• 제목/요약/키워드: Strain Gauge System

검색결과 201건 처리시간 0.027초

이미지 상관법의 서브 픽셀 알고리즘을 이용한 측정 분해능 향상에 관한 연구 (Study on Improvement of Measurement Precision in Digital Image Correlation Measurement Method by Using Subpixel Algorithms)

  • 김성종;강영준;최인영;홍경민;유원재
    • 한국정밀공학회지
    • /
    • 제32권12호
    • /
    • pp.1039-1047
    • /
    • 2015
  • Contact type sensors (e.g., displacement sensor and strain gauge) were typically used to evaluate the safety and mechanical properties in machines and construction. However, those contact type sensors have been constrained because of measurement problems such as surface roughness, temperature, humidity, and shape. The Digital Image Correlation (DIC) measurement system is a vision measurement system. This measurement system uses the taken image using a CCD camera and calculates the image correlation between the reference image and the deformed image under external force to measure the displacement and strain rates. In this paper, we discuss methods to improve the measurement precision of the digital image correlation measurement system. A tensile test was conducted to compare the precision improvement effects, by using the universal test machine and the DIC measurement system, with the use of subpixel algorithms, i.e., the Coarse Fine Search (CFS) algorithm and the Peak Finding (PF) algorithm.

광섬유센서를 이용한 열차하중 작용시 레일의 변형을 모니터링 (Strain monitoring of the rail during train loading condition using optical fiber sensor)

  • 윤혁진;송광용;김대상;김기환;김정석;권태수;나희승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1514-1518
    • /
    • 2009
  • Recently, railroad construction has been increased all over the world and as the train is getting high-speeded, there has been a need for guaranteed safety, so that a requirement for heath monitoring techniques for destruction that generated by gradually accumulated damages is now increasing. Especially the rail is crucial part that contact with wheel directly and delivers the train's load to a sleeper. It needs a technique that can guarantee a safety by sensing the possible cracks. In this paper, when train's load applied to the rail, strain distribution that introduced to entire length of rail is monitored using optical fibre. Optical fibre is used as a medium for measuring the strain and BOCDA (Brillouin Optical Correlation Domain Analysis) system is organized for measuring the distributed variation that implied to optical fibre. Optical fibre is attached at lower flange where tension is maximized when the load of train applied to the rail and strain gauge is implied together to compare the accuracy of measurement.

  • PDF

ESPI에 의한 원공판의 2차원 면내변위 측정에 관한 연구 (A study on the measurement of two-dimensional in-plane displacements of the plate with a circular hole by ESPI method)

  • 김경석;최형철;양승필;김형수;홍명석;정운관
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.161-170
    • /
    • 1994
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interfermetry(ESPI) method, in measuring two-dimensional in- plane displacement. The analysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversial point, measurement error. This error is discussed to be affected not by ESPI method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. Further development of advanced first-order interpolation method is being undertaken for the more precise in-plane strain measurement.

  • PDF

Fabrication of Micromachined Ceramic Thin-Film Pressure Sensors for High Overpressure Tolerance

  • Chung, Gwiy-Sang
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2002년도 추계학술대회 발표 논문집
    • /
    • pp.59-63
    • /
    • 2002
  • This paper reports on the fabrication process and characteristics of a ceramic thin-film pressure sensor based on Ta-N strain-gauges for harsh environment applications. The Ta-N thin-film strain-gauges are sputter-deposited on a thermally oxidized micromachined Si diaphragms with buried cavities for overpressure tolerance. The proposed device takes advantage of the good mechanical properties of single-crystalline Si as a diaphragm fabricated by SDB and electrochemical etch-stop technology, and in order to extend the temperature range, it has relatively higher resistance, stability and gauge factor of Ta-N thin-films more than other gauges. The fabricated pressure sensor presents a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is 1.21 ~ 1.097 mV/V.kgf/$\textrm{cm}^2$ in temperature ranges of 25~ $200^{\circ}C$ and a maximum non-linearity is 0.43 %FS.

  • PDF

부분탈피 고정방식 프리스트레인 가변형 광섬유격자센서를 이용한 지하철 구조물 변위 모니터링시스템 (Monitoring System For The Subway Structures Using Prestrained FBG Sensors Fixed With Partially Stripped Fibers)

  • 김기수
    • 한국전산구조공학회논문집
    • /
    • 제21권6호
    • /
    • pp.607-613
    • /
    • 2008
  • 광섬유의 클래딩 부분을 별도의 고정구에 직접 부착하는 방식으로 고정하여, 변형발생 시 광케이블을 구성하는 재료들 사이에서 발생하는 미끄러짐(Slip)현상을 방지하고, 외력에 의해 발생하는 변형을 정확하게 측정이 가능하도록 함과 기존 광섬유격자센서가 자체적으로 압축변형의 측정이 곤란한 점을 개선하기 위해 미리 긴장(Pre-Strain)상태를 유지하기 위하여 두 개의 접점사이를 볼트와 너트로 조절하여 프리스트레인 가변이 가능하도록 하여 인장/압축변형 측정을 가능하게 한 광섬유격자센서 패키지를 사용하는 지하구조물 변위 모니터링시스템이 본 연구에 의해 개발되었다. 이러한 광섬유격자센서 패키지는 콘크리트 라이닝구조물에 콘크리트의 불균일성을 극복하고 대표성을 가지기 위해 1미터 게이지 길이를 갖도록 하여 모니터링시스템에 적용되었으며, 대구 지하철 지하구조물에 현재 운영 중인 이 시스템은 한국전력 공동구 설치공사가 진행되면서 구조물에 미치는 영향을 판단하기 위한 모니터링시스템으로 적용되었다.

레일리파 기반의 고감도 변형률 센서에 관한 연구 (A Study on a Highly Sensitive Strain Sensor based on Rayleigh Wave)

  • 이기정;조민욱;;은경태;오해관;좌성훈;양상식
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.495-501
    • /
    • 2014
  • Piezoresistive-type, capacitive-type, and optical-type sensors have mainly been used for measuring a strain. However, in building a sensor network for remote monitoring using these conventional sensors there are disadvantages such as the complexity of a measuring system including wireless communication circuitry and high cost. In this paper, we demonstrates a highly-sensitive surface acoustic wave (SAW) strain sensor which is advantageous to harsh environments and wireless network. We designed and fabricated the SAW strain sensor. The SAW strain sensor attached on a specimen was tested with a tensile tester. The strain on the sensor surface was measured with a commercial strain gauge and compared with that obtained from strain analysis. The central frequency shift of the SAW sensor was measured with a network analyzer. The sensitivity of the SAW strain sensor is 134 $Hz/{\mu}{\varepsilon}$ which is high compared to previous results.

부분 무기둥 비계구조 골조 거동에 관한 실험적 연구 (An Experimental Study on the Behavior of Scaffolding System without a Part of Column)

  • 손기상;정희종
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.66-71
    • /
    • 2013
  • There is a critically structural problem of scaffolding system when one of scaffold columns is remove to be used as a gangway for their temporary office in the structure before finishing all such as an apartment or office building. This is not used to checking to structurally checking at a construction site. This study is to find out which system at a site will be more effective and low-cost-high effectiveness of aluminum ladder, timber ladder, ${\phi}$1/2 inch steel pipe truss with a type of concave, convex warren truss ladders. Theses are structurally tested with horizontal set as a truss type with 1.8 meter long. Concentrated load has been loaded at the upper center of the system and checked its strain at the bottom center, using aluminum-use strain gage and steel-use gauge have been attached concave warren truss with diameter 1/2 inch has 14% stronger than convex truss. Convex truss has almost same strength as an aluminum ladder truss, it is found out.

수완계 진동 평가에 영향을 미치는 작용력의 측정 (Measurement of Grip and Feed Force in the Evaluation of Hand-arm Vibration)

  • 최석현;장한기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1038-1042
    • /
    • 2003
  • In order to evaluate dynamic impedance of a hand-arm system it is necessary to measure the hand-transmitted vibration and the reaction force at the same time while gripping the vibrating handle. In the study a device was developed to measure both the vibration and the force. The device consists of a measurement handle with four strain gauge and two accelerometers and a PC based control system with a program for the signal processing and evaluation of the hand-transmitted vibration and reaction force. The handle was installed on the vibration shaker so that it can move by the generated signal from the control system. As an application of the system dynamic reaction force and the frequency weighted acceleration at the handle attached to the shaker were measured at various grip force and feed force. This system will be very useful in the area of impedance measurement and the evaluation of performance of anti-vibration gloves.

  • PDF

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

고정밀 밀링가공을 위한 공구처짐 보정시스템 개발 (Development of a Tool Deflection Compensation System for Precision End-milling)

  • 최종근;양민양
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.42-46
    • /
    • 1993
  • This paper presents development of a pratical tool deflection compensation system in order to reduce the machining error by the tool deflection in the end-milling process. The system is a tool adapter which includes 2-axis force sensor for detecting tool deflection and 2-axis tool tilting device for adjusting tool position through computer interface in on-line process. In experiments, it is revealed that the force sensor applying parallel plate principle and strain gauge is proper to obtain dynamic process signal, and the tilting device using stepping motor and cam drive mechanism is suitable to have necessary action. By the system and control algorithm, it is possible to get precise machining surface profile without excessive machining error and overcut generated due to increased cutting force in more productive machining condition.

  • PDF