• Title/Summary/Keyword: Storage Units

Search Result 310, Processing Time 0.025 seconds

Optimal Generation Planning Including Pumped-Storage Plant Based on Analytic Cost Function and Maximum Principle (해석적 비용함수와 최대원리리에 의한 양수운전을 포함하는 최적전원계획)

  • 박영문;이봉용
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.8
    • /
    • pp.308-316
    • /
    • 1985
  • This paper proposes an analytic tool for long-term generation expansion planning based on the maximum principle. Many research works have been performed in the field of generation expansion planning. But few works can be found with the maxinmum principle. A recently published one worked by professor Young Moon Park et al. shows remarkable improvements in modeling and computation. But this modeling allows only thermal units. This paper has extended Professor Park's model so that the optimal pumped-storage operation is taken into account. So the ability for practical application is enhanced. In addition, the analytic supply-shortage cost function is included. The maximum principle is solved by gradient search due to its simplicity. Every iteration is treated as if mathematical programming such that all controls from the initial to the terminal time are manipulated within the same plane. Proposed methodology is tested in a real scale power system and the simulation results are compared with other available package. Capability of proposed method is fully demonstrated. It is expected that the proposed method can be served as a powerful analytic tool for long-term generation expansion planning.

  • PDF

A Study of Economic Generation Planning for operating Power systems with Dispersed Generation (분산형 전원의 배전계통 연계시 경제적 발전 계획 수립에 대한 연구)

  • Kim, Ji-Hong;Jung, Hyeon-Soo;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1453-1455
    • /
    • 1999
  • This paper presents an economical generation planning for operating power systems with dispersed generation. As dispersed generation introduced into an electric power distribution system, the power system will be complicated and have much variable aspects. So there is need for developing new generation scheduling. In this paper, the proposed method is tested for distribution system with two battery storage resources. Optimal generation planning of 15 thermal units in 24-hours is achieved by improved genetic algorithm. Also, to show its effectiveness, the results are compared with those of not including battery storage resources.

  • PDF

Energy Consumption Scheduling in a Smart Grid Including Renewable Energy

  • Boumkheld, Nadia;Ghogho, Mounir;El Koutbi, Mohammed
    • Journal of Information Processing Systems
    • /
    • v.11 no.1
    • /
    • pp.116-124
    • /
    • 2015
  • Smart grids propose new solutions for electricity consumers as a means to help them use energy in an efficient way. In this paper, we consider the demand-side management issue that exists for a group of consumers (houses) that are equipped with renewable energy (wind turbines) and storage units (battery), and we try to find the optimal scheduling for their home appliances, in order to reduce their electricity bills. Our simulation results prove the effectiveness of our approach, as they show a significant reduction in electricity costs when using renewable energy and battery storage.

Optimization of Pumped-Storage Energy in Operation Aspect Using the Analytic Cost Function (전선차용계면에서의 아수발전성 최적화를 위한 해석적 앨고리즘에 관한 연구)

  • 박영문;서보혁
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.5
    • /
    • pp.176-182
    • /
    • 1983
  • This paper derives a newly neveloped analytic optimal condition to minimize the operating cost of a generation system in the aspect of Power System Planning, When the system includes pumped-storage units. The analytic optimal condition is derived by defferentiating the analytic cost function, Which were obtained by assuming the load and generating as Gaussian random variables, with respect to the variations of pumping energy. The condition is resulted in very simple form and various optimization techniques can be used. The simulation results of a case study were compared with the results of the conventional methods to prove the usefulness of the algorithm.

