• 제목/요약/키워드: Storm loading

검색결과 76건 처리시간 0.029초

LIDMOD2 Development for Evaluation of LID/BMPs (LID/BMPs 효과분석을 위한 LIDMOD2 개발)

  • Jeon, Ji-Hong;Choi, Donghyuk;Na, Eun Hye;Park, Chan-Gi;Kim, Tae-Dong
    • Journal of Korean Society on Water Environment
    • /
    • 제26권3호
    • /
    • pp.432-438
    • /
    • 2010
  • LIDMOD2 was developed for evaluation of low impact development (LID) and best management practice (BMP) by modification of Site Evaluation Tool (SET). The modification includes employment of SCS-CN method for annual runoff simulation, unit load method for annual pollutant loads simulation, and the method proposed by Korean TMDL for calculating pollutant reduction by BMPs. The CN values were updated with regionalized parameters within Nack-Dong River basin because these are important parameters for simulating hydrology. LIDMOD2 was tested by applying to Andong Bus terminal. As a simulation results, pollutant loads and surface runoff will be significantly increased by post-development without LID compared with those from pre-development. LID technique was simulated to efficiently reduce surface runoff and pollutant load and increase infiltration. LIDMOD2 is screening level tool and easy to use because LIDMOD2 is based on spread sheet and most of parameters are regionalized. LIDMOD2 was illustrate that it could evaluate LID well by summarizing and graphing annual hydrology, annual pollutant loading, and hydrograph for event storm. The calculation methods related with pollutant loads are employed from the guideline of Korean TMDL and it can be useful tool for Korean TMDL to evaluate the effect of LID/BMP on developing area.

Bow Structure Design of the FPSO installed in the North Sea under the Flare Slamming Load (북해설치 FPSO의 플레어 슬래밍 하중에 대응한 선수 설계)

  • Kim, Ul-Nyeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제52권5호
    • /
    • pp.418-424
    • /
    • 2015
  • This paper is about the bow structure design of the ship-typed and turret moored FPSO which is subjected to the bow-flare slamming load in harsh North Sea environments. Quad 204 FPSO project involves the redevelopment of the existing Schiehallion FPSO which is damaged by impact wave loads. Normally all offshore systems including FPSO are designed to withstand the 100 year storm I.e. the storm that happens once every hundred years at the location where the system is installed. Several incidents have revealed that impact loading is important issue for moored floating production systems. In this paper, the design impact loads are estimated considering the ship owner’s specification, measured data from model tests, requirements of the classification society rules and results of numerical simulation analyses. The impact pressure by numerical analysis is 1.8 times greater than required value by CSR adopted by IACS. Based on the selected design load, plastic design formulae allowing the local material yielding are applied for the initial scantling of the bow structure. To verify the structural integrity, FE analyses are carried out considering the local area subjected to the impact wave loads. Their results such as structural arrangement, design loads and scantlings are shown and discussed. It is found that plastic design formulae in adopting Initial design phase give sufficiently conservative results in terms of structural strength.

Characteristics of Washed-off Pollutants from Railway Station During Storms (강우시 철로 역사에서 발생하는 비점오염물질의 유출 경향 및 특성)

  • Kim Lee-Hyung;Oa Sunguk;Lee Seonha
    • Journal of the Korean Society for Railway
    • /
    • 제8권1호
    • /
    • pp.15-20
    • /
    • 2005
  • The ministry of Environment, Korea, are designing the TMDL(Total Maximum daily Load) program far 4 major large rivers to improve water quality from possible pollutants. It can be successfully performed as controling of nonpoint pollutants from watershed area. Railway stations are stormwater intensive land use because of high imperviousness and high pollutant mass emissions from various activities. Especially the metal pollutants from the railway station were recognized as an important pollutants because of its toxicities. In order to characterize the washed-off pollutants. the monitoring were performed on a railway station during storms. Pollutant concentrations are exponentially decreasing during the storm duration. The 95% confidence interval of pollutant concentrations in an hour storm duration ranges from 61.6 to 115.4mg/L for TSS(mean=88.50mg/L),103.8-244.1mg/L for COD(mean=174 mg/L) and 7.68-17.32mg/L for Oil & Grease(mean=12.5mg/L). The ranges of metals were 39.2-84.0 $\mu\textrm{g}$/L for total Cu(mean=61.6$\mu\textrm{g}$/L), 14.0-25.8$\mu\textrm{g}$/L for total Pb(mean=19.9$\mu\textrm{g}$/L) and 182.2-376.l $\mu\textrm{g}$/L for total Zn(mean=279.2$\mu\textrm{g}$/L). The first flush criteria for best management practices can be suggested to 50% pollutant mass emissions during 30% of the total flow.

Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles (역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제34권10호
    • /
    • pp.694-701
    • /
    • 2012
  • The main purpose of this study is to evaluate of backwash system of hydrodynamic separator filter (HSF) with solar powered submerged pumps. It consists of a photovoltaic solar array, control electronics, battery, and two submersible pump powered by a 12 voltage DC motor. The laboratory scale study on treatable potential of micro particles using backwash HSF that was a combined with perlite filter cartridge and backwash nozzles. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particle sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin partices, silica gel particles, and commercial area manhole sediment particles. HSF was made of acryl resin with 250 mm of diameter filter chamber and overall height of 800 mm. Four case test were performed with different backwashing conditions and determined the SS removal efficiency with various surface loading rates. The operated range of surface loading rate was about 308~$1,250m^3/m^2/day$. It was found that SS removal efficiency of HSF using two submersible pumps improved by about 18% compared with HSF without backwash. Nonpoint control devices with solar water pumping systems would be useful for backwashing the filter in areas with not suppling electricity and reduce filter media exchange cost.

Determination of Heavy Metal Unit Load from Transportation Landuses during a Storm (교통 관련 토지이용에서의 중금속 오염원단위 산정)

  • Kim, Cheol-Min;Lee, So-Young;Lee, Eun-Ju;Kim, Lee-Hyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제8권6호
    • /
    • pp.155-160
    • /
    • 2008
  • The urban areas have various landuses such as residential, commercial, industrial and official purposes that are highly concerned with human activities. The other landuses are relating to vehicle activities, which are roads, parking lots, bridges, parks etc. The mainly using landuses by human activities are possessing three different areas that are buildings, parking lots/roads and landscapes. Of these areas, the buildings and landscapes can be classified as non-pollution areas. However, the parking lots or roads are classifying as the main pollution areas because of vehicle activities. Therefore, the landuses arising the nonpoint pollution during a storm in urban areas are roads and parking lots. The vehicles are emitting lots of nonpoint pollutants such as metals and particulate matters and it is impacting on water qualities and aqua-ecosystems nearby the city areas. Therefore, this research was conducted for characterizing the pollutant types and determining the EMCs (Event Mean Concentrations) and unit pollutant loads during a storm. The monitoring was performed on 9 locations such as highways, service area, tollgates, parking lot and bridges. All of the landuses selected for monitoring are concerned with transportation. The results can be effectively used to predict the pollutant loading before urban planning and to select the BMPs (Best Management Practices) for reducing the pollution.

NPS Control in Environment-kindly Resort Development: Determination of NPS Loading Rates by BMPs (친환경 리조트 개발사업을 위한 비점오염원관리: 비점저감시설을 통한 오염물질 삭감량 산정)

  • Lee, Eun-Ju;Jung, Yong-Jun;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • 제9권2호
    • /
    • pp.9-20
    • /
    • 2007
  • The nonpoint pollutants are originated from various land uses. Of the landuses, the development means the changes of the soil cover and the increases of imperviousness rate, which will increase the nonpoint pollutant emissions during a storm. Therefore, the Ministry of Environment in Korea has programed TPLMS(Total Pollution Load Management System) for four major large rivers to improve the water quality in rivers by controling the total pollutant loadings from the watershed area. The study area was forest landuse before resort development, however it is now changing to the resort. Some of the forest areas will be changed to parking lots, roads and buildings, which can be the major pollutant sources in the future. The paved areas are highly polluted landuses because of high pollutant accumulation rate by vehicle activities during dry periods. Therefore, this research is achieved to determine the changes of pollutant loading rate by development plan and to provide the best management practices for controlling nonpoint pollutants. Finally this research will provide the environment-kindly development technology for protecting the water quality.

  • PDF

Changes of NPS Loading Rates by Landuse Changes in Resort Development (리조트 개발사업에서 토지이용 변화에 따른 비점오염물질 부하량 변동 산정)

  • Jung, Yong-Jun;Lee, Eun-Ju;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • 제8권4호
    • /
    • pp.23-31
    • /
    • 2006
  • The nonpoint pollutants are originated from various land uses. Of the landuses, the development means the changes of the soil cover and the increases of imperviousness rate, which will increase the nonpoint pollutant emissions during a storm. Therefore, the Ministry of Environment in Korea has programed TPLMS(Total Pollution Load Management System) for four major large rivers to improve the water quality in rivers by controling the total pollutant loadings from the watershed area. The study area was forest landuse before development plan, however it is now changing to the resort. Some of the forest areas will be changed to parking lots, roads and buildings. The paved areas are highly polluted landuses because of high pollutant accumulation rate by vehicle activities during dry periods. Therefore, this research is achieved to determine the changes of pollutant loading rate by development plan and to provide the best management practices for controlling nonpoint pollutants.

  • PDF

Effect of Stormwater Runoff on Combined Sewer Overflows in Korea

  • Kim, Lee-Hyung;Kim, Il-Kyu;Lee, Young-Sin;Lim, Kyeong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제7권4호
    • /
    • pp.107-113
    • /
    • 2007
  • The Kuem-River, one of the largest rivers in Korea, is the primary water source for more than 4 million people in Kongju city and surrounding area. To study the effect of stormwater runoff to CSOs, twelve monitoring sites were selected in two large cities (City of Kongju and City of Buyeo) near the Kuem-River. Monitoring was reformed by collecting grab samples, measuring flow rates during dry and wet seasons during over two rainy seasons. Generally the flow rate of wastewater in combined sewers was rapidly decreased after 23:00 P.M. and gradually increased from 06:30 A.M. in all sites during the dry season. The concentrations of pollutant increase approximately 5 to 7 fold for TSS and 1.5 to 2.5 fold for BOD during the rainy season. Monitoring and statistical analysis show that the groundwater contributes on sewage volume increase (average 25-45% more) during dry periods and the stormwater runoff contributes approximately 51-72% increase during rainy periods. Generally the concentrations of combined sewage were more polluted during the first flush period than after the first flush during a storm event.

Application of FE approach to deformation analysis of RC elements under direct tension

  • Jakubovskis, Ronaldas;Kupliauskas, Rimantas;Rimkus, Arvydas;Gribniak, Viktor
    • Structural Engineering and Mechanics
    • /
    • 제68권3호
    • /
    • pp.345-358
    • /
    • 2018
  • Heterogeneous structure and, particularly, low resistance to tension stresses leads to different mechanical properties of the concrete in different loading situations. To solve this problem, the tension zone of concrete elements is reinforced. Development of the cracks, however, becomes even more complicated in the presence of bar reinforcement. Direct tension test is the common layout for analyzing mechanical properties of reinforced concrete. This study investigates scatter of the test results related with arrangement of bar reinforcement. It employs results of six elements with square $60{\times}60mm$ cross-section reinforced with one or four 5 mm bars. Differently to the common research practice (limited to the average deformation response), this study presents recordings of numerous strain gauges, which allows to monitor/assess evolution of the deformations during the test. A simple procedure for variation assessment of elasticity modulus of the concrete is proposed. The variation analysis reveals different deformation behavior of the concrete in the prisms with different distribution of the reinforcement bars. Application of finite element approach to carefully collected experimental data has revealed the effects, which were neglected during the test results interpretation stage.

Reliability Analysis of Offshore Guyed Tower Against Anchor Pile Failures (해양 가이드-타워의 고정말뚝에 대한 신뢰도 해석)

  • 류정선;윤정방;강성후
    • Computational Structural Engineering
    • /
    • 제4권3호
    • /
    • pp.117-127
    • /
    • 1991
  • For the reliability analysis of offshore guyed towers for large storm events, failure of an anchor pile of the guyline system is investigated. Two failure modes of the anchor pile due to the extreme and the cyclic wave loadings are considered. The probability of failure due to the extreme anchor load is evaluated based on the first excursion probability analysis. Degradation of the pile capacity due to cyclic loadings is evaluated by using empirical fatigue curves for a driven pile in clay. The numerical results indicate that the failure probability due to the cyclic loadings can be as large as the risk due to extreme loading, particularly for the cases with the low design safety level of the pile strength and the large uncertainty of the pile resistance.

  • PDF