• Title/Summary/Keyword: Storage coefficient

Search Result 470, Processing Time 0.025 seconds

Determination of Aquifer Parameters by the Improved Slope-Matching Method (개선된 SM(Slope-Matching) 방법에 의한 대수층의 특성변수 결정)

  • 김민환;오종민;전일권
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.73-81
    • /
    • 2001
  • With the development of industry and standard of living, the quantity of groundwater consumption has been increasing. For the analysis of groundwater, to determine the hydraulic parameters of aquifer is very important. Various numerical methods have been developed to solve aquifer tests and eliminate the subjectivity of traditional graphical type curve methods. The slope-matching method, which matches the slope of the Theis type curve to the slope of the field data, can be used to numerically solve pump tests for both leaky and nonleaky aquifers. A FORTRAN program on based slope-matching method was developed to obtain the transmissivity, storage coefficient, and leaky factor from pumping test data automatically. Results derived from published data show that the improved slope-matching method gives parameters close to the ones derived by the slope-matching method.

  • PDF

Oxidative Stability of Korean Traditional Cake added Ginseng (인삼을 첨가한 한과 강정의 산화안정성에 관한 연구)

  • Lee Jung-Suk;Chang Young-Sang;Oh Man-Jin
    • The Korean Journal of Community Living Science
    • /
    • v.17 no.3
    • /
    • pp.43-53
    • /
    • 2006
  • In order to improve on the stability during the storage of Han-gwa, this study measured peroxide value, AOM test of ginseng and antioxidants added to Han-gwa. 1.2% of ginseng added to Han-gwa consists of moisture (3.37%), protein(1.30%), lipids (11.54%), carbohydrate(82.45%) and ash (1.34%). The hardness of Han-gwa was 257.7 for 1.2% of ginseng added to Han-gwa and 269.8 for Han-gwa without ginseng. The expansion coefficient of Han-gwa including 1.2% of ginseng was 12.9 magnification to Bandegi, indicating that it was inversely proportioned to the amount of ginseng. The induction period of the AOM test according to the concentration of ginseng in Han-gwa was extended to $0.53{\sim}0.83$ of magnification than the test of Han-gwa without ginseng. According to changes in AOM, acid value, peroxide value and thiobarbituric acid value of Han-gwa with various packing materials, PP multilayer film packing was the most effective material for storage of Han-gwa at 30C. 1.2% of ginseng added to Han-gwa and rosemary extract in a panel test was the most effective, and using PP multilayer film packing for Han-gwa was found to be the most useful method.

  • PDF

Influence of temperature, time, and moisture content on rheology of tomatoes and pepper purees

  • Adeshina Fadeyibi;Zainab Ololamide Ayinla;Rasaq A. Ajiboye
    • Food Science and Preservation
    • /
    • v.31 no.2
    • /
    • pp.199-209
    • /
    • 2024
  • This study explored how temperature, time, and moisture content affect the rheological properties (apparent viscosity, flow behavior index, and consistency coefficient) of stored tomato and pepper purees. These purees were prepared with moisture contents of 85%, 90%, and 95% (w/v) using the hot-break method and tested over 6 days at 2-day intervals and temperatures of 5℃, 10℃, and 15℃. Results displayed distinct ranges for apparent viscosity, consistency coefficient, and flow behavior indices: tomato puree (2,519.9-4,324.6 mPa·s, 258.0-550.6 mPa·Sn, 1.80-0.48) and pepper puree (2,105.6-4,562.0 mPa·s, 268.4-580.4 mPa·Sn, 0.22-0.48). The temperature and storage time had significant (p≤0.05) effects, but moisture content did not affect these properties. Flow behavior and consistency coefficients demonstrated relative variation with apparent viscosity, indicating pseudoplastic behavior. Optimal processing and storage conditions were identified within specific ranges: 13.21-14.42℃ for 2 days with 92.22-94.23% (w/v) moisture content for pepper, and 8.42-11.77℃ for 2-6 days with 85% (w/v) moisture for tomato.

Appication of A Single Linear Reservoir Model for Flood Runoff Computation of Small Watersheds (소유역량의 홍수유출계산을 위한 단일선형 저수지 모형의 적용)

  • 김재형;윤용남
    • Water for future
    • /
    • v.19 no.1
    • /
    • pp.65-74
    • /
    • 1986
  • The purpose of this study was to investigate the applicability of Single Linear Reservoir (SLR) model for runoff computations of small river basins in Korea. In the existing watershed flood routing methods the storage coefficient(K), which is the dominant parameter in the model, has been proposed to be computed in terms of the wqtershed characteristics. However, in the prsent study, the rainfall characteristics in addition to the watershed characteristics were taken into account in the multiple regression analysis for more accurate estimation of storage coefficient. The parameters finally adopted for the regressions were the drainge are, mean stream slope of the watershed, and the duration and total dffective amount of rainfalls. To verify the applicability of SLR model the computed results by SLR model with K determined by the regression equation were compared with the observed gydrographs, and also with those by other runoff computation methods; namely, the Clark method, nakayasu's synthetic unit hydrograph method and Nash model. The results showed that the present zSLR model gave the best results among these methods in the case of small river basins, but for the whatersheds with significant draingage area the Clark method gave the best results. However, it was speculated that the SLR model could also be accurately applied for flood compuatation in large wagersheds provided that the regression for storage coefficients were made with the actual data obtained in the large river basins.

  • PDF

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Estiation of Effective Rainall for Daily Streamfiow (장기유출 해석을 위한 유효우량 추정)

  • 김태철;안병기;박승기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.2
    • /
    • pp.116-124
    • /
    • 1989
  • Based on the theory of runoff equation proposed by SCS, the actual storage capacity(Sa) as a modified retention paramater was introduced to estimate the effective rainfall for the daily streamfiow analysis. During a storm, the actual storage capacity is limited by either soil water storage or infiltration rate as precipitation increases. Therefore, it was assumed that Sa is dependent on the baseflow before storm runoff(Qb) corresponding to soil water storage and the total amount of precipitation(P) corresponding to infiltration rate of a watershed. Effective rainfalls (Direct run-offs) estimate4 from SCS equation using Sa were compared with observed effective rainfalls at 10 watersheds in Geum river watershed boundary. 1. Regression equation for Sa was supposed Sa=Co+C$_1$XP+C$_2$X Qb Regression coefficients were highly significant at the level of 0. 01 and R$^2$ were 0.57 to 0.73. 2. The adjustment of coefficient of initial abstraction was made according to the storm size. It was adjusted to 025 for 30mm or less, 0.23 for 30 to 80mm, 0.20 for 80 to 200mm, and 0.1 for 200mm or more. 3. Regression equations between estimated and observed effective rainfall showed that slopes were 0.857 to 1.029 and R$^2$ were 0.779 to 0.989,

  • PDF

Heat Transfer Chracteristics in a Fluidized bed Heat Storage System Using Encapsulated PCM (캡슐화된 PCM을 이용한 유동층 축열조에서 열전달 특성 연구)

  • Yoon, Y.H.;Han, G.Y.;Kang, Y.H.;Kwak, H.Y.;Lee, T.K.;Jeon, M.S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.89-94
    • /
    • 1998
  • The heat transfer characteristics of a fluidized bed latent heat storage system using encapsulated PCM was investigated. The cylindrical test section has the dimension of 50 mm I.D. and 40 cm in height. The phase change material(PCM) was the sodium acetate and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $2{\sim}3mm$ and melting point was $58^{\circ}C$. The instantaneous heat storage and heat release rates were determined and the instantaneous heat transfer coefficient based on the fluidized bed volume was also determined. The effect of inlet temperature and velocity of heat transfer fluid on the heat transfer coefficient was also investigated.

  • PDF

A Study on the Rainwater Quality Monitoring and the Improvement, Collection and Storage System (빗물 집수 및 저장 시스템 개선과 수질 분석 모니터링)

  • Kim, Chul-Kyung
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.

Development of Thermal Storage System in Plastic Greenhouse (I) -Development of Air-Water Heat Exchange System- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템 개발(開發)에 관(關)한 연구(硏究)(I) -수막식(水膜式) 열교환(熱交換) 시스템의 개발(開發)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.1
    • /
    • pp.14-22
    • /
    • 1990
  • For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.

  • PDF

A Study on the Shape and Size Effects on the Stability of Underground Openings (지하공동의 형상과 규모가 공동의 안정성에 미치는 영향 연구)

  • 박상찬;문현구
    • Geotechnical Engineering
    • /
    • v.14 no.1
    • /
    • pp.93-108
    • /
    • 1998
  • In this study, the analytic solutions and numerical methods were used to estimate the shape and size effects on the stability of underground openings. The stability of underground openings was evaluated by scrutinizing the effects of the rock mass quality, the state of in-situ stresses and the lateral earth pressure coefficient on the displacement, the stress concentration and the plastic region developed in the vicinity of the openings. The analytic solutions have shown that the stress concentration factor is inversely proportional to the radius of curvature of openings. Through parametric study on the various shapes and sizes of underground openings the characteristics of the controlling factors concerned with the stability were analyzed. Then, the study was extended to the horseshoe-shaped openings commonly used for under ground storage. Through the extended study the effects of the stress ratio and the height-towidth ratio of openings on the maximum displacement and plastic region developed around the openings were estimated. The results have shorn that the height-to-width ratio of domestic storage caverns can be increased economically without stability problem, as far as the lateral earth pressure coefficient is appropriate.

  • PDF