• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.024 seconds

Effect of Carbon Sequestration and Oxygen Production of Trees on Kangwon National University Campus

  • Hyeong-Uk Ahn;Yun Eui Choi;Sung-Ho Kil;Hyun-Kil Jo
    • Journal of Forest and Environmental Science
    • /
    • v.39 no.3
    • /
    • pp.128-139
    • /
    • 2023
  • Urban forests serve multiple purposes by providing green resting spaces and environmental benefits for city residents. In the old city center, where parks are scarce, the campus of Kangwon National University, Chuncheon, Gangwon-do, South Korea, serves as an urban forest for students, faculty, and citizens. This study aims to quantitatively analyze the environmental functions of green spaces on campus, raising awareness about their importance among campus members. The total carbon storage of campus trees was estimated at 1,653,218 kg, including 1,512,586 kg in forest areas, 131,061 kg in planting spaces around buildings, and 9,571 kg in street spaces. The annual carbon uptake of campus trees was estimated to be 39,391 kg/year, with 30,144 kg/year in forest areas, 8,017 kg/year in planting spaces around buildings, and 1,230 kg/year in horizontal spaces. In addition, annual oxygen production was estimated to be 105,044 kg/year, with 80,385 kg/year in forest areas, 21,378 kg/year in planting spaces around buildings, and 3,281 kg/year in street spaces. Furthermore, we estimated carbon emissions from the use of on-campus facilities to be 4,856,182 kg/year, while oxygen consumption by members was estimated at 53,975 kg/year. However, the campus trees supplied a sufficient amount of oxygen, which was twice the amount required by school members. The carbon uptake amount was approximately 1% of the amount of carbon emissions, resulting in a modest contribution to improving the environmental conditions of the site.

Analysis of the Emergency Water Supply Capacity in Agricultural Reservoirs Using K-HAS and Ratio Correction Factors (K-HAS와 비율보정 계수를 이용한 농업용 저수지의 비상연계 용수공급 가능량 분석)

  • Kim, Hayoung;Lee, Sang-Hyun;Na, Ra;Joo, Donghyuk;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.59-71
    • /
    • 2023
  • As the frequency of drought increases due to climate change, water scarcity in agriculture would be a main issue. However, it seems difficult to solve the water scarcity by securing alternative water sources. The aim of this study is to analyze optimal water supply capacity of agricultural reservoir for emergency operation connecting reservoirs and dams. First, we simulated the water storage of agricultural reservoir playing the role emergency water supplier to other water facility such as dams and other reservoirs. In particular, the results of simulation of water storage through K-HAS model was calibrated using the optimization process based on ratio correction factors of outflow and inflow. Finally, the optimal amount of water supply securing water supply reliability in emergency interconnection operation was analyzed. The results of this study showed that Janchi reservoir could supply 12.8 thousand m3/day maintaining 90 % water supply reliability. The result of this study could suggest the standard for connecting water facilities as emergency water supply.

Personal Information Protection Recommendation System using Deep Learning in POI (POI 에서 딥러닝을 이용한 개인정보 보호 추천 시스템)

  • Peng, Sony;Park, Doo-Soon;Kim, Daeyoung;Yang, Yixuan;Lee, HyeJung;Siet, Sophort
    • Annual Conference of KIPS
    • /
    • 2022.11a
    • /
    • pp.377-379
    • /
    • 2022
  • POI refers to the point of Interest in Location-Based Social Networks (LBSNs). With the rapid development of mobile devices, GPS, and the Web (web2.0 and 3.0), LBSNs have attracted many users to share their information, physical location (real-time location), and interesting places. The tremendous demand of the user in LBSNs leads the recommendation systems (RSs) to become more widespread attention. Recommendation systems assist users in discovering interesting local attractions or facilities and help social network service (SNS) providers based on user locations. Therefore, it plays a vital role in LBSNs, namely POI recommendation system. In the machine learning model, most of the training data are stored in the centralized data storage, so information that belongs to the user will store in the centralized storage, and users may face privacy issues. Moreover, sharing the information may have safety concerns because of uploading or sharing their real-time location with others through social network media. According to the privacy concern issue, the paper proposes a recommendation model to prevent user privacy and eliminate traditional RS problems such as cold-start and data sparsity.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Geological analysis of the CarbonNet CCS project in the Gippsland Basin, Australia (호주 깁스랜드 분지 CarbonNet CCS 프로젝트의 지질학적 분석)

  • Hyun-Wook Jo;Ju-Won Oh;Young-Ju Lee;Ah-Reum Han;Jae-Young Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.4
    • /
    • pp.157-170
    • /
    • 2023
  • In South Korea, carbon capture and storage (CCS) techniques have attracted considerable attention as part of efforts to achieve the 2030 Korean Nationally Determined Contribution. However, owing to delays in large-scale CCS projects in South Korea, interest in cross-border CCS projects, wherein CO2 captured in South Korea is stored in overseas CCS facilities, has increased. In this study, we investigated the development status of the CarbonNet project in the Gippsland Basin, Australia. First, we provide a brief overview of sedimentary basins and CCS projects in Australia. Subsequently, we review the geological history of the Gippsland Basin, the site of the large-scale CCS project. Finally, we summarize the site selection process for the CarbonNet project and discuss the suitability of the Pelican site for large-scale CCS projects.

A Study on Safety Impact Assessment of a Multiple Hydrogen Refueling Station (다차종 동시 충전을 위한 수소 스테이션의 안전 영향 평가 연구)

  • Boo-Seung Kim;Kyu-Jin Han;Seung-Taek Hong;Youngbo Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.85-99
    • /
    • 2024
  • As the proliferation of hydrogen electric vehicles accelerates, there is observed diversification in hydrogen refueling station models. This diversification raises safety concerns for different types of stations. This study conducted a quantitative risk assessment of a multi-vehicle hydrogen station, capable of simultaneously refueling cars, buses, and trucks. Utilizing Gexcon's Effects&Riskcurves Software, scenarios of fire and explosion due to hydrogen leaks were assessed. The study calculated the impact distances from radiative heat and explosion overpressure, and measured risks to nearby buildings and populations. The largest impact distance was from fires and explosions at dispensers and high-pressure storage units. High-pressure storage contributes most significantly to personal and societal risk. The study suggests that conservative safety distances and proper protective measures for these facilities can minimize human and material damage in the event of a hydrogen leak.

A Study on Risk Assessment of Leaking Methanol Storage Tank on Methanol Fueled Ship Using ALOHA & Bow-tie Method (ALOHA & Bow-tie 기법을 이용한 메탄올 추진 선박에서의 메탄올 저장탱크 누출 시 위험도 평가)

  • Jeonghak Lee;Jaehoon Jee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.5
    • /
    • pp.479-489
    • /
    • 2024
  • In this study, the risks of the leakage of a methanol-fueled ship's storage tank at Ulsan Port are evaluated using ALOHA and Bow-tie methodologies. ALOHA is utilized to estimate the damage range by calculating both the worst and alternative scenarios. The results of the toxic area of the vapor cloud range (ERPG-2 standard) indicate that the alternative (629 m) and worst (817 m) scenarios include the pier facilities of the onshore tank terminal and residential areas. The flammable area of the vapor cloud range (LEL 10% standard) is observed only on the ship with the alternative (126 m) and worst (218 m) scenarios. The thermal radiation level of concern (5.0 kW/m2 standard) affects only the ship in both the alternative (56 m) and worst (56 m) scenarios. Additionally, preventive and mitigation measures are evaluated by a panel of experts using the Bow-tie method. The measures are classified into "hardware" and "human" categories, with "gas-freeing system," "ventilation system," and "fire-fighting system" receiving the highest ratings for safety effectiveness and risk severity. Based on the evaluation above, a risk-assessment diagram is developed.

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.

Knowledge and Attitude toward Restaurant-Related Sanitation of New Restaurateurs (일반음식점 신규영업주의 위생관리지식 및 위생행정에 대한 태도)

