• Title/Summary/Keyword: Straight Rectangular Channel

Search Result 18, Processing Time 0.028 seconds

Microflow of dilute colloidal suspension in narrow channel of microfluidic-chip under Newtonian fluid slip condition

  • Chun Myung-Suk;Lee Tae Seok;Lee Kangtaek
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.207-215
    • /
    • 2005
  • We present a finite difference solution for electrokinetic flow in rectangular microchannels encompassing Navier's fluid slip phenomena. The externally applied body force originated from between the nonlinear Poisson-Boltzmann field around the channel wall and the flow-induced electric field is employed in the equation of motion. The basic principle of net current conservation is applied in the ion transport. The effects of the slip length and the long-range repulsion upon the velocity profile are examined in conjunction with the friction factor. It is evident that the fluid slip counteracts the effect by the electric double layer and induces a larger flow rate. Particle streak imaging by fluorescent microscope and the data processing method developed ourselves are applied to straight channel designed to allow for flow visualization of dilute latex colloids underlying the condition of simple fluid. The reliability of the velocity profile determined by the flow imaging is justified by comparing with the finite difference solution. We recognized the behavior of fluid slip in velocity profiles at the hydrophobic surface of polydimethylsiloxane wall, from which the slip length was evaluated for different conditions.

Constructing a Three-Dimensional Endothelial Cell Layer in a Circular PDMS Microchannel

  • Choi, Jong Seob;Piao, Yunxian;Kim, Kyung Hoon;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.274.2-274.2
    • /
    • 2013
  • We described a simple and efficient fabrication method for generating microfluidic channels with a circular-cross sectional geometry by exploiting the reflow phenomenon of a thick positive photoresist. Initial rectangular shaped positive photoresist micropatterns on a silicon wafer, which were fabricated by a conventional photolithography process, were converted into a half-circular shape by tuning the temperature to around $105^{\circ}C$. Through optimization of the reflow conditions, we could obtain a perfect circular micropattern of the positive photoresist, and control the diameter in a range from 100 to 400 ${\mu}m$. The resultant convex half-circular photoresist was used as a template for fabricating a concave polydimethylsiloxane (PDMS) through a replica molding process, and a circular PDMS microchannel was produced by bonding two half-circular PDMS layers. A variety of channel dimensions and patterns can be easily prepared, including straight, S-curve, X-, Y-, and T-shapes to mimic an in vivo vascular network. To inform an endothelial cell layer, we cultured primary human umbilical vein endothelial cells (HUVECs) inside circular PDMS microchannels, and demonstrated successful cell adhesion, proliferation, and alignment along the channel.

  • PDF

An Experimental Study of Flow and Dispersion Characteristics in Meandering Channel (사행수로에서의 유속 및 분산특성에 관한 실험적 연구)

  • Park, Sung-Won;Seo, Il-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.799-802
    • /
    • 2008
  • General behaviors based on hydraulic characteristics of natural streams and channels have been recently analyzed and developed via various numerical models. However in the states of natural hydraulics, an experimental research must be performed simultaneously with the mathematical analysis due to effects of hydraulic properties such as meander, sediment, and so on. In this study based on 2-D advection-dispersion equation, flow and tracer experiments were performed in the S-curved meandering laboratory channel with a rectangular cross-section. The channel was equipped with instrument carriages which was equipped with an auto-traversing system to be used with velocity measuring sensors throughout the depth and breadth of the flow field. To measure concentration distribution of the salt solution was adjusted to that of the flume water by adding methanol and a red dye (KMnO4) was added to aid the visualization of the tracer cloud, the tracer was instantaneously injected into the flow as a full-depth vertical line source by the instantaneous injector and the initial concentration of the tracer was 100,000 mg/l. The secondary current as well as the primary flow pattern was analyzed to investigate the flow distribution in the meandering channels. The velocity distribution of the primary flow for all cases skewed toward the inner bank at the first bend, and was almost symmetric at the crossovers, and then shifted toward the inner bank again at the next alternating bend. Thus, one can clearly notice that the maximum velocity occurs taking the shortest course along the channel, irrespective of the flow conditions. The result of the tracer tests shows that pollutant clouds are spreading following the maximum velocity lines in each cases with various mixing patterns like superposition, separation, and stagnation of pollutant clouds. Flow characteristics in each cases performed in this study can be compared with tracer dispersion characteristics with using evaluation of longitudinal and transverse dispersion coefficients(LDC, TDC). As expected, LDC and TDC in meandering parts have been evaluated with increasing distribution and straight parts have effected to evaluate minimum of LDC and TDC due to symmetric flow patterns and attenuations of secondary flow.

  • PDF

Fabrication of a novel micromachined measurement device for temperature distribution measurement in the microchannel (마이크로채널 내의 온도 분포 측정을 위한 미소 측정 구조물의 제작)

  • Park, Ho-Joon;Lim, Geun-Bae;Son, Sang-Young;Song, In-Seob;Pak, James-Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1921-1923
    • /
    • 2001
  • In this work, an array of resistance temperature detector(RTD) was fabricated inside the microchannel in order to investigate in-situ flow characteristics. A rectangular straight microchannel, integrated with RTD's for temperature sensing and a heat source for generating the temperature gradient along the channel. were fabricated with the dimension of $200{\mu}m(W){\times}{\mu}m(D){\times}$48mm(L), while RTD measured precise temperatures at the inside-channel wall. 4" $525{\pm}25{\mu}m$ thick P-type <100> Si wafer was used as a substrate. For the fabrication of RTDs. 5300$\AA$ thick Pt/Ti layer was sputtered on a Pyrex glass wafer. Finally, glass wafer was bonded with Si wafer by anodic bonding, therefore RTD was located inside the microchannel. The temperature distribution inside the fabricated microchannel was obtained from 4 point probe measurements and Dl water is used as a working fluid. Temperature distribution inside the microchannel was measured as a function of mass flow rate and heat flux. As a result, precise temperatures inside the microchannel could be obtained. In conclusion, this novel temperature distribution measurement system will be very useful to the accurate analysis of the flow characteristics in the microchannel.

  • PDF

Convergence of Fluid Dynamics and Computer Simulation for the Internal Investigation of Fuel Cell (유체역학과 컴퓨터 시뮬레이션의 융합을 통한 연료전지의 분석)

  • Kim, Se Hyun
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.245-251
    • /
    • 2016
  • A numerical model is developed to predict distributions of current density and temperature. Also the complete fuel cell performances were compared. In this study the effect of flow field design and flow direction on current density and temperature distribution as well as full cell performance. The complete three-dimensional Navier-Stokes equations were solved with convergence of electro-chemical reactions terms. In this paper, the two different flow field design were simulated, straight channel and rectangular serpentine flow channel, which is commonly used. The effect of flow direction, co-flow and counter-flow, was also analyzed. The current density and temperature is higher with abundant oxygen not fuel. Also, temperature distribution was able to be drawn by using computer simulation. In this paper, the relationship among flow pattern, flow field design and current denstity distribution.

Fabrication of the Microchannel Integrated with the Inner Sensors for Accurate Measuring Fluid Temperature (유체의 정확한 온도 측정을 위하여 내부 센서를 집적한 마이크로채널 제작)

  • Park, Ho-Jun;Im, Geun-Bae;Son, Sang-Yeong;Song, In-Seop;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.449-454
    • /
    • 2002
  • A rectangular straight microchannel, integrated with the resistance temperature detectors(RTDs) for temperature sensing and a micro-heater for generating the Temperature gradient along the channel, was fabricated. Its dimension is 57${\mu}{\textrm}{m}$(H)$\times$200${\mu}{\textrm}{m}$(W)$\times$48,050${\mu}{\textrm}{m}$(L), and RTDs were placed at the inner-channel wall. Si wafer was used as a substrate. For the fabrication of RTDs, 5300$\AA$ thick Pt/Ti layer was sputtered on a Pyrex glass wafer. Finally, the glass wafer was bonded with Si wafer by anodic bonding, so that the RTDs are located inside the microchannel. Temperature coefficient of resistance(TCR) values of the fabricated Pt-RTDs were 2800~2950ppm$^{\circ}C$ and the variation of TCR value In the range of O~10$0^{\circ}C$ was less than 0.3%. Therefore, it was proved that the fabricated Pt-RTDs without annealing were excellent as temperature sensors. The temperature distribution in the microchannel was investigated as a function of mass flow rate and heating power. The temperature increase rate diminished with decreasing the applied power and increasing the mass flow rate. It was confirmed from the comparison with the simulation results that the temperature measured inside the microchannel is more accurate than measuring the temperature measured at the outer wall. The proposed temperature sensing method and microchannel are expected to be useful in microfluidics researches.

Prediction and Measurement of Propagation Path Loss in Underground Environments (지하공간에서의 전파 경로손실의 예측 및 측정)

  • 김영문;진용옥;강명구
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.736-742
    • /
    • 2003
  • This paper presents the propagation path loss in a tunnel which is a kinds of underground environments. To predict propagation path loss more accurately, we choose a straight tunnel with rectangular cross-section. The simulated receiver powers that are using a hybrid waveguide model and a Ray-Tracing method, are compared with the measured ones as a function of distance between TX and RX antennas in tunnel. The attenuation value of regression analysis for measured power in the tunnel is 0.0238dB/m which is similar to the one of the EH1.2 mode, 0.0246dB/m in hybrid waveguide model. By comparing simulation with measurement in tunnels, it has been shown that the measured values are approximate to the simulated results of ray-tracing model. In the analysis of wide-band channel characteristics of the tunnel, the more the distance between TX and RX antennas in tunnel increases, RMS delay spread increases and coherence bandwidth decreases.

Integrated Hybrid Device for High-Efficiency Size-Tunable Particle Separation (고효율 크기 가변적 입자 분리를 위한 통합 하이브리드 소자)

  • Choo, Seung Hee;Park, Jion;Kim, Tae Eun;Gang, Tae Gyeoung;An, Jun Seok;Oh, Gayeong;Kim, Yeojin;Park, Kyu Been;Park, Chaewon;Lee, Minjeong;Lim, Hyunjung;Nam, Jeonghun
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.170-176
    • /
    • 2022
  • Cell separation from a heterogenous mixture sample is an essential process for downstream analysis in biological, chemical, and clinical applications. This study demonstrates an integrated hybrid device of the viscoelastic focusing in a straight rectangular channel and subsequent size-based separation using acoustophoresis to attain high efficiency and separation tunability. For particle pre-alignment in a viscoelastic fluid, the flow rate higher than 10 μl/min was required. Surface acoustic wave-based lateral migration of particles with different sizes (13 and 27 ㎛) was examined at various applied voltages and flow rate conditions. Therefore, the flow rate of 100 μl/min and the applied voltage of 20 Vpp can be used for size-based particle separation.