• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.033 seconds

The National Policy of Information Management in the U.K. (영국의 문헌정보관리 정책)

  • Han, S.W.
    • Journal of the Korean Society for information Management
    • /
    • v.4 no.2
    • /
    • pp.31-46
    • /
    • 1987
  • The United Kingdom has a well-developed and comprehensive information infrastructure which has grown up over many years, but in the strict sense it has no coherent body of policy relating to information collection, storage, provision and supply. However, each of the governmental, professional and other bodies which has any major involvement with information, has committees to run its affairs and develop its policies in relation to issues and problems in the field. In addition, a number of ad hoc committees and working parties, to discuss or deal with a current problem, or to monitor or advise on the conduct of a research or development project, show that there is a high degree of awareness. of what is happening in the field and that there are many opportunities for expressing any particular point of view. The need for good intelligence in business or industrial operations is now being more generally accepted, and in consequence the need for a director of intelligence is also seen. The director of information in an industrial setting is the information manager, who combines or has access to the skills of several disciplines, including library, data processing and communication skills as well as managerial. Recognition of the need for such persons has policy implications in terms of short-term training provision and long-term educational facilities for the emerging profession, as well as manpower planning implications.

  • PDF

Design Development of Variable Interior Lighting Applying the Concept of Module (모듈개념을 적용한 가변형 실내조명 디자인개발)

  • Lee, Seungheon;Kim, KieSu
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.28-37
    • /
    • 2018
  • It is necessary to produce and maintain interior lighting design reasonably and actively. Based on the lighting design applicable to interior design, the purpose of this study is to take into consideration the public design of public facilities installed in neighborhood parks and thereby to suggest a module-type variable interior lighting product design for reasonable use. To achieve that, relevant studies were reviewed to find the basic concepts of a module and the best cases of interior lighting applicable to interior design. To draw a new concept of the lighting design to which the concept of a module is applied, this study suggested the design direction for practical product development and a module-type design featuring easy process, product storage, assembly, and management, analyzed the reasonable maintenance direction for the development of lighting design, and proposed a case of design development applicable to the development of a new product design. Through cognitive strategy process, the design was made. This process, as a conceptual strategy, included the step of interior environment analysis, the step of lighting maintenance, the step of variable mechanism, and the step of emotional activation. These steps were connected with formative beauty of design so as to suggest a MLD(Module Lamp Design) strategy. In this way, this study tried to connect humans' free application for a space to a module product and to apply humans' visual approach and free conceptual value to MLD cognitive strategy design process for development.

Study on Safety Management Plan through Chemical Accident Investigation in PCB Manufacturing Facility Etching Process (PCB 제조시설 에칭공정 화학사고 조사를 통한 안전관리 방안 연구)

  • Park, Choon-Hwa;Kim, Hyun-Sub;Jeon, Byeong-Han;Kim, Duk-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.132-137
    • /
    • 2018
  • Although the number of chemical accidents has been declining since the Chemical Control Act of 2015, there have been repeated occurrences of similar types of accidents at printed circuit board (PCB) manufacturing facilities. These accidents were caused by the overflow of hydrochloric acid and hydrogen peroxide, which are toxic chemicals used in the printed circuit board manufacturing process. An analysis of the $Cl^-$ content to identify the cause of the accident showed that in the mixed route of hydrochloric acid and hydrogen peroxide, which are accidental substances, the $Cl^-$ concentration was 66.85 ppm in the hydrogen peroxide sample. Through reaction experiments, it was confirmed that the deformation of a PVC storage tank and generation of chlorine gas, which is a toxic gas, occurred due to reaction heat occurring up to $50.5^{\circ}C$. This paper proposes a facility safety management plan, including overcharge, overflow prevention, leak detection device, and separation tank design for mixing prevention in printed circuit board manufacturing facility etch process. To prevent the recurrence of accidents of the same type, the necessity of a periodic facility safety inspection and strengthening of the safety education of workers was discussed.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

A Study on the Development of Intelligent Markup Indicator (IMI) Technology for Underground Facilities Management Using IoT (IoT를 이용한 지하매설물관리용 지능형표지기(IMI) 기술개발에 관한 연구)

  • Kim, Tai-Dal
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.129-136
    • /
    • 2017
  • Geographic Information System The geographic information system (GIS) has been limited to the government and some public sectors. Recently, the market has been diversified by combining with other areas such as mobile and CRM (Customer Relationship Management). The development direction of GIS technology in the 21st century is Web GIS, 3D GIS, mobile GIS, LBS, etc. as general technology for GIS application system development and spatial information service. In this study, we developed a new concept marking nail (a marking nail with built - in intelligent storage memory device) from the function of simple positioning of a marking nail related to a previously used underground item,, Burial depth, pipe thickness, piping material, management agency, contractor, contact, etc.) and store it in DB server, if necessary.Make it available in the right place. Through this research, it is possible to prevent and minimize various accidents caused by irregular excavation works, etc., and to provide information for establishing countermeasures related to sink holes. In order to provide systematic and reliable information on underground burial management, it was proposed to input information conveniently in the field, and the purpose was to reduce the incidence of buried underground pipes absolutely.

A Case Study of Calculating Flood Inundation Area by HEC-GeoRAS (HEC-GeoRAS 모형에 의한 침수면적산정 사례연구)

  • Kim, Chang-Soo;Lee, Young-Dai;Lee, Hwan-Woo
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.43-48
    • /
    • 2009
  • During the past few years, Korea has experienced extraordinary floods, which have caused many damages of lives and properties. Flooding caused by typhoon is the most common disastrous phenomenon of nature among all catastrophes. As the average temperature of the earth has been increasing by global warming, the possibility of typhoon is also increased by abnormal climate changes. Along with the river improvement as a part of flood control, the time of concentration has been decreased, so the pick discharge has been increased. Moreover, with the land development activities, the area of storage has been diminishing, and the damages from inundation have been continuously increasing. There were a lot of damages to farmland in 1960's, industrial and public facilities in 1970's, and a lot of sufferings from the windstorm in 1980's. In 1990's, however, the amount of damages was increased substantially. So, there is need to decrease the number of the victims and loss of properties by applying preventive measures against natural calamities. This study has employed a simulation system to calculate the depth and amounts of inundation areas to forecast and prevent from flood damage by using rainfall-runoff model. In this study, a case study method is adopted to show inundation by using rainfall-runoff model, HEC-GeoRAS and Arcview. It is hoped that, this study would be conducive to professionals and organizations working in the field of disaster management.

  • PDF

Towards efficient policies for soil pollution prevention and remediation of contaminated sites in Korea

  • Hwang, Sang-Il;Park, Eung-Ryeol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.10a
    • /
    • pp.1-11
    • /
    • 2003
  • The objectives of this paper are to overview present status of soil pollution in Korea, to review the current policies and management strategies for soil pollution prevention and remediation of contaminated sites, and to suggest some recommendations to be considered toward more efficient policies. Soils in Korea are contaminated mainly by industrial facilities, landfills, underground storage tanks, abandoned/inactive mines, military camps, and other sources. Concentrations of most of soil pollutants were similar to the background levels, except for a few heavily contaminated sites such as industrial sites or abandoned/inactive mines. The Soil Environment Conservation Act (SECA), which was effective from 1995, provides a comprehensive legal framework for both preventing soil pollution and remedying contaminated sites in Korea. The Act includes various management policies such as the designation of standards and soil pollution policy area, soil monitoring networks, management of suspected contamination sources, and extended 'polluter-pays' principle. To make current policies more efficient and reasonable, some policies or strategies such as the establishment of national priority list, more detailed standards, risk-based cleanup goal, fund raise, soil erosion problem, and finally, integrity between soil and groundwater management frameworks may need to be pursued in the long term.

  • PDF

Current Status of Sanitary and Nutritional Food Service in Elderly Day Care Center (재가노인복지시설 급식소의 위생·영양관리 실태조사 연구)

  • Woo, Jeonghyeon;Park, Yoo Kyoung;Kim, Mi-Hyun;Lee, Soo-Kyung;Song, Kyunghee;Kim, Hye-Kyeong
    • Korean Journal of Community Nutrition
    • /
    • v.25 no.5
    • /
    • pp.374-385
    • /
    • 2020
  • Objectives: This study was conducted to examine the status of foodservice management, with special interest on sanitary and nutritional food service in elderly day care centers. Methods: A total of 79 employees who managed foodservice facilities in elderly day care centers were included in the survey. The contents of the questionnaire consisted of general characteristics, importance and performance of sanitary and nutrition management, the reasons for poor performance, factors necessary for improvement, and the employee's demand for support. Data analysis was conducted using the SPSS v25.0. Results: Sanitary management showed an average importance score of 4.84 ± 0.40 and a performance score of 4.70 ± 0.61 (t-value: 8.260). The item with the lowest performance score was personal sanitary management (4.58 ± 0.71). In nutrition management, the average importance score was 4.52 ± 0.68, and the performance score was 4.20 ± 1.00 (t-value: 9.609). There were significant differences between the average score of importance and performance in both areas. As a result of an Importance-Performance Analysis, items that were recognized as important but had relatively low performance was "personal hygiene", "ventilation" and "food storage". Also in the nutritional management area, "menu planning for disease management" and "checking the saltiness in the soup" etc. had very low performance with low importance recognition. The items shown in the "low priority" quadrant were those that required professional management skills. In the areas that demanded support in foodservice management, education about sanitary and safe institutional food service had the highest score (4.42 ± 0.74), and all other items showed a demand of 4 points or more. Conclusions: Foodservice managers recognize the importance of foodservice facility management but performance is relatively low. Institutional support is, therefore, needed to improve performance. For items with low importance, it seems necessary to improve awareness of the necessity of these items and to provide education in this regard. To gradually improve foodservice management, continuous provision of education and training in these areas are of great importance.

Impact Assessment of Forest Development on Net Primary Production using Satellite Image Spatial-temporal Fusion and CASA-Model (위성영상 시공간 융합과 CASA 모형을 활용한 산지 개발사업의 식생 순일차생산량에 대한 영향 평가)

  • Jin, Yi-Hua;Zhu, Jing-Rong;Sung, Sun-Yong;Lee, Dong-Ku
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.4
    • /
    • pp.29-42
    • /
    • 2017
  • As the "Guidelines for GHG Environmental Assessment" was revised, it pointed out that the developers should evaluate GHG sequestration and storage of the developing site. However, the current guidelines only taking into account the quantitative reduction lost within the development site, and did not consider the qualitative decrease in the carbon sequestration capacity of forest edge produced by developments. In order to assess the quantitative and qualitative effects of vegetation carbon uptake, the CASA-NPP model and satellite image spatial-temporal fusion were used to estimate the annual net primary production in 2005 and 2015. The development projects between 2006 and 2014 were examined for evaluate quantitative changes in development site and qualitative changes in surroundings by development types. The RMSE value of the satellite image fusion results is less than 0.1 and approaches 0, and the correlation coefficient is more than 0.6, which shows relatively high prediction accuracy. The NPP estimation results range from 0 to $1335.53g\;C/m^2$ year before development and from 0 to $1333.77g\;C/m^2$ year after development. As a result of analyzing NPP reduction amount within the development area by type of forest development, the difference is not significant by type of development but it shows the lowest change in the sports facilities development. It was also found that the vegetation was most affected by the edge vegetation of industrial development. This suggests that the industrial development causes additional development in the surrounding area and indirectly influences the carbon sequestration function of edge vegetaion due to the increase of the edge and influx of disturbed species. The NPP calculation method and results presented in this study can be applied to quantitative and qualitative impact assessment of before and after development, and it can be applied to policies related to greenhouse gas in environmental impact assessment.

Identifying Characteristics of Incidents at Hazardous Material Facilities

  • Kim, Geun-Young;Kim, Sang-Won;Won, Jai-Mu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.51-56
    • /
    • 2009
  • Safety and quality assessment systems are very important in manufacture, storage, transportation, and handling of hazardous materials(hazmat) to prevent hazmat disasters. At present, hazardous materials exist everywhere in our daily lives with various forms of plastics, household products of cleaning and washing detergents, fertilizers or petroleum-related products. However, hazardous materials are dangerous substances when they are released to human or environment. Hazardous materials become very widely used substances in the age of oil-based industrial economy. The Korean Ministry of Environment (KMOE) describes about one hundred thousand types of chemicals are produced and used worldwide. Over four hundred new chemicals are introduced in every year. A crucial question for the Korean hazardous material management may have been raised: Will you be safe from hazardous material incidents? The gas leak disaster at Union Carbide's Bhopal, India in 1984 that made over 6,400 people killed and 30,000 to 40,000 people seriously injured is the representative case for the safety of hazmat. Korea becomes vulnerable to hazmat disaster due to the development of high-tech industry. Thus, the risk assessment system is required to Korea for transferring abandoned hazmat management systems to self-correcting safety systems. This research analyzed characteristics of various hazmat incidents applying statistical analysis methods including frequency analysis or analysis of category data to hazmat incidents for ten years. All of three analyses of category data indicate the significance of causality between hazmat incident site groups and seasons, regional groups, and incident casualty groups.