• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.028 seconds

A Study on Knowledge Based-AR System for Pipe Maintenance Support in Offshore Structure (해양구조물에서의 파이프정비 지원을 위한 지식기반형 증강현실 시스템에 관한 연구)

  • Kim, Chung-Hyun;Lee, Kyung-Ho;Lee, Jung-Min;Kim, Dea-Seok;Han, Eun-Jung
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.178-184
    • /
    • 2010
  • Today, there has been a decrease in international shipping because of the weakening in global economies. Therefore, shipowners are thinking more about Floating Production Storage and Offloading (FPSO), which can perform functions related to the transporting, storage, and tracking of crude oil from oil wells. Given the huge expense of these special ships, shipowners require workers who can solve problems quickly and secure sustainable production functions in this age of globalization. Furthermore, it is important to design, construct, and maintain facilities so that a ship remains in operation over a long term. This paper discusses a system that uses knowledge-based AR to help workers improve their understanding and deal with pipeline equipment problems safely. In addition, it displays a 3CAD model and status information for products to improve their recognition on the FPSO that they intend to inspect. At the same time, the system works quickly and offers solutions for dangerous circumstances or malfunctions. It thus helps to maintain the functionality of the FPSO throughout its life-cycle.

The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area - (제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 -)

  • Kang, Youn-Ku;Lim, Tae-Sub
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

Corrosion Evaluation for Advanced Fuel Cycle Facilities (선진 핵연료주기 시설(AFC)의 부식건전성 조사, 분석)

  • Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.213-217
    • /
    • 2012
  • The amount of spent fuel from nuclear power plants has been increasing. An effective management plan of the spent fuel becomes a critical issue, because the storage capacity of each plant will reach its storage limit in a few years. The volume of high toxic spent fuel can be reduced through a fuel processing. Advanced Fuel Cycle (AFC) system is considered to be one of the options to reduce the toxicity and volume of the spent fuel. It is necessary to set up a test facility to demonstrate the feasibility of the process at the engineering scale. The objective of the work is a development of the safety evaluation technology for the AFC system. The evaluation technology of the AFC structural integrity and processes were surveyed and reviewed. Key evaluation parameters for the main processes such as electrolytic reduction, electrorefining, and electrowinning were obtained. The survey results may be used for the establishment of the AFC regulatory licensing procedure. The establishment of the licensing criteria minimizes the trials and errors of the AFC facility design. Issues taken from the survey on the regulatory procedure and design safety features for the AFC facility provide a chance to resolve potential issues in advance.

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

The Development of the HACCP Plan in Korean Rice Cake Manufacturing Facilities (시판 떡류 생산에서 HACCP Plan 개발을 위한 연구)

  • Lee, Hyo-Soon;Jang, Myung-Sook
    • Korean journal of food and cookery science
    • /
    • v.24 no.5
    • /
    • pp.652-664
    • /
    • 2008
  • In this study, a Hazard Analysis Critical Control Point (HACCP) plan was developed for the sanitary mass production of commercial Korean rice cake products (Gaepidduk, Injulmi, and Julpyon). The microbiological properties of manufacturing flow were evaluated in order to develop the HACCP Plan. The moisture contents of the rice cakes ranged between 36.2${\sim}$55.3%, whereas the water activity of all samples ranged between 0.954${\sim}$1.0. Microorganisms testing was conducted during various phases of the product flow of Korean rice cake preparation, and included assessments of food equipment, work environment, and cooking employees on a small scale. During the manufacture of Injulmi, Julpyon and Gaepidduk, CCPs were purchasing & storage, steaming and cooling, molding, and holding in the A and B manufactories. At the critical limit of CCPs, storage was conducted below at $5^{\circ}C$ in soybean powder, oil, and paste with redbeans. The steaming process was conducted above at $99^{\circ}C$ for 40 min. Cooling and holding processes were conducted for 2 hours below at $15^{\circ}C$. The molding process included sanitary education for foodhandlers and training for operators. Thus, certain prerequisite programs had to be implemented prior to the implementation of the HACCP system. High levels of bacterial contamination were detected in the aprons worn to work by some employees. Additionally, periodic sanitary education for foodhandlers and training for operators or managers was required. Cross contamination by materials was expected at the place where materials were processed or stored.

Isotopic Fissile Assay of Spent Fuel in a Lead Slowing-Down Spectrometer System

  • Lee, Yongdeok;Jeon, Juyoung;Park, Changje
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.549-555
    • /
    • 2017
  • A lead slowing-down spectrometer (LSDS) system is under development to analyze isotopic fissile content that is applicable to spent fuel and recycled material. The source neutron mechanism for efficient and effective generation was also determined. The source neutron interacts with a lead medium and produces continuous neutron energy, and this energy generates dominant fission at each fissile, below the unresolved resonance region. From the relationship between the induced fissile fission and the fast fission neutron detection, a mathematical assay model for an isotopic fissile material was set up. The assay model can be expanded for all fissile materials. The correction factor for self-shielding was defined in the fuel assay area. The corrected fission signature provides well-defined fission properties with an increase in the fissile content. The assay procedure was also established. The assay energy range is very important to take into account the prominent fission structure of each fissile material. Fission detection occurred according to the change of the Pu239 weight percent (wt%), but the content of U235 and Pu241 was fixed at 1 wt%. The assay result was obtained with 2~3% uncertainty for Pu239, depending on the amount of Pu239 in the fuel. The results show that LSDS is a very powerful technique to assay the isotopic fissile content in spent fuel and recycled materials for the reuse of fissile materials. Additionally, a LSDS is applicable during the optimum design of spent fuel storage facilities and their management. The isotopic fissile content assay will increase the transparency and credibility of spent fuel storage.

A Study on Battery Charging and Supply System of Electric Vehicle Using Photovoltaic Generation (태양광 발전을 이용한 전기자동차 배터리 충전 및 공급시스템에 관한 연구)

  • Choi, Hoi-Kyun
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.265-273
    • /
    • 2017
  • Recently the Paris Climate Change Accord has been officially put into effect, making global efforts to implement Greenhouse Gas (GHG) reductions, and also International environmental regulations in the automotive sector will be further strengthened. The electric vehicle, which minimizes the particulate matter generated by existing internal combustion engine automobiles, is evaluated as a representative eco-friendly automobile. However, charging the battery of an electric vehicle is not fully environment-friendly if it is fueled by electricity that is being generated by fossil fuels as an energy source. The energy generated by the photovoltaic power generation system, which is an infinite clean energy, can be used to charge an electric vehicle's battery. Currently, shortage of charging facilities, time of charging, and high battery prices are the problem of activating the supply of electric vehicles. This study is to build a conjunction between the EVBSS (Electric Vehicle Battery Supply System) and ESS (Energy Storage System), which can quickly supply the photovoltaic charged battery to the required demand. If the charged battery in the Battery Swapping Station (BSS) is swapped swiftly, it will dramatically shorten the waiting time for charging the battery. As a result, if the battery is rented when it is needed, electric vehicles can be sold without the cost of a battery, which accounts for a large portion of the total cost, then the supply of electric vehicles are expected to expand. Furthermore, it will be an important alternative to maneuver climate change by minimizing GHG emissions from internal combustion engine vehicles.

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

Developed Stand alone PMS for ESS Safety Operation (ESS 안전 운영을 위한 독립형 PMS 개발)

  • Oh, Hong-Geun;Kim, Chul-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.351-360
    • /
    • 2019
  • Recently, the use of ESS facilities has been increased under the government's energy policy and at the same time, the various accident incidents such as fire and explosion occurred. Currently the ESS is installed as integrated ESS which includes PMS(: Power Management System), However, when the accident occurs, this system has high possibilities of losing the data due to oxidization, and the administrator cannot respond promptly. Therefore, in this paper, by constructing a separate WAS and data storage, it is possible to separate the main functions of the conventional system, to enable external EMS operation, and at the same time to quickly respond to the cause and cause of the accident occurrence. We will propose the development of a standalone PMS that is possible to respond.

Utilization of Subway Stations for Drone Logistics Delivery in the Post-Pandemic Era (포스트 팬데믹 시대 드론 물류배송을 위한 지하철 역사의 활용방안)

  • Moon, Sang-Won;Lee, Han-Byeol;Kang, Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.12
    • /
    • pp.375-383
    • /
    • 2021
  • Due to COVID-19, people are building new lifestyles such as online shopping, online travel, and video conferencing by limiting going out and gatherings. Such rapid social change is causing new problems and deepening existing problems at the same time. In particular, as online consumption increases significantly, traffic congestion, air pollution, and the heavy workload of delivery drivers are deepening in the daily logistics industry, and face-to-face delivery is emerging as a new problem. With the advent of the 4th industrial revolution, unmanned delivery using drones, artificial intelligence, and autonomous driving is emerging as an alternative to the existing logistics industry. However, space for logistics facilities and securing additional logistics sites due to drone flight are emerging as new problems to be solved. Therefore, it is intended to link additional services such as logistics movement, storage, and delivery by utilizing the existing transportation business, the subway, as a space for a logistics facility for drones that can solve existing problems and new problems.