  • Kim, Seun-Taek;Park, Jae-Yong;Kam, Sin;Han, Chang-Hyun
    • Korean Journal of Health Education and Promotion
    • /
    • v.15 no.1
    • /
    • pp.79-95
    • /
    • 1998
  • The purpose of this study was to investigate the sanitation affairs of general restaurants. The questionnaire survey on the attitude and knowledge toward sanitation, the attitude for sanitary administration and the sanitary education was conducted against new 600 restaurateurs who were educated from June 20 to July 11, 1996, at the administration hall's division of Kyungsangbook-do in charge of food industry that offered regular sanitary education to new restaurateurs annually. And the visit survey on sanitary practice was also conducted over 93 restaurateurs who obtained the commercial license for food service business. The findings from the survey were as follows; In regard to food sanitation, some 87.1 to 88.3% got the right knowledge about the reason and precaution of food poisoning, food's frozen or cold-storage, and the disposal of products after expiration of validity term. But it was about 20.8% to 50.0% who knew right about major precaution, storage temperature in refrigerator, fermented milk product's storage temperature and validity term. There was therefore a necessity for education in food sanitation. 38.2% of the subjects placed an emphasis on sanitary storage of foodstuffs as the most important thing in sanitary management. 33.8% emphasized cooking sanitation. The environmental sanitation was counted as the most important thing by 19.2%, and personal sanitation of worker was counted by 8.8%. There was differences in what they thought the most important thing was, according to the respondent's educational level and cooker. 86.6% replied it necessary to improve the sanitary level. The respondents who were younger or had better educational level emphasized more the need for it. Concerning health examination, 90.2% replied it necessary. 81.4% answered the reason was because there was a potentiality Quests might be infected with contagious disease. 78.5% pointed the need for sanitary education, but respondents with higher educational level less emphasized its needs. As the reason for poor sanitation, restaurateur's poor awareness about it was most frequently pointed out, by 46.9%. Cooking sanitation was most frequently counted, by 38.5%, as the first thing to be improved. As the most critical point in sanitary education, 34.5% indicated food's sanitary Quality control 30.9% mentioned sanitary treatment of kitchen facilities and peripheral environment, and 27.1% emphasized the summary of the general food sanitation. 77.7% answered to correct immediately in case of violating the Food Hygiene Law, and 12.0% replied to correct in the same case if they would get the order from public official or administrative action would be taken. Respondents with higher educational level answered more to correct immediately. What they wanted the government office to do toward sanitary improvement was a fund aid an facilities and management which was pointed out by 38.9%, a periodical sanitary education by 26.3% and a on-the-spot guidance of sanitary officials by 22.3%. In view of the food service business's sanitary practice, the rate of wearing a sanitary clothes was 32.9% in city and 35.0% in county. The rate of hand-washing without soap or non-washing at cooking was 73.9%, 85%, respectively. The rate of personnel sanitation was 34.2% in city and 50.0% in county. These things indicated the sanitation was not well practiced. To improve the poor sanitary conditions of the food service businesses, it is recommended to offer institutional backing and financial aid from administrative office, and encourage restaurateurs to take pride in their job. and conduct the sanitary education effectively by sanitary education institution.

  • PDF

Characteristics of Ammonia in Alkaline Stabilization Facility of Sludge from Sewage Treatment Plant (하수처리오니 알칼리 안정화 처리시설에서의 암모니아 발생특성)

  • Kim, Yong-Jun;Chung, David;Jeong, Mi-Jeong;Yoo, Hye-Young;Yoon, Cheol-Woo;Shin, Sun-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.23-33
    • /
    • 2016
  • The characteristics of ammonia generated from alkaline stabilization facilities was investigated which are for organic sewage sludge from wastewater treatment plants. The highest concentration of ammonia was found in mixing and curing process in alkaline stabilization facility and ammonia mainly showed a range of 87.78 ppm($66.62mg/m^3$) to 1,933 ppm($1,467.01mg/m^3$) by detection tube. This is presumed to occur because nitrogen oxides are converted into ammonia as the sewage sludge is mixed with lime. In some facilities, hydrogen sulfide and methyl mercaptan were detected in relatively high concentrations, but odor materials except ammonia were not detected in most of the facilities. The concentration of ammonia caused by process was generally high in the order of "mixing > curing > output > storage > drying > input." It was found that odor compounds are removed by wet absorption using sulfuric acid and sodium hypochlorite in the 5 alkaline stabilization facilities currently in operation. Each facility was designed to meet the concentration of after-treatment emission in 1 ppm($0.76mg/m^3$), 50 ppm($37.95mg/m^3$) or 100 ppm($75.89mg/m^3$), but no facility satisfied the design standard for their emssion limit. In case of ammonia, some workplaces in alkaline stabilization facilities exceeded the exposure limits established by the Ministry of Labor. It appears that proper ventilation should be provided for the safety of workers in future. No odor compound including ammonia was found by detection tubes in the border of the facilities, but trace amounts of odor compounds are expected to exist, given the current operational status of facilities.