Fault Detection and Diagnosis of the Deaerator Level Control System in Nuclear Power Plants

  • Kim Kyung Youn;Lee Yoon Joon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.73-82
    • /
    • 2004
  • The deaerator of a power plant is one of feedwater heaters in the secondary system, and it is located above the feedwater pumps. The feedwater pumps take the water from the deaerator storage tank, and the net positive suction head(NSPH) should always be ensured. To secure the sufficient NPSH, the deaerator tank is equipped with the level control system of which level sensors are critical items. And it is necessary to ascertain the sensor state on-line. For this, a model-based fault detection and diagnosis(FDD) is introduced in this study. The dynamic control model is formulated from the relation of input-output flow rates and liquid-level of the deaerator storage tank. Then an adaptive state estimator is designed for the fault detection and diagnosis of sensors. The performance and effectiveness of the proposed FDD scheme are evaluated by applying the operation data of Yonggwang Units 3 & 4.

Parallel Control of Mini Ice Storage Air Conditioner Using LonWorks System (LonWorks 시스템을 이용한 소형빙축열 에어컨의 병렬 제어)

  • Kim, Hong-Ryeol;Cho, Sung-Kyu;Chung, Nam-Jong;Kim, Dae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2358-2361
    • /
    • 2003
  • In this paper, parallel control method that enables coordinating operations of multiple mini ice storage air conditioner is proposed based on LonWorks system. The proposed parallel control method is a kind of master/slave control method based on LonTalk network communication. In the control method, master controller leading whole system operations is determined by date to avoid the disproportion of outdoor unit operations. In addition to the above, duty shift control method is proposed to avoid redundant operations of outdoor units and to equalize the operation frequencies of them. Through some simulation tests, the proposed parallel control method and the duty shift control method are evaluated and the efficiencies of them are validated by comparing with existing methods.

  • PDF

On-line Tests of on the Yang-Yang Pumped Storage Plant for the Reactive Power Limits and the OEL Dynamics (양양양수 온라인 무효전력 운전범위 시험과 과여자제한기(OEL) 동특성 시험)

  • Kim, Dong-Joon;Moon, Young-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1343-1350
    • /
    • 2007
  • This paper describes the tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of a generation unit. The suggested test methods on reactive limit can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state unit operation condition. The on-line OEL test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to four Yang-Yang pumped storage units with 282 rated MVA each.

Application of Logistic Simulation for Transport of SFs From Kori Site to an Assumed Interim Storage Facility

  • Kim, Young-Min;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.61-74
    • /
    • 2021
  • A paradigm shift in the government's energy policy was reflected in its declaration of early closure of old nuclear plants as well as cancellation of plans for the construction of new plants. To this end, unit 1 of Kori Nuclear Power Plant was permanently shut down and is set for decommission. Based on these changes, the off-site transport of spent fuels from nuclear power plants has become a critical issue. The purpose of this study is to develop an optimized method for transportation of spent fuels from Kori Nuclear Power Plant's units 1, 2, 3, and 4 to an assumed interim storage facility by simulating the scenarios using the Flexsim software, which is widely used in logistics and manufacturing applications. The results of the simulation suggest that the optimized transport methods may contribute to the development of delivery schedule of spent fuels in the near future. Furthermore, these methods can be applied to decommissioning plan of nuclear power plants.

On Realization Medical Imaging Viewer based on DICOM Standard

  • Cho, Kyu-Cheol;Kim, Jae-Joon
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.157-160
    • /
    • 2005
  • PACS is an integrated communication network system which is consists of image acquisition devices, storage archiving units, display stations, computer processors, and database management systems. In medical industry, they have been introduced the medical equipments through PACS systems based on the DICOM standard. In this paper, we have reviewed the performance of JPEG and JPEG2000 used as medical image compression and realized the transmission mode on DICOM standard.

  • PDF

Military surveillance System design using Digital video Recording Camera (디지털 녹화 감시 카메라 시스템에 의한 군사 방위 시스템 설계)

  • 조혜진;홍충효;최연성;김선우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.175-178
    • /
    • 2003
  • In this paper, proposed system use real-time MPEG-2 compression, and retrieve video from the storage using efficient indexed algorithm. System survey wide military range, diffuse situation to adjacent units, and transmit images long distance.

  • PDF