• 제목/요약/키워드: Storage plan

검색결과 446건 처리시간 0.022초

Analysis of Characteristics of Spent Fuels on Long-Term Dry Storage Condition

  • Yoon, Suji;Park, Kwangheon;Yun, Hyungju
    • 방사성폐기물학회지
    • /
    • 제19권2호
    • /
    • pp.205-214
    • /
    • 2021
  • Currently, the interim storage pools of spent fuels in South Korea are expected to become saturated from 2024. It is required to prepare an operation plan of a domestic dry storage facility during a long-term period, with the researches on safety evaluation methods. This study modified the FRAPCON code to predict the spent fuel integrity evaluation such as the axial cladding temperature, the hoop stress and hydrogen distribution in dry storage. The cladding temperature in dry storage was calculated using the COBRA-SFS code with the burnup information which was calculated using the FRAPCON code. The hoop stress was calculated using the ideal gas equation with spent fuel information such as rod internal pressure. Numerical analysis method was used to calculate the degree of hydrogen diffusion according to the hydrogen concentration and temperature distribution during a dry storage period. Before 50 years of dry storage, the cladding temperature and hoop stress decreased rapidly. However, after 50 years, they decreased gradually and the cladding temperature was below 400 K. The initial temperature distribution and hydrogen concentration showed a parabolic line, but hydrogen was transferred by the hydrogen concentration and temperature gradient over time.

경수로 사용후핵연료 중간저장시설 개념(안) 수립 (Conceptual Design of Interim Storage Facility for PWR Spent Nuclear Fuel)

  • 강현구;이상환;신창민;문태철
    • 방사선산업학회지
    • /
    • 제18권3호
    • /
    • pp.255-266
    • /
    • 2024
  • The uranium nuclear fuel used in nuclear power generation needs to be replaced with new fuel after a certain period. In South Korea, the spent nuclear fuel generated during this process is temporarily stored within the nuclear power plant site, and there are ongoing issues with the saturation of storage capacity. To address these problems, the South Korea government has established a plan to manage high-level radioactive waste, including provisions for securing interim storage facilities. An interim storage facility is designed to safely store spent nuclear fuel for certain period before its permanent disposal. This study analyzed leading international cases of interim storage facilities that are technically feasible and can reduce the operating period of temporary storage facilities for spent nuclear fuel within nuclear power plant sites. It also presented the technical concepts required for the operation of interim storage facilities for spent fuel from PWR(Pressurized Water Reactor), reflecting the situation in South Korea.

아파트 규모별 수납 실태 및 거주자 요구 조사 (A Study on Residents' Needs for Storage According to Unit Size in Apartment)

  • 이지순;최연진;박지현;윤정숙
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.101-110
    • /
    • 2002
  • The purpose of this study was to examine needs of residents on the storage according to unit size in apartment. In order to achieve our goal, the questionnaire survey was used. We sampled the questionnaire surveys of 250 households in Seoul whose apartment sizes had been more than 20 pyung. The data collected by the questionnaire survey was analyzed by examining the frequency, percentage on the SPSS/PC+. The results of the study were obtained as follows: 1) In research on the actual storage condition, Residents tended to feel constraint on the storage of the season goods and the storage satisfaction on the service area was found lowest. Therefore, there needed to design the balcony more efficiently for the storage and the interior storage for the season goods. 2) In research on consciousness and attitude about the storage, residents tended to keep the goods of no use and prefered to arrange neatly rather than use conveniently. Therefore, there needed more efficient space in the balcony for the storage of the goods of no use and the closed furniture rather than the open furniture was suited for arrangement. 3) In research on the storage needs, needs for the built-in furniture in all apartment sizes showed highly and residents wanted a space for the exclusive use of the storage. In a solution, it was proposed to equip with the interior storage and the exterior cooperative storage. In the conclusion, needs of residents on the storage according to apartment size were different little. The small size apartment had the serious storage problems and wanted the efficient space plan for storage.

수술부 리모델링을 통한 공간구성 변화에 관한 연구 (A Study on the Area Composition of the Operating Unit After Remodeling)

  • 김길채
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.

