolytic protease activity was 89 units/ml/min. When soybean meal was used as nitrogen source, the keratinolytic protease production reached a maximum of 106 units/ml/min after 48 hours under $30^{\circ}C$, 180 agitation. To isolate the keratinolytic protease, the culture filtrate was precipitated with $(NH_4)_{2}SO_4$ and acetone. The recovery rate of keratinolytic protease was about 96% after treatment with 50% acetone. The enzyme was stable in the range of $30{\sim}50^{\circ}C$ and pH $6.0{\sim}12.0$.