• Title/Summary/Keyword: Strain Rate Distribution

Search Result 180, Processing Time 0.034 seconds

A Seroimmunologic Study of Bats Infected with Hantavirus in Korea ($1989{\sim}1995$) (한국 박쥐의 한타바이러스 감염에 대한 혈청면역학적 연구)

  • Park, Eun-Byung;Cho, Kyu-Bong;Park, Chul-Hee;Lee, Yun-Tai
    • The Journal of Korean Society of Virology
    • /
    • v.26 no.1
    • /
    • pp.91-99
    • /
    • 1996
  • To understand whether the bats inhabiting in Korea play role as hosts harboring Hantavirus that cause acute febrile diseases, a total number of 802 bats of 9 species were collected from seven provinces in Korea from 1989 to 1995 and tested for the presence of antibodies to Hantavirus by means of immunofluorescent antibody (IFA) technique. The results are summarized as follow. 1. Total 802 captured bats were classified into 9 different species with the following distribution. They were Rhinolophus ferrumequinum, Eptesicus serotinus, Miniopterus sehreibersii, Vespertilio superans, Myotis mystatinus, Murina leucogaster, Myotis formosus, Myotis macrodactylus and Plecotus auritus with numbers and rates of 423 (52.74%), 291 (36.28%), 47 (5.86%), 28 (3.49%), 8 (1.00%), 1 (0.12%) and 1 (0.12%), respectively. The predominant species of the bats was Rhinolophus ferrumequinum with 52.74% of the captured. 2. Among 9 species of bats, species of Rhinolophus ferrumequinum and Eptesicus serotinus were positive with Hantavirus antibody of strain numbers 76-118. The rate of antibody positive was 3.78%. 3. The seasonal differences of Hantavirus antibody in 802 bats tested were 5.83%, 4.17%, 3.67% and 0.64% in winter, spring, summer and autumn, respectively. Again the highest viral antibody prevalence was detected in winter. It could be concluded through the study that certain species of bats inhabiting in Korea play a definite role as the host animals of certain species of Hantavirus.

  • PDF

SEROTYPES AND ANTIBIOTIC SUSCEPTIBILITIES OF STREPTOCOCCUS MUTANS ISOLATED FROM DENTAL PLAQUES OF CHILDREN (치아우식아동과 그의 모친(母親)의 치태(齒苔)에서 분리(分離)한 Streptococcus mutans의 혈청형(血淸型) 분포(分布) 및 약제내성(藥劑耐性)에 관(關)한 연구(硏究))

  • Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.75-89
    • /
    • 1984
  • A total of 141 strains of Streptococcus mutans were isolated from dental plaques of 153 subjects. Eighty-two children with caries-experience, 18 caries-free children and their mothers were participated. All isolates were examined for their serotypes by immunodiffusion method with 7 reference sera and their antibiotic susceptibilities to 7 antibiotics by agar dilution method using 7 kinds of antibiotics, and were compared their results by caries experience (DMFT ratio) and by intrafamilial levels. 1. Isolation rate of Streptococcus mutans were greater in samples of carious teeth than those of sound teeth, and in mothers than in children. 2. Multiple serotypes of Streptococcus mutans were occasionally found in a single samples. 3. Of the total 141 isolates (83 isolates from children, and 58 from their mothers), type c isolates were most prevalent (63.8%). Type d,e and f were found, comprizing 14.9%, 10.6% and 6.4% respectively. Serotype g, a and untypable strain were also found but far lower frequencies (2.8-0.7%), and type b was detected. 4. These results suggest that there are no significant correlation among the distribution of serotypes, antibiotic susceptibilities, caries experience and intrafamilial relationships. 5. Most of isolates were susceptible to chloramphenicol (100%), penicillin (95.7%), ampicillin (94.3%), and gentamicin (92.2%), but about one-third isolates were resistant to cephaloridine (27%), streptomycin (33.3%) and kanamycin (47.6%), resulting that 91 strains (64.5%) among 141 isolates were resistant to one or more drugs used. 6. Of the 91 resistant strains, 20 different resistant patterns were observed, and the most frequently encountered patterns were KM, SM and CE.

  • PDF

Changes of the Flame Temperature and OH Radical in the Unsteady Extinction Process (비정상 소화 과정에서의 화염 온도 및 OH 라디칼의 변화)

  • Lee, Uen-Do;Lee, Ki-Ho;Oh, Kwang-Chul;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1557-1566
    • /
    • 2004
  • A flame extinction phenomenon is a typical unsteady process in combustion. Flame extinction is characterized by various physical phenomena, such as convection, diffusion, and the production of heat and mass. Flame extinction can be achieved by either increasing the strain rate or curvature, by diluting an inert gas or inhibitor, or by increasing the thermal or radiant energy loss. Though the extinction is an inherently transient process, steady and quasi-steady approaches have been used as useful tools for understanding the flame extinction phenomenon. Recently, unsteady characteristics of flames have been studied by many researchers, and various attempts have been made to understand unsteady flame behavior, by using various extinction processes. Representative parameters for describing flame, such as flame temperature, important species related to reactions, and chemi-luminescence of the flame have been used as criterions of flame extinction. In these works, verification of each parameter and establishing the proper criterions of the extinction has been very important. In this study, a time-dependent flame temperature and an OH radical concentration were measured using optical methods, and the instantaneous change of the flame luminosity was also measured using a high-speed ICCD (HICCD) camera. We compare the unsteady extinction points obtained by three different methods, and we discuss transient characteristics of maximum flame temperature and OH radical distribution near the extinction limit.

The Effect of Thermomechanical Treatment on the Transformation Characteristics and Mechanical Properties in a Cu-Al-Ni-Ti-Mn Alloy (Cu-Al-Ni-Ti-Mn 합금의 변태특성 및 기계적 성질에 미치는 가공열처리의 영향)

  • Kim, C.D.;Lee, Y.S.;Yang, G.S.;Jang, W.Y.;Kang, J.W.;Baek, S.N.;Gwak, S.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.145-156
    • /
    • 1999
  • The distribution of the second phase, the change of transformation temperature and mechanical properties with thermomechanical treatment conditions were investigated by metallography, calorimetry, EDS, tensile test and fractography in a Cu-Al-Ni-Ti-Mn alloy. The cast structure revealed Ti-rich precipitates($X_L$ phase) between dendrite arms, which have been identified as $(Cu,Ni)_2TiAl$ intermetallic compounds. By homogenizing above $900^{\circ}C$, the $X_L$ phase was melted in the matrix, while the Xs phase was precipitated in matrix and the volume fraction of it was increased. When hot-rolled specimen was betatized below $750^{\circ}C$, recrystallization could not be observed. However, the specimen betatized above $800^{\circ}C$ was recrystallized and the grain size was about $50{\mu}m$, while Xs phase was precipitated in matrix. With raising betatizing temperature, $M_s$ and $A_s$ temperatures were fallen and transformation hysteresis became larger. The strain of the specimen betatized at $800^{\circ}C$ was 8.2% as maximum value. The maximum shape recovery rate could be obtained in the specimen betatized at $800^{\circ}C$ but it was decreased due to the presence of Xs phase with increasing betatizing temperature.

  • PDF

The Effect of In-Outlet Differential Pressure on a Valve Body Stress and Deformation by the Blow-by Gas Flow Characteristic in the PCV valve for Automobile (자동차용 PCV밸브내 유통특성에 의한 밸브응력 및 변형에 미치는 입출구 차압의 영향)

  • Kwon Oh-Heon;Lee Yeon-Won;Song Sang-Min;Lee Jong-Hoon;Kang Ji-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.36-41
    • /
    • 2005
  • PCV(Positive Crankcase Ventilation) valve acts as a flow control valve to get a re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. The blow-by gas of the crankcase should be eliminated or taken properly because it cause corrosion to critical parts, and contributes to increase crankcase pressure that can cause a drop in efficiency. The excessive stress and strain on the PCV valve that remove these harmful gas would be bring the difficult on the flow rate control and failure of the valve. Those condition inevitably induce the accident. Therefore, this study purpose is FEM evaluation of the stresses and deformation in the X3 PCV model according to the change of the differential pressure between inlet and outlet. From results, the maximum equivalent stresses increased linearly according to the increase of the differential pressure at the about 50mm from the inlet position and were under the yield strength of the valve. And the deformations were relatively small regardless of the in-outlet differential pressure variation.

Investigation of infection rate and genetic sequence analysis of chicken infectious anemia virus (닭 전염성빈혈 감염률 및 유전자 분석)

  • Chu, Keum-Suk;Kang, Mi-Seon;Song, Hee-Jong;Lee, Jeong-Won
    • Korean Journal of Veterinary Service
    • /
    • v.33 no.1
    • /
    • pp.13-21
    • /
    • 2010
  • Chicken anemia virus (CAV) has been recognized as an immunosuppressive agent and plays role as an etiological agent of multifactorial diseases in chicken. In this study, we investigated distribution of CAV antibody by ELISA and the virus gene by PCR in poultry farms in Jeongeup, Jeonbuk province. In the test using ELISA kit, 41 (95.3%) of 43 flocks and 88.6% of the individual chickens were positive, respectively. By PCR, 90.9% of the broiler breeders and 75.0% of White-semi breeders were found positive, respectively. All hatchery was negative by PCR. Of the clinical cases from 49 poultry flocks, 87.5% of flocks and 54.7% for each samples were found positive by ELISA, respectively. By PCR test, 21 (42.9%) of 49 flocks were positive. Major clinical signs of the infected flocks were growth retardation, femoral subcutaneous bleeding, depression, limping, and continuing selection. The genetic analysis of separate N genes of CAV showed highly homologous each other. The nucleotide sequence of field isolates had homology ranged from 99.9% to 97.5% with Chinese strains, and 99.9% to 99.6% with Japanese strain. Phylogenetic analysis based on the N gene of CAV isolates showed the closely relation with Chinese strains. The results of this survey could be used as basic data for development of vaccine.

Evaluation on Flexural Performance of Precast Decks with Ribbed Joint by FEM (유한요소해석에 의한 요철형 이음단면을 갖는 프리캐스트 바닥판의 휨성능 평가)

  • Oh, Hyun-Chul;Chung, Chul-Hun;Kang, Myoung-Gu;Park, Se-Jin;Shin, Dong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • In this study, a non-linear FEM model is presented to predict the static flexural performance of precast bridge decks with ribbed joint and is verified with previous experiment results through comparison. The several theory of material properties were applied to each mechanical properties in FEM model and FEM model's input variables were determined through experiment result and parametric study. The FEM results showed good accuracy in predicting the structural performance of the specimens and FEM model's average error rate was 5%. Also, each specimen's cracking aspect and failure mode can be predicted through FEM's plastic strain distribution. Thus, this FEM model can be used effectively for predicting the ultimate behavior and parametric study to development of design formula for joint.

Effects of Impeller Geometry on the 11α-Hydroxylation of Canrenone in Rushton Turbine-Stirred Tanks

  • Rong, Shaofeng;Tang, Xiaoqing;Guan, Shimin;Zhang, Botao;Li, Qianqian;Cai, Baoguo;Huang, Juan
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.6
    • /
    • pp.890-901
    • /
    • 2021
  • The 11α-hydroxylation of canrenone can be catalyzed by Aspergillus ochraceus in bioreactors, where the geometry of the impeller greatly influences the biotransformation. In this study, the effects of the blade number and impeller diameter of a Rushton turbine on the 11α-hydroxylation of canrenone were considered. The results of fermentation experiments using a 50 mm four-blade impeller showed that 3.40% and 11.43% increases in the conversion ratio were achieved by increasing the blade number and impeller diameter, respectively. However, with an impeller diameter of 60 mm, the conversion ratio with a six-blade impeller was 14.42% lower than that with a four-blade impeller. Data from cold model experiments with a large-diameter six-blade impeller indicated that the serious leakage of inclusions and a 22.08% enzyme activity retention led to a low conversion ratio. Numerical simulations suggested that there was good gas distribution and high fluid flow velocity when the fluid was stirred by large-diameter impellers, resulting in a high dissolved oxygen content and good bulk circulation, which positively affected hyphal growth and metabolism. However, a large-diameter six-blade impeller created overly high shear compared to a large-diameter four-blade impeller, thereby decreasing the conversion ratio. The average shear rates of the former and latter cases were 43.25 s-1 and 35.31 s-1, respectively. We therefore concluded that appropriate shear should be applied in the 11α-hydroxylation of canrenone. Overall, this study provides basic data for the scaled-up production of 11α-hydroxycanrenone.

Seismic fragility evaluation of arch concrete dams through nonlinear incremental analysis using smeared crack model

  • Moradloo, Javad;Naserasadi, Kiarash;Zamani, Habib
    • Structural Engineering and Mechanics
    • /
    • v.68 no.6
    • /
    • pp.747-760
    • /
    • 2018
  • In the present study, a methodology for developing fragilities of arch concrete dams to assess their performance against seismic hazards is introduced. Firstly, the probability risk and fragility curves are presented, followed by implementation and representation of the way this method is used. Amirkabir arch concrete dam was subjected to non-linear dynamic analyses. A modified three dimensional rotating smeared crack model was used to take the nonlinear behavior of mass concrete into account. The proposed model considers major characteristics of mass concrete. These characteristics are pre-softening behavior, softening initiation criteria, fracture energy conservation, suitable damping mechanism and strain rate effect. In the present analysis, complete fluid-structure interaction is included to account for appropriate fluid compressibility and absorptive reservoir boundary conditions. In this study, the Amirkabir arch concrete dam is subjected to a set of 8 three-component earthquakes each scaled to 10 increasing intensity levels. Using proposed nonlinear smeared crack model, nonlinear analysis is performed where the structure is subjected to a large set of scaled and un-scaled ground motions and the maximum responses are extracted for each one and plotted. Based on the results, fragility curves were plotted according to various and possible damages indexes. Discrete damage probabilities were calculated using statistical methods for each considered performance level and incremental nonlinear analysis. Then, fragility curves were constructed based on the lognormal distribution assumption. Two damage indexes were introduced and compared to one another. The results indicate that the dam has a proper stability under earthquake conditions at MCE level. Moreover, displacement damages index is more conservative and impractical in the fragility analysis than tensional damage index.

Thaw consolidation behavior of frozen soft clay with calcium chloride

  • Wang, Songhe;Wang, Qinze;Xu, Jian;Ding, Jiulong;Qi, Jilin;Yang, Yugui;Liu, Fengyin
    • Geomechanics and Engineering
    • /
    • v.18 no.2
    • /
    • pp.189-203
    • /
    • 2019
  • Brine leakage is a common phenomenon during construction facilitated by artificial freezing technique, threatening the stability of frozen wall due to the continual thawing of already frozen domain. This paper takes the frequently encountered soft clay in Wujiang District as the study object, and remolded specimens were prepared by mixing calcium chloride solutions at five levels of concentration. Both the deformation and pore water pressure of frozen specimens during thawing were investigated by two-stage loading tests. Three sections were noted from the changes in the strain rate of specimens during thawing at the first-stage load, i.e., instantaneous, attenuated, and quasi-stable sections. During the second-stage loading, the deformation of post-thawed soils is closely correlated with the dissipation of pore water pressure. Two characteristic indexes were obtained including thaw-settlement coefficient and critical water content. The critical water content increases positively with salt content. The higher water content of soil leads to a larger thaw-settlement coefficient, especially at higher salt contents, based on which an empirical equation was proposed and verified. The normalized pore water pressure during thawing was found to dissipate slower at higher salt contents, with a longer duration to stabilize. Three physical indexes were experimentally determined such as freezing point, heat conductivity and water permeability. The freezing point decreases at higher salt contents, especially as more water is involved, like the changes in heat conductivity. The water permeability maintains within the same order at the considered range of salt contents, like the development of the coefficient of consolidation. The variation of the pore volume distribution also accounts for this.