• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.024 seconds

Optimal Design of Batch-Storage Network with Finite Intermediate Storage (저장조 용량제약이 있는 회분식 공정-저장조 그물망 구조의 최적설계)

  • Kim, Hyung-Min;Kim, Kyoo-Nyun;Lee, Gyeong-Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.867-873
    • /
    • 2001
  • The purpose of this study is to find analytic solution of determining the optimal capacity (lot-size) of multiproduct acyclic multistage production and inventory system to meet the finished product demand under the constraint of finite intermediate storage. Intermediate storage is a practical way to mitigate the material flow imbalance through the line of supply and demand chain. However, the cost of constructing and operating storage facilities is becoming substantial because of increasing land value, environmental and safety concern. Therefore, reasonable decision-making about the capacity of processes and storage units is an important subject for industries. The industrial solution for this subject is to use the classical economic lot sizing method, EOQ/EPQ(Economic Order Quantity/Economic Production Quantity) model, incorporated with practical experience. But EOQ/EPQ model is not suitable for the chemical plant design with highly interlinked processes and storage units because it is developed based on single product and single stage. This study overcomes the limitation of the classical lot sizing method. The superstructure of the plant consists of the network of serially and/or parallelly interlinked non-continuous processes and storage units. The processes transform a set of feedstock materials into another set of products with constant conversion factors. A novel production and inventory analysis method, PSW(Periodic Square Wave) model, is applied to describe the detail material flows among equipments. The objective function of this study is minimizing the total cost composed of setup and inventory holding cost. The advantage of PSW model comes from the fact that the model provides a set of simple analytic solutions in spite of realistic description of the material flows between processes and storage units. the resulting simple analytic solution can greatly enhance the proper and quick investment decision for the preliminary plant design problem confronted with economic situation.

  • PDF

A study on the work in fishing convention, 2007 and the fishing vessel's accommodation facilities standards in national fishing vessel act (ILO어선원노동협약과 어선법의 어선거주설비에 대한 고찰)

  • Kim, Wook-Sung;Park, Moon-Gap
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.466-475
    • /
    • 2010
  • This study intends to present a direction for the better reforming of fishers'onboard living conditions and proposals for preparing for ratification of the Work in Fishing Convention by means of making a comparison between standards on recent national fishing vessel accommodation facilities and standards on the Work in Fishing Convention and Its Recommendation, 2007, ILO. For the most part of standards on national fishing vessel accommodation facilities are somewhat insufficient to satisfy the provisions in Annex III of the Convention. Considering by items on fishing vessel accommodation facilities, the standards on insect protector, noise and vibration, heating and air conditioning, lighting, persons per sleeping room, recreational facility are not provided in national law. Headroom, separation of accommodation, sleeping room floor area, mattress size, mess room, galley and food storage are partially sufficient for the Convention. In case of sanitary facilities, national standards are not sufficient for the Convention. The other side, facilities related safety of ship and crew such as emergency escape etc., are fully sufficient for the Convention. These insufficiencies caused by different types of fishing vessel depend on originality of fishing method and practices. In the comparison between equivalent tonnage about vessel's length on convention and calculated tonnage of national existing fishing vessel, the difference are 226tons about length 24m and 501tons about length 45m. For that reason, headroom, persons per sleeping room, cabin of sicker and injured, sanitary facilities may decide to use gross tonnage in place of length (L) and the alleviating measure basis of convention. But in case of standards on sanitary facilities which are unsufficient for the Convention, specially in coastal fishing vessel length basis should be adopted with alleviating basis for less than length 24m.

A Study on the vulnerability of the agricultural infrastructure based on the product of garlic and onions - Focused on Jeolla-do and Gyeongsang-do - (마늘 및 양파 주산지 농업생산기반시설의 취약성 분석 - 전라도, 경상도를 중심으로 -)

  • Jung, hyunwoo;Paik, sinwon;Kim, hanjoong
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.143-152
    • /
    • 2017
  • In recent years, the proportion of arable land in the nation has grown from 36.2 percent in 1990 to 43.7 percent in 2013. The study first performed the vulnerability assessment of agricultural production, transportation, processing facilities, agricultural machinery leasing facilities, and water supply facilities. It was developed for the evaluation of the vulnerability of each gun of garlic and onions based on the distance from the three groups of arable bodies to the facility and the processing capacity of facilities. In view of these regional imbalances, the store, distribution and processing facilities in the main stream were found in Haenam, South Jeolla-do, and the relatively low regions of the gun were located in Goheung-gun and Hampyeong-gun. Among other regions, agricultural machinery rental facilities were high in Changnyeong-gun, Haenam, and two regions, while the water supply facilities were high in the southern area of Haenam and South Jeolla-do. The Gyeongsang-do showed relatively high levels of comparison vulnerability index compared to Jeolla-do regions. In particular, through the management plan to improve the facilities needed to improve agricultural production infrastructure, it is necessary to increase the competitiveness of agricultural productuivity through the planning of the need for additional support through the rural readjustment project.

Hydrological Evaluation of Rainwater Harvesting: 1. Hydrological Analysis (빗물이용의 수문학적 평가: 1. 수문해석)

  • Yoo, Chulsang;Kim, Kyoungjun;Yun, Zuhwan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.221-229
    • /
    • 2008
  • This study revised a model for hydrologically analyzing rainwater harvesting facilities considering their rainfall-runoff properties and the data available. This model has only a few parameters, which can be estimated with rather poor measurements available. The model has a non-linear module for rainfall loss, and the remaining rainfall excess (effective rainfall) is assumed to be inflow to the storage tank. This model has been applied for the rainwater harvesting facilities in Seoul National University, Korea Institute of Construction Technology, and the Daejon World Cup Stadium. As a result, the runoff coefficients estimated were about 0.9 for the building roof as a rainwater collecting surface and about 0.18 for the playground. This result is coincident with that for designing the rainwater harvesting facilities to show the accuracy of model and the simulation results.

Method for network divided subscriber's facilities (망 분리 가입자 부가 서비스 제공 방법)

  • Yoon, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • In this paper, to provide a method for providing a network separation subscriber's facilities. How to provide this subscriber's facilities include phase generating authorization key in server, saving activation file in portable data medium included server's authorization key, executing saved activation file in client's portable storage and providing virtual machine by result client's execute file. In case of moving work, the virtual subscriver's facility can provide for a business traveler.

Solar Absorption Cooling System applicable to Educational Facilities (교육시설에 적용 가능한 태양열 흡수식 냉각 시스템)

  • Youn, Sung-Min;Paek, In-Su;Han, Young-Tae;Nam, Hyo-Gab
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.3
    • /
    • pp.35-41
    • /
    • 2011
  • Performance of a small-capacity solar absorption cooling system was investigated experimentally. Ten sets of evacuative-tube solar-heat collectors and a 5 kW single-stage absorption cooler were combined to produce a hybrid cooling system. The performance of the cooling system was measured using a tim-coil unit installed in a small plastic storage. It was found from the test on a sunny day of May that when the temperature of the hot water supplied from the solar collectors to the generator of the absorption cooler reached $60^{\circ}C$, the absorption cooler started cooling and the cold water temperature measured from the fan-coil unit reached $18^{\circ}C$. The COP, which is defined as the ratio of the cooling power to the total electrical power input was higher than 1.0.

  • PDF

INCIDENT FREQUENCY AND SEVERITY FOR CONSTRUCTION FACILITIES

  • Jong-Hyun Park;Jae-Su Jeong;Chan-Sik Lee
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.234-240
    • /
    • 2011
  • Preventing incidents occurred in construction process is important for safe implementation of construction projects. Due to the complexity and magnitude of the project and moreover, poor safe planning and management, construction incidents in Korea have been increasing. Reducing construction incidents effectively, appropriate safety management program in consideration of the incident rate of each facility is to be adapted. This study analyzes incident frequency and severity rate of each facility based on the data of construction sites(about 1,560 thousand cases) recorded by Korea Occupational Safety & Health Agency for 3 years from 2007 to 2009, and the incident related data (about 40 thousand cases) of Korea Workers' Compensation & Welfare Service. The results of this study revealed that construction incident rates of 'cold refrigeration storage facilities' are the highest among building types, followed by traditional building religious building, arcade department store and shopping center. In case of other facilities, the incident rate and the rate of intensity of 'pipelining project' are the highest, followed by 'tunneling project'. These results would be used in providing safety programs beneficial for preventing construction incidents.

  • PDF

Space Efficiency Improvement for Open Access Library -Focused on Book-storage Space of Academic Libraries in Province Area- (개가식 도서관의 공간효율 제고 방안 -지역 대학도서관 서고 공간을 중심으로-)

  • Ahn, Joon Suk
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • Due to an inability to accommodate for the rapidly increasing number of printed materials, Korean academic libraries are facing serious space shortage problems. Very few academic institutions have the funds to expand existing libraries or construct new facilities in order to accommodate the influx of printed materials. Despite not having the luxury to create new space, many establishments continue to implement the open access system. Seeing that such a system is only user friendly when used in a spacious facility, the maintenance of the open access system is unreasonable. Only few libraries consider the space efficient closed access system which helps to resolve storage space shortage. In the current state of the problem, improving the efficiency to which books are stored in existing storage areas within a library facility is the only appropriate solution. Enacting methods to improve physical space utilization within a fixed volume library facility will undoubtedly diminish the space shortage issue at hand. In this article, several space efficiency improvement approaches are discussed. Methods of book storage plan re-layout (floor, plan, ceiling, height, bookshelf design), book arrangement possibilities, and the reduction of the physical volume of reserved materials are each examined.

The Analysis of Rainwater Storage Facility Project for the Urban Disaster Prevention in Busan and its Countermeasures (도시방재를 위한 부산지역 우수저류시설 설치사업의 분석과 대책)

  • Hwang, Jae-Yun
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2015
  • Recently, many cities have always been affected by large natural disasters such as floods and landslides. As climate change causes more frequent localized heavy rains exceeding the conveyance capacity of sewer, flood damage is expected to increase. For the sake of reducing the urban flood damage by changed rainfall, there has been many trials on installation of runoff-reducing facilities. Therefore, it was required to study about reasonable analysis and countermeasure of rainwater storage facility project for extending it. This study was to review the status of rainwater storage facility project for the urban disaster prevention in Busan, to find out problems, and to propose the countermeasure of rainwater storage facility project for the urban disaster prevention.

Analysis of Efficiency of Solar Hot Water System based on Energy Demand (에너지 수요처의 사용특성에 따른 태양열 급탕시스템의 효율분석)

  • Jun, Yong-Joon;Park, Kyung-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.5
    • /
    • pp.39-47
    • /
    • 2017
  • In a hot water system using solar energy, solar heat is not simply collected by the heat collecting plate, but by heat exchange between the solar collector (flat or vacuum type) and the hot water storage tank. Therefore, the amount of collected solar energy depends on the hot water usage patterns that determine the temperature of the thermal storage tank. Also, if the temperature of the hot water stored in the storage tank exceeds the dangerous temperature during the summer, the heat must be released for safety. If the temperature of the hot water in the storage tank is low, it is necessary to heat by the auxiliary heat source. In this study, three buildings are defined as hotel, swimming pool, and school facilities. And we calculated the released heat energy, auxiliary heat source, and pure storage heat energy based on different hot water usage patterns and installation angle of the solar collectors.