• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.022 seconds

A study on bicycle storage improvement in Seoul -Focusing on the bicycle storage in Seoul subway transit links- (서울시 자전거 보관소의 개선방안 -서울시 지하철 연계 환승 보관소를 중심으로-)

  • Park, Yeun-Kyung;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.405-411
    • /
    • 2016
  • Seoul city is publishing new plans to increase modal share rate of bicycle every year, such as, maintaining bicycle related facilities. But bicycle's modal share rate in Seoul stayed same for the last decade and people are still facing difficulties using bicycle related facilities. These problems are causing bicycle usage as connecting transportation of public transit to decrease. This study looked at the high bicycle modal countries, such as, Netherlands, Germany and Japan to find applicable solutions by analyzing cases and comparing them with cases of highly populated subway station of Sindorim in Seoul. For example, in Germany and Netherlands there is bicycle-parking system to help bikers to access subway easier, in Japan there is underground bicycle parking tower to safely keep high volume of bicycles with in small space. For Seoul city to increase its modal share rate, they should look at problems from users' prospective and solve it by fixing it and improving the services, not by making more facilities.

A Study for the Establishment of Appropriate Facilities Criteria of the Korean Welfare Devices Center (한국형 복지용구사업소의 적정 시설기준 수립을 위한 기초 연구)

  • Chin, Young Ran;Bae, Joa Sup;Chung, Jae Wook;Lee, Hyo Young
    • 한국노년학
    • /
    • v.30 no.4
    • /
    • pp.1163-1177
    • /
    • 2010
  • This study was conducted to establish the appropriate facilities criteria of the Korean welfare devices center. We e-mail surveyed 194 welfare devices centers and analysed 13 blueprints of them. We established the following proper principles of facilities. First, consist type and area of room should depend on the type of welfare devices centers. Second, The flow of human and welfare devices should be simple. Third, the area calculated on the base of intent of center owner and the size of beds, wheelchairs, etc. Fourth, exhibit room facing with roadside may obtain advertising effect. Fifth, the storage and disinfecting room should use different entrance, and avoid the intersection of flow to prevent cross-contamination. Sixth, the access road to the exhibition and consulting room should be able to approach by the wheelchair. seventh, office room should be invisible to keep customer's privacy. Direct Cleaning-disinfecting type center on the premise that the maximum 165m2, middle 150m2, intermediate 140m2, display at least Consultation, Cleaning-disinfecting room, storage (clean, contaminated), the office, equipped with a parking space. Entrust Cleaning-disinfecting type center on the premise that a maximum 134m2, middle 119m2, intermediate 109m2 exhibited minimal activity room, consultation room, office, equipped with a parking space, collecting welfare when importing equipment warehouse (clean, pollution) have been proposed to equip up to.

A Design of N-Screen based Monitoring System for Marine-Facility (N-Screen 기반의 해양시설물용 모니터링 시스템 설계)

  • Kim, Ji-Yoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.613-622
    • /
    • 2015
  • The convergence of IT technology and marine facilities monitoring system is needed for effective monitoring systems to marine facilities. Especially the spread of smart device such as smart phone, smart pad, smart TV provide an environment that can check the status of the marine facility for marin facilities manager. However, smart phones and smart pads are used in a variety of OS used. Thus the monitoring system of the various service environments is difficult. In addition, There is inconvenience that must individually developed monitoring system for each device. In order to solve this problem NMMS (N-Screen Marine-facility Monitoring System) is proposed. NMMS is consist of Real-time monitoring system, Fault diagnosis system, Data storage system. To improve variety of smart devices accessibility, we use HTML 5. Through NMMS, marine facilities manager can use smart device such as PC, Notebook, smart phone, smart pad for marine facilities monitoring.

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

Application of ATP bioluminescence assay for effect assessment of hygiene visiting education on children's foodservice facilities in the local small town (ATP bioluminescence assay를 이용한 경북 일부 어린이 급식시설에 대한 위생방문교육의 효과 평가)

  • Pak, Hye-Jin;Cheigh, Chan-Ick
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.501-508
    • /
    • 2021
  • The purpose of this study was to evaluate the application of ATP bioluminescence assay for effect assessment of hygiene visiting education on children's foodservice facilities in the local small town. The sanitary inspection results of the hygiene visiting education showed significant improvement in all items except 'To regularly disinfect cooking facilities, storage rooms, etc.' ATP bioluminescence analysis was performed on cooking utensils to evaluate the educational effect, and the results showed a correlation with the effect in most items. In the case of knives and cutting boards, all facilities showed a value of 20 RLU/cm2 or less after the educational support, and in particular, it was approximately 10 RLU/cm2 or less in national/public, corporation and private facilities. Correlation analysis between the post-education sanitary inspection results and ATP values for three items related to knives and cutting boards showed that they have a negative and high correlations.

Determination of Optimum Capacity Rainwater Utilizing Facilities by Analysis of the Water Supply by Land Use Scenario (토지이용 시나리오별 용수공급 분석에 따른 빗물이용시설 최적 용량 결정)

  • Lim, Seok Hwa;Kim, Byung Sung;Ryoo, Kyong Sik;Lee, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Most of Korea's agricultural water is supplied by reservoirs, so dependence on them is very high. Accordingly, it is important to reduce this dependence and provide a stable agricultural water supply by utilizing an applicable alternative water source. Therefore, in this work, scenarios for different land uses were constructed, and an optimal water supply plan using rainwater and reused sewage water - which are alternative water sources - was created. A study was also conducted to determine the optimal capacity of a rainwater facility. From the analysis, a stable water supply was achieved in the scenario of maximum utilization of rainwater by changing an existing paddy area to a greenhouse area, and about 0.82 ton of flow capacity was required for 1 mm of rainfall on farms utilizing rainwater. As a result of analyzing the optimal scenario to derive the ratio of the storage capacity per unit water collection area, the rainwater storage capacity determined through MODSIM and the storage capacity determined through actual monitoring showed similar results, about 31 and 32 %, respectively, and the optimal capacity of rainwater facilities was calculated to be about 5,796,000-6,182,400 ton.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

A Study on the Flooding Risk Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 침수 위험성 평가에 관한 연구)

  • Ryu, Seong-Reul
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • Purpose: For smooth performance of flood analysis due to heavy rain disasters at energy storage facilities in the Incheon area, field surveys, observational surveys, and pre-established reports and drawings were analyzed. Through the field survey, the characteristics of pipelines and rivers that have not been identified so far were investigated, and based on this, the input data of the SWMM model selected for inundation analysis was constructed. Method: In order to determine the critical duration through the probability flood analysis according to the calculation of the probability rainfall intensity by recurrence period and duration, it is necessary to calculate the probability rainfall intensity for an arbitrary duration by frequency, so the research results of the Ministry of Land, Transport and Maritime Affairs were utilized. Result: Based on this, the probability of rainfall by frequency and duration was extracted, the critical duration was determined through flood analysis, and the rainfall amount suggested in the disaster prevention performance target was applied to enable site safety review. Conclusion: The critical duration of the base was found to be a relatively short duration of 30 minutes due to the very gentle slope of the watershed. In general, if the critical duration is less than 30 minutes, even if flooding occurs, the scale of inundation is not large.

Research on Optimized Operating Systems for Implementing High-Efficiency Small Wind Power Plants (고효율 소형 풍력 발전소 구현을 위한 최적화 운영 체계 연구)

  • Young-Bu Kim;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.25 no.2
    • /
    • pp.94-99
    • /
    • 2024
  • Recently, wind power has been gaining attention as a highly efficient renewable energy source, leading to various technological developments worldwide. Typically, wind power is operated in the form of large wind farms with many wind turbines installed in areas rich in wind resources. However, in developing countries or regions isolated from the power grid, off-grid small wind power systems are emerging as an efficient solution. To efficiently operate and expand off-grid small-scale power systems, the development of real-time monitoring systems is required. For the efficient operation of small wind power systems, it is essential to develop real-time monitoring systems that can actively respond to excessive wind speeds and various environmental factors, as well as ensure the stable supply of produced power to small areas or facilities through an Energy Storage System (ESS). The implemented system monitors turbine RPM, power generation, brake operation, and more to create an optimal operating environment. The developed small wind power system can be utilized in remote road lighting, marine leisure facilities, mobile communication base stations, and other applications, contributing to the development of the RE100 industry ecosystem.

Analysis on Hydraulic Characteristics in Down Stream of Dam for Fishway Construction (어도설치를 위한 댐하류 수리특성 분석)

  • Maeng, Seung-Jin;Lee, Bae-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.11-20
    • /
    • 2007
  • In this study, we reviewed the optimal space for the fishway and fish storage establishment in the section between the downstream of the Hwacheon dam and the confluence of the Pungsan river. The hydraulic stability of these facilities was also examined. In the section between the downstream of Hwacheon dam and the confluence of Pungsan river, the release flow of Hwacheon dam was set at $5,495m^3/s,\;6,110m^3/s$ and $7,537m^3/s$, and numerical simulations were executed for each instance using the HEC-RAS model and RMA-2. In the analysis of the flow velocity distributions in the subject section by release flows of Hwacheon dam, it was shown that there was over 5.0m/s of high flow velocity at Sta. $#1{\sim}Sta.$ #3, Sta. $#4{\sim}Sta.$ #6, and Sta. $#12{\sim}Sta.$ #13 of the sections analyzed in this study. The Sta. $#0{\sim}Sta.$ #1 was considered appropriate for the fishway and fish storage establishment. As seen in the results of the numerical stability review by release flow conditions of Hwacheon dam subject to the selected available areas fur fishway and fish storage, the topographically available section for the establishment of fishway and fish storage exists at Sta. $#1{\sim}Sta.$ #3 when the release flow of Hwacheon dam is $5,495m^3/s$, whereas Sta. $#0{\sim}Sta.$ #1 should be reviewed for the subject section for the establishment of fishway at release flows of $6,110m^3/s$ and $7,537m^3/s$, in addition to the figures gathered at the $5,495m^3/s$ release flow. Finally, the available section for the establishment of fishway and fish storage was determined to be Sta. $#0{\sim}Sta.$ #3. Further, if fishway and fish storage are established in the outer bank within this section, the high flow velocity section should be avoided. An alternative would be to establish for the fishway in the inner band on the section of Sta. #1 or Sta. #3.