수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착 (Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring)

  • 강채동;손권;백종현;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

가스냉방 보급효과에 대한 연구 (Study on The Supplying effect of Gas Air Conditioning Systems)

  • 한정옥;채정민;최경식;홍성호
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.19-25
    • /
    • 2011
  • 냉방용 에너지는 크게 전력과 가스로 대별할 수 있는데, 전기냉방 시스템은 하절기 최대전력을 상승시키는 요인이 되고 있다. 전기에너지는 수요 공급 특성상 저장이 불가능하기 때문에 예상되는 최대전력을 상회하는 공급능력을 보유해야 하며 매년 하절기의 사회문제로 대두되어 왔다. 한편 가스냉방의 경우 흡수식 시스템과 GHP 시스템이 있다. 그러나 가스냉방 보급용량은 전기 냉방에 비해 매우 적으며 소형시장은 대부분 전기냉방에 의존하고 있는 상황이다. 본 논문에서는 국내 냉방에너지 현황을 살펴보고 에너지원간의 부하분담 비중을 분석하여 냉방에너지의 합리적인 방향을 제시하고자 2024년까지 장기적인 가스냉방 보급 규모를 전망하였으며, 이를 바탕으로 가스냉방 보급효과를 분석하여 가스냉방의 확대 필요성을 뒷받침 하고자 하였다.

동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구 (The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

상온 상압의 이산화탄소 저장용 탱크를 위한 예냉과정의 비선형 모델링 및 비례-적분 제어 적용 (Nonlinear Modeling and Application of PI Control on Pre-cooling Session of a Carbon Dioxide Storage Tank at Normal Temperature and Pressure)

  • 임유경;이석구;단승규;고민수;이종민
    • Korean Chemical Engineering Research
    • /
    • 제52권5호
    • /
    • pp.574-580
    • /
    • 2014
  • 이산화탄소($CO_2$) 포집 및 지중저장을 위한 $CO_2$ 수송선용 저장탱크는 액체 $CO_2$와 직접적으로 접촉할 경우 발생할 수 있는 물리적/열적 탱크 손상을 방지하기 위해 화물 선적 단계 이전에 예냉과정을 거쳐야 한다. 본 연구에서는 예냉을 위해 주입되는 저온 $CO_2$ 기체의 탱크 유입량을 계산하기 위해 $CO_2$ 저장탱크 예냉과정의 수학적 모델 식을 제안하였다. 또한 비례-적분(proportional-integral: PI) 제어를 통해 공정을 제어하는 동적 모사 결과를 제시하였다. 이 때 제어 변수를 탱크 내 온도 또는 압력으로 선정한 두 가지 사례를 모사하였으며 그러한 결정이 $CO_2$ 저장탱크의 예냉과정에 미치는 영향을 해석하였다. 결과적으로 예냉과정의 PI제어에는 탱크 내 온도를 제어하는 것보다 압력을 제어하는 우회적인 방식을 택할 때 수학적 모델의 비선형성과 특이점 발생으로 인한 불안정성을 피할 수 있으므로 더 안정된 결과가 도출됨을 보였다.

열병합발전소에서의 축열조 증설에 의한 온실가스 감축 효과 분석 (Greenhouse Gas Mitigation Effect Analysis by Establishing Additional Heat Storage System for Combined Heat and Power Plant)

  • 김상목;윤중환;임경미
    • 한국기후변화학회지
    • /
    • 제2권3호
    • /
    • pp.175-189
    • /
    • 2011
  • 본 연구에서는 분당복합화력발전소의 축열조 증설과 이에 따른 운영 방식 최적화를 통해 예상되는 온실가스 감축 효과에 대한 방법론과 정량화를 기술하였다. 분당복합화력은 일산, 안양, 부천복합화력과 함께 복합화력과 열공급 전용 지역난방발전소의 중간 형태이다. 이는 자체 운전 모드 변경을 통해 복합화력 기능인 전력만을 공급하는 것과 지역난방 기능의 전력 및 열을 동시 공급하는 운전 형태 변환이 가능하다는 의미이다. 따라서 축열조를 증설함으로써 고효율 모드인 전력 및 열을 동시 생산하는 열병합 발전과 전력 피크 부하를 위한 복합발전으로의 운전전환을 통해 전력 및 열공급시장의 요구량에 유연성 있게 대처할 수는 공급능력을 가지게 된다. 본 연구는 분당복합화력의 최근 3년(2008~2010년) 운전실적과 각 운전모드별 운전효율은 설계치를 사용하여 계산하였으며, 그 결과 증설된 축열조에 공급되는 축열량 1 Gcal당 GHG 감축 효과는 $97.95kg_{-}CO_2/Gcal$로 연간 약 $13,500Ton_{-}CO_2$의 감축 효과를 기대할 수 있다.

축열 성능 향상 SSPCM 혼합 콘크리트 제조 및 열적특성 분석 (Preparation and Thermal-property Analysis of Heat Storage Concrete with SSPCM for Energy Saving in Buildings)

  • 정수광;장성진;임재한;김희선;류성룡;김수민
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.89-96
    • /
    • 2015
  • n-octadecnae based shape stabilized phase change material (SSPCM) was prepared by using vacuum impregnation method. And an exfoliated graphite nanoplate (xGnP) which has high thermal conductivity properties is used as a PCM container. And then we made heat storage concretes which contains SSPCM for reducing heating and cooling load in buildings. In the prepararion process, the SSPCM was mixed to a concrete as 10, 20 and 30wt% of cement weight. The thermal properties and chemical properties of heat storage concrete were analyzed from Scanning electron microscope (SEM), Fourier transformation infrared spectrophotometer (FT-IR), Deferential scanning calorimeter (DSC), Thermogravimetric analysis (TGA) and TCi thermal conductivity analyzer. And we conducted surface temperature analysis of SSPCM and xGnP by using heat plate and insulation mold.

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례 (A Field Application Case of Direct Ice Slurry Transporting System for District Cooling)

  • 유호선;이상훈;이윤표
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.