공간 차별화 계획을 위한 공동주택 단위주호의 평면계획 특성 분석 (Current Features of Apartment House Unit Plans towards Spatial Differentiation)

  • 박소윤;이현수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.352-356
    • /
    • 2006
  • This study aims to analyze the current status and characteristics of apartment house unit plans towards spatial differentiation. The 172 house units from 32 housing complexes were selected for this analysis. In this study, factors of residential space plan especially in an apartment house are categorized into general characteristics on floor plan and factors for spatial floor plan. The Primary findings are as follows: (1) General characteristics on floor plan are analyzed based on space organization, area and number of bays. Among apartment houses over 40 pyeong, it seems that differentiation is well applied with various space plans available. (2) A result of an analysis on the factors for spatial floor plan shows that planning a living room with two-open-sides seems to be more common in the tower-shaped apartment blocks which are now on the increase. Moreover, many of them are adopting movable partitions to reflect resident's various demands on space plan. Among all, the extra kitchen in the balcony is planned high portion of 80.4%. And diningroom is positioned on the front side of the residential space along with a livingroom(19.2%). More frequently, dining area tends to face the living room(30.2%) according to the result. Besides dress rooms begin to be placed in each of the bedroom, once planned in one bedroom only while 18.6% of the apartment houses are placing new storages in the entrance to solve lack of storage space due to balcony extension.

  • PDF

용담댐 관리계획이 대청댐 저수량에 미치는 영향 (Impacts of Yongdam dam managment Plan on Daechung dam Storage)

  • 박정남;이재면;김태얼
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.550-555
    • /
    • 1999
  • yongdam multipurpose is under construction to divert a part fo Geum riverlfow to Mankyung watershed and to supply the domestic water to the Chunju region and produce the hydro-electricity. Generally construction of dam by the method of inther-region water transfer affects the quantity and quality of water inthe down streams and reservoirs. The impact of operation plan of Yondgam dam on the quantity and quality of water in the Guem river and Daechung dam was investigated .It was recommended that the discharge of water transfer from one watershed to another should be minimized as much as possible.

  • PDF

도서지역 양수저류 관개지구의 모니터링 및 수문모델 적용 (Application of hydrology model and Monitoring on pumped-storage section in islands district)

  • 김영화;박지성;이영일;한국헌;김채수
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.215-219
    • /
    • 2004
  • In this study, Types of irrigation water development in islands district were classified. The types were reservior, fleshwater lake, pumped storage, etc. Most of islands district has delveloped reuse irrigation system as a pumped storage system. But. Irrigation water-reuse ratio doesn't define a basis clearly and the value of measurement for water-reuse ratio doesn't exist so far. so, we measured Irrigation water-reuse to clarify for water-reuse ratio in a pumped storage system. Also, we need to develop hydrologic analysis and water balance method with characteristic factor of islands district. that make use of plan about security of agriculture water efficiently in islands district.

  • PDF

산지유역에서의 최적용수공급방안에 관한 연구 (A Study of Optimal Water Supply Planning in Mountainous Area)

  • 김지학;박기범
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.967-973
    • /
    • 2006
  • In this study used tank model and specific discharge to calculate low-flow of mountain basin and supply data that need in water resources plan. Low-flow is calculated byspecific discharge and area ratio method as resulted that calculate storage of low-flow by tank model was construed that showd all similar aspect. In judged to help in water resources plan establishment calculating low-flow using model to supplement uncertainty of observed data in that calculate of low-flow ungaged mountain area. It shows by economical and realistic plan until 12 years after development that run parallel and use economic performance analysis result valley flow and groundwater. But wide area water services and Chungju dam since 12 years onward was expose that is economic.

공동주택 세대외부창고의 활성화 방안을 위한 사례 연구 (A Case Study on Active Usage of the Storage Space Outside Housing Unit of Residential Complex)

  • 송지현;이현수
    • 한국실내디자인학회논문집
    • /
    • 제27권1호
    • /
    • pp.58-67
    • /
    • 2018
  • This study aims to analyze the cases of storage space outside housing unit and propose the activation plan. The issue of storage in residential complex has continued to be reported. This is more salient due to the recent preference trend for small houses, the constant increase of living goods and the limitation of the available space inside housing unit. Although more apartment houses are trying to have individual storage in the exterior space to address these issues, there is still a paucity of the related studies and more studies are required. In this study, we conducted on-site investigation and user interview of each case to propose active usage of the storage space outside housing unit. Result of this study shows that the most crucial factor to improve is 'accessibility' in order to activate the storage space. Storage room should be located close to each household or the individual parking space. The second factor is the size and the structure of the storage room. The sufficient space for keeping and taking large objects out are required. The front of the storage room should have a clogged structure to insure privacy. The third is the provision of suitable support programs such as the system that occupants can check remotely what items are in their storage rooms, garage sale, laundry service, auto cleaning system and rental program. Those programs are required for efficient management and activation of space. Another requirement is to improve environmental factors which include maintenance of optimal temperature and humidity, automatic ventilation system, control of individual lights, and security enhancement. Based on the results of the survey, we provide basic data which can be used for practical space planning to activate exterior storage space of the housing unit. Further surveys are required to develop this study by obtaining more data for generalization.

연근해 어선용 해수냉각장치의 열부하특성 (Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF