• Title/Summary/Keyword: Storage coefficient

Search Result 470, Processing Time 0.025 seconds

Parameter Decision of Muskingum Channel Routing Method Based on the Linear System Assumption (선형시스템가정에 근거한 Muskingum 하도추적방법의 매개변수 결정)

  • Yoo, Chulsang;Sin, Jiye;Jun, Chang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.449-463
    • /
    • 2013
  • This study proposes the method for determining the Muskingum channel routing model parameters based on the assumption of linear system. The proposed method was applied to the Chungju dam basin for the evaluation. Additionally, the rainfall-runoff was repeated for the Yeongchun-Chungju dam reach using seven rainfall events observed. Summarizing the results is as follows. First, the concentration time and storage coefficient of a channel reach formed by the subdivision can be expressed as the difference between the concentration times and storage coefficients of upstream and downstream basins. The storage coefficients of the channel reach estimated is equal to the storage coefficient of the Muskingum channel routing model and the weight factor can be simply estimated using the ratio between the concentration time and storage coefficient. Second, the weight factor of the Muskingum model is in inverse proportion to the Russel coefficient, which is in between 0.4166 and 0.625 when considering the Russel coefficients generally applied. Finally the application to the Yeongchun-Chungju dam reach showed that the proposed method is still valid regardless of the limitations such as the uncertainty of the observed data.

Drying and Low Temperature Storage System of Agricultural Products using the Air to Air Heat Pump (II) - Performance of Low Temperature Storage for Apples - (히트펌프를 이용한 농산물 건조 및 저온저장 시스템 (II) - 사과의 저온저장 성능 -)

  • Kang, Y.K.;Han, C.S.;Keum, D.H.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.102-108
    • /
    • 2007
  • Heat pump systems are recognized to be heating and cooing systems. In this study, to check the practical application possibility of heat pump systems as low temperature storage systems and get basic data, apples of a long term storage items were stored and performance of low temperature storage and quality changes of apples were evaluated. Cooling coefficient of performance of the system was from 1.1 to 1.3. Although ambient air temperature varied widely from $-13^{\circ}C$ to $29.6^{\circ}C$ during low temperature storage period from January to June, the average temperature of low temperature storage chamber was $1.1^{\circ}C$ at setting temperature of $1.5^{\circ}C$. Sucrose of apples stored by the heat pump decreased from initial sucrose of 15.4% (Brix number) to final sucrose of 14.3%. Weight loss ratio of apples was 9.7% and internal and external view of apples after low temperature storage were very satisfactory with the naked eye.

Changes in Quality Characteristics of Brown Rice During Storage (저장중 현미의 품질 특성 변화)

  • 신명곤;민봉기;김동철
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.3
    • /
    • pp.276-280
    • /
    • 1991
  • The quality changes of brown rice during storage were determined by the method of quantitative analysis of n-hexanal, amylogram, texture and volume expansion. The qualities of stored brown rice were also analyzed with sensory evaluation of cooked milled rice obtained from brown rice, n-Hexanal content, peak viscosity and total setback of brown rice flour pastes increased substantially with the increased of storage period at 35$^{\circ}C$. Up to 10 months of storage at 35$^{\circ}C$, stale flavor obtained by a sensory method markedly increased, but stickiness decreased. The scores of overall preference were in good agreement with those of stale flavor (r=-0.98) and sticky texture (r=0.98). The correlation coefficient between stale flavor obtained by a sensory method and instrumetal analysis for stored brown rice was r=0.97.

  • PDF

The Study on Improvement in Subcooling of TMA Clathrate for PCM in Ice Storage System (빙축열시스템 PCM용 TMA-포접화합물의 과냉도 개선에 대한 연구)

  • Kim, J.H.;Chung, N.K.;Kim, C.O.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1663-1666
    • /
    • 2003
  • TMA clathrate that is used by PCM of ice storage system in this research creates hydrate crystallization at higher temperature than pure water, and application is expected as PCM because having comparative big dormant temperature without phase separation phenomenon. In case this research uses TMA clathrate by PCM, choose admixture by purpose to control or remove subcooling of TMA clathrate and evaluated experimentally. Subcooling is improved and can expect contraction of freezing machine running time and increase of coefficient of performance as that add admixture to TMA clathrate conclusively. Also, may supply thermal storage system that apply low temperature potential heat thermal storage material that subcooling is improved more extensively laying stress on medium size building and small size building, can expect allowance through localization of ice storage system.

  • PDF

Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank (태양열이용 Baffle형 축열탱크를 갖는 온수난방시스템의 열성능 해석)

  • Suh, Jeong-Se;Yi, Chung-Seub
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.768-773
    • /
    • 2009
  • A numerical study has been performed to investigate the thermal Performance of Solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

  • PDF

A study on the Operating Characteristics of the Capsule-type Ice Storage System (캡슐형 빙축열 시스템의 운전특성에 관한 연구)

  • Kim, Kyung-Hwan;Cho, Sung-Woo;Choi, Jeong-Min;Ha, Suk-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.199-204
    • /
    • 2005
  • The decrease of summer peak electric load of our country is very important. The government is arranging a lot of support policies and statutes. etc. to decrease of peak electric load. And ice storage system is known as one of the alternatives. The purpose of this study is to collect basic data for operating characteristics to plan the most suitable operation of capsule-type ice storage system. The storaging tank is designed to take charge 40% of total cooling load in building, In operation condition the storage tank took charge 50%. Coefficient Of Performance of daily screw refrigerator is around 4.

  • PDF

Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank (태양열이용 Baffle식 축열조를 갖는 급탕난방시스템의 열성능 해석)

  • Suh, Jeong-Se;Yi, Chung-Seub;Yoon, Ji-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.805-811
    • /
    • 2010
  • A numerical study has been performed to investigate the thermal performance of solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

Design method of heat storage type ground source heat pump system considering energy load pattern of greenhouse (원예시설의 에너지 부하패턴을 고려한 축열식 지열시스템 설계법에 관한 연구)

  • Yu, Min-Gyung;Nam, Yujin;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2015
  • Purpose: Ground source heat pump system has been attracted in the horticulture industry for the reduction of energy costs and the increasing of farm income. Even though it has higher initial costs, if it uses in combination with heat storage, it is able to reduce the initial costs and operate efficiently. In order to have significant effect of heat storage type ground source heat pump system, it is required to design the capacity considering various conditions such as energy load pattern and operating schedule. Method: In this study, we have designed heat storage type ground source heat pump system in 5 cases by the operating schedule, and examined the system to find the most economic and having superb performance regarding the system COP(Coefficient of Performance) and energy consumption, using dynamic energy simulation, TRNSYS 17. Result: Conventional ground source heat pump system has lower energy consumption than heat storage type, but following the result of LCC(Life Cycle Cost) analysis, the heat storage type was more economic due to the initial costs. In addition, it has the most efficient performance and energy costs in the case of the smallest heat storage time.

Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 운전특성 실험)

  • Choe, In-Su;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank (3중관 튜브형 잠열 축열조에서의 열전달 특성 연구)

  • Lee, W.K.;Han, G.Y.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF