• Title/Summary/Keyword: Storage type

Search Result 1,982, Processing Time 0.031 seconds

Design of a Small Form Factor Swing Arm type Actuator using Design of Experiments (실험계획법을 이용한 초소형 스윙암 액추에이터의 설계)

  • Park Chul;Yoo Jeong-Hoon;Park No-Ceol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.813-819
    • /
    • 2006
  • The state of the art for the design of swing ann actuators for optical disc drives is to obtain the high efficient dynamic characteristics, especially for the small size for the mobile information devices, It is affected by the need of consumers who wants the portable digital storage devices maintaining highly functional and removable characteristics of the optical disk drive (ODD). As a necessary consequence, the need of the small form factor (SFF) storage device has been considered as an important part in the information storage technology. In this paper. we suggest a new conceptual miniaturized swing arm type actuator that has high efficient dynamic characteristics as well as satisfies the sensitivity and the heat emission requirements for the SFF-ODD. It also uses a tracking electromagnetic (EM) circuit for a focusing motion. Due to the size constraint, the thermal problem of optical head arises; therefore, we design an efficiently heat emitted structure for the actuator.

  • PDF

A Study on Thermal Stratification Characteristics and Useful Rate of Hot Water in Thermal Storage Tank during Hot Water Extraction Process (온수 추출과정 동안 축열조 내의 열성층 특성 및 온수 이용률에 관한 연구)

  • 장영근;박정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.503-511
    • /
    • 2002
  • Heat flow characteristics during hot water extraction process was studied experimentally. Data were taken at various outlet port type for the fixed inlet port type, inlet-outlet temperature differences and mass flow rates. In this study, the temperature distribution in a storage tank and an outlet temperature were measured to predict a degree of stratification in the storage tank, and a useful rate of hot water was analysed with respect to the variables dominating a extraction process. Experimental results show that the degree of stratification and useful rate of hot water are all high in a low flow rate in case of using modified distributor I (MDI) as the outlet port type.

Study on Heat Transfer Characteristics of Screen Type Heat Storage Materials (집강형 축열재의 열전달 특성에 관한 연구)

  • Pak, Hi-Yong;Park, Woong-Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.2
    • /
    • pp.81-89
    • /
    • 1981
  • Experimental results for convective heat transfer from a number of screen type heat storage materials, made of stainless steel and brass, were obtained by the use of the transient technique. The effects of the material, the size of mesh, and the number of screens. on the heat transfer coefficient could not be detectable A dimensionless correlation describing the convective heat transfer from the screen type heat storage materials is given in the range of Reynolds number between 60 and 1000.

  • PDF

A Numerical Study on the Hoop Tensile Test of Type IV High Aspect Ratio Hydrogen Storage Vessel (Type IV 고세장비 수소저장용기의 Hoop 인장 시험에 관한 수치해석적 연구)

  • MOONSIC PARK;JUNSOONG LEE;WONHO YOON;KYUNBUM PARK;HYEONGUK YUN;SUNGWOOK JOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.1
    • /
    • pp.32-37
    • /
    • 2023
  • In this study, in order to propose a integrity evaluation for type IV high aspect ratio hydrogen storage vessel, a numerical analysis of the hoop tensile test and pressure test was performed using FEM software, and the results of the actual physical property test were reviewed. The property test and numerical analysis were compared, and very similar results were obtained with deviations of maximum tensile strength of 4.75% and fiber direction stress of 5.39%.

Seismic Behavior of Liquid Storage Tanks Using Complex and Simple Analytical Models

  • Nabin, Raj Chaulagain;Sun, Chang Ho;Kim, Ick Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.401-409
    • /
    • 2018
  • Performance-based seismic evaluation is usually done by considering simplified models for the liquid storage tanks therefore, it is important to validate those simplified models before conducting such evaluation. The purpose of this study is to compare the seismic response results of the FSI (fluid-structure interaction) model and the simplified models for the cylindrical liquid storage tanks and to verify the applicability of the simplified models for estimating failure probability. Seismic analyses were carried out for two types of storage tanks with different aspect ratios (H/D) of 0.45 and 0.86. FSI model represents detailed 3D fluid-structure interaction model and simplified models are modeled as cantilever mass-spring model, frame type mass-spring model and shell type mass-spring model, considering impulsive and convective components. Seismic analyses were performed with modal analysis followed by time history analysis. Analysis results from all the models were verified by comparing with the results calculated by the code and literature. The results from simplified models show good agreement with the ones from detailed FSI model and calculated results from code and literature, confirming that all three types of simplified models are very valid for conducting failure probability analysis of the cylindrical liquid storage tanks.

The Checklist Based on Stored items of Cooking for Kitchen Furniture Design (부엌가구디자인 효율화를 위한 식생활물품 체크리스트)

  • Kim, Sun-Joong;Kwon, Myung-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.53-65
    • /
    • 2010
  • The purpose of this study is to develop a checklist based on the stored items of cooking, for making a good kitchen furniture reseach. The research candidates are purposive sampled from 30 households of for 40 or 50 pyeong-type apartments in Kangnam, Seoul, The research data are is collected gotten at by a field study of the stored items of cooking, eating and utility area, by an in-depth interview to 30 households, and by a field survey of the department stores, super-markets of home appliances. Studied households in average hold about 890 items, which are classified as 239 sorts. The first step of making the checklist is to categorize items into 9 biggest categories, considering the usage of items and the stage of the preparing the food. when the item was used. Second step of making the checklist is to categorize the items into 31 smaller categories, which reflect the shape of items, the storage style and the place of storage. Third step of making the checklist is to sort the items into smallest categories by the frequency of the usage, storage type, and the additional capacity of the item. Even Although items are sorted into the same level of categories, the frequency of use make a different storage area. Also, the storage style of the items was different according to the storage area. Based on these factors, we suggested a checklist based on the stored items of cooking.

Heat Transfer Characteristics and Hydrogen Storage Kinetics of Metal Hydride-Expended Graphite Composite (금속수소화물-팽창흑연 복합체의 열전달 특성 및 수소 저장 특성)

  • LEE, PYOUNGJONG;KIM, JONGWON;BAE, KIKWANG;JEONG, SEONGUK;KANG, KYOUNGSOO;JUNG, KWANGJIN;PARK, CHUSIK;KIM, YOUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.564-570
    • /
    • 2020
  • Metal hydride is suitable for safe storage of hydrogen. The hydrogen storage kinetics of the metal hydride are highly dependent on its heat transfer characteristics. This study presents a metal hydride-expended graphite composite with improved thermal conductivity and its hydrogen storage kinetics. To improve the heat transfer characteristics, a metal hydride was mixed and compacted with a high thermal conductivity additive. As the hydrogen storage material, AB5 type metal hydride La0.9Ce0.1Ni5 was used. As an additive, flakes-type expended graphite was used. With improved heat transfer characteristics, the metal hydride-expended graphite composite stores hydrogen four times faster than metal hydride powder.

Design of Magnetic Levitating Flywheel Energy Storage System (자기부상형 플라이휠 에너지 저장 장치의 자기베어링 시스템 설계)

  • Yoo, S.;Mo, S.;Choi, S.;Lee, J.;Han, Y.;Noh, M.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.963-967
    • /
    • 2007
  • Flywheel energy storage systems (FESS) have advantages over other types of energy storage methods due to their infinite charge/discharge cycles and environmental friendliness. The system has two radial bearings and one hybrid-thrust bearing. Thrust hybrid-type bearing use permanent magnet to relieve gravity load. The radial bearings were designed to provide sufficient force slew rate considering the unbalance disturbance at the operating speeds. In this paper, we will derive dynamic model of hybrid-type bearing using permanent magnet for thrust bearing and present simulation and stability of the model.

  • PDF

Measurement of Irrigation water-reuse ratio for pumped storage system (양수저류시스템의 반복이용률 측정)

  • Park, Ji-Sung;Kim, Young-Hwa;Lee, Young-Il;Kim, Pil-Dong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.295-298
    • /
    • 2003
  • In this study, It classified type of irrigation water development in islands district. As result, the types which were type of reservior, fleshwater lake, pumped storage, ets. Most of islands district has developed reuse irrigation system as a pumped storage system. But, Irrigation water-reuse ratio doesn't define a basis clearly and the value of measurement for water-reuse ratio doesn't exist so far. so, we measured Irrigation water-reuse to clarify for water-reuse ratio in a pumped storage system.

  • PDF

Modeling and Optimization of Rice Drying and Storage System in Korea(I) -Layout and Design of Model System- (한국에 있어서 미곡(米穀)의 건조(乾燥) 및 저장(貯藏)을 위한 시스템의 모델 개발 및 적정규모 선정에 관한 연구(I) -모델 시스템의 Layout 및 설계-)

  • Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.11 no.2
    • /
    • pp.66-75
    • /
    • 1986
  • In order to improve the traditional post harvest system in Korea, a model for mechanized grain drying and storage facilities was developed. Also, a computer program for the model system was developed. For the study, flat type steel bin and circulation type dryer were selected for the model and Fortran language was used for the computer program. This program was tested by using various practical data. The following results were obtained from the study: 1. The general model developed can be used for designing a rough rice drying and storage facility within the range from 100 ton to 1000 ton capacity. 2. Major output of the computer program for designing a model system were as follow; a. The dimension of the plant. b. The storage bin size, dryer number and dryer size. c. The dimension of individual equipment and its required HP. d. Capital requirement and operating cost of the model system.

  • PDF