• Title/Summary/Keