With the development of industry and standard of living, the quantity of groundwater consumption has been increasing. For the analysis of groundwater, to determine the hydraulic parameters of aquifer is very important. Various numerical methods have been developed to solve aquifer tests and eliminate the subjectivity of traditional graphical type curve methods. The slope-matching method, which matches the slope of the Theis type curve to the slope of the field data, can be used to numerically solve pump tests for both leaky and nonleaky aquifers. A FORTRAN program on based slope-matching method was developed to obtain the transmissivity, storage coefficient, and leaky factor from pumping test data automatically. Results derived from published data show that the improved slope-matching method gives parameters close to the ones derived by the slope-matching method.
In order to improve on the stability during the storage of Han-gwa, this study measured peroxide value, AOM test of ginseng and antioxidants added to Han-gwa. 1.2% of ginseng added to Han-gwa consists of moisture (3.37%), protein(1.30%), lipids (11.54%), carbohydrate(82.45%) and ash (1.34%). The hardness of Han-gwa was 257.7 for 1.2% of ginseng added to Han-gwa and 269.8 for Han-gwa without ginseng. The expansion coefficient of Han-gwa including 1.2% of ginseng was 12.9 magnification to Bandegi, indicating that it was inversely proportioned to the amount of ginseng. The induction period of the AOM test according to the concentration of ginseng in Han-gwa was extended to $0.53{\sim}0.83$ of magnification than the test of Han-gwa without ginseng. According to changes in AOM, acid value, peroxide value and thiobarbituric acid value of Han-gwa with various packing materials, PP multilayer film packing was the most effective material for storage of Han-gwa at 30C. 1.2% of ginseng added to Han-gwa and rosemary extract in a panel test was the most effective, and using PP multilayer film packing for Han-gwa was found to be the most useful method.
Adeshina Fadeyibi;Zainab Ololamide Ayinla;Rasaq A. Ajiboye
Food Science and Preservation
/
v.31
no.2
/
pp.199-209
/
2024
This study explored how temperature, time, and moisture content affect the rheological properties (apparent viscosity, flow behavior index, and consistency coefficient) of stored tomato and pepper purees. These purees were prepared with moisture contents of 85%, 90%, and 95% (w/v) using the hot-break method and tested over 6 days at 2-day intervals and temperatures of 5℃, 10℃, and 15℃. Results displayed distinct ranges for apparent viscosity, consistency coefficient, and flow behavior indices: tomato puree (2,519.9-4,324.6 mPa·s, 258.0-550.6 mPa·Sn, 1.80-0.48) and pepper puree (2,105.6-4,562.0 mPa·s, 268.4-580.4 mPa·Sn, 0.22-0.48). The temperature and storage time had significant (p≤0.05) effects, but moisture content did not affect these properties. Flow behavior and consistency coefficients demonstrated relative variation with apparent viscosity, indicating pseudoplastic behavior. Optimal processing and storage conditions were identified within specific ranges: 13.21-14.42℃ for 2 days with 92.22-94.23% (w/v) moisture content for pepper, and 8.42-11.77℃ for 2-6 days with 85% (w/v) moisture for tomato.
The purpose of this study was to investigate the applicability of Single Linear Reservoir (SLR) model for runoff computations of small river basins in Korea. In the existing watershed flood routing methods the storage coefficient(K), which is the dominant parameter in the model, has been proposed to be computed in terms of the wqtershed characteristics. However, in the prsent study, the rainfall characteristics in addition to the watershed characteristics were taken into account in the multiple regression analysis for more accurate estimation of storage coefficient. The parameters finally adopted for the regressions were the drainge are, mean stream slope of the watershed, and the duration and total dffective amount of rainfalls. To verify the applicability of SLR model the computed results by SLR model with K determined by the regression equation were compared with the observed gydrographs, and also with those by other runoff computation methods; namely, the Clark method, nakayasu's synthetic unit hydrograph method and Nash model. The results showed that the present zSLR model gave the best results among these methods in the case of small river basins, but for the whatersheds with significant draingage area the Clark method gave the best results. However, it was speculated that the SLR model could also be accurately applied for flood compuatation in large wagersheds provided that the regression for storage coefficients were made with the actual data obtained in the large river basins.
Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
Journal of Bio-Environment Control
/
v.26
no.4
/
pp.353-360
/
2017
In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.
Magazine of the Korean Society of Agricultural Engineers
/
v.31
no.2
/
pp.116-124
/
1989
Based on the theory of runoff equation proposed by SCS, the actual storage capacity(Sa) as a modified retention paramater was introduced to estimate the effective rainfall for the daily streamfiow analysis. During a storm, the actual storage capacity is limited by either soil water storage or infiltration rate as precipitation increases. Therefore, it was assumed that Sa is dependent on the baseflow before storm runoff(Qb) corresponding to soil water storage and the total amount of precipitation(P) corresponding to infiltration rate of a watershed. Effective rainfalls (Direct run-offs) estimate4 from SCS equation using Sa were compared with observed effective rainfalls at 10 watersheds in Geum river watershed boundary. 1. Regression equation for Sa was supposed Sa=Co+C$_1$XP+C$_2$X Qb Regression coefficients were highly significant at the level of 0. 01 and R$^2$ were 0.57 to 0.73. 2. The adjustment of coefficient of initial abstraction was made according to the storm size. It was adjusted to 025 for 30mm or less, 0.23 for 30 to 80mm, 0.20 for 80 to 200mm, and 0.1 for 200mm or more. 3. Regression equations between estimated and observed effective rainfall showed that slopes were 0.857 to 1.029 and R$^2$ were 0.779 to 0.989,
Yoon, Y.H.;Han, G.Y.;Kang, Y.H.;Kwak, H.Y.;Lee, T.K.;Jeon, M.S.
Solar Energy
/
v.18
no.3
/
pp.89-94
/
1998
The heat transfer characteristics of a fluidized bed latent heat storage system using encapsulated PCM was investigated. The cylindrical test section has the dimension of 50 mm I.D. and 40 cm in height. The phase change material(PCM) was the sodium acetate and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $2{\sim}3mm$ and melting point was $58^{\circ}C$. The instantaneous heat storage and heat release rates were determined and the instantaneous heat transfer coefficient based on the fluidized bed volume was also determined. The effect of inlet temperature and velocity of heat transfer fluid on the heat transfer coefficient was also investigated.
In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.
For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.
In this study, the analytic solutions and numerical methods were used to estimate the shape and size effects on the stability of underground openings. The stability of underground openings was evaluated by scrutinizing the effects of the rock mass quality, the state of in-situ stresses and the lateral earth pressure coefficient on the displacement, the stress concentration and the plastic region developed in the vicinity of the openings. The analytic solutions have shown that the stress concentration factor is inversely proportional to the radius of curvature of openings. Through parametric study on the various shapes and sizes of underground openings the characteristics of the controlling factors concerned with the stability were analyzed. Then, the study was extended to the horseshoe-shaped openings commonly used for under ground storage. Through the extended study the effects of the stress ratio and the height-towidth ratio of openings on the maximum displacement and plastic region developed around the openings were estimated. The results have shorn that the height-to-width ratio of domestic storage caverns can be increased economically without stability problem, as far as the lateral earth pressure coefficient is appropriate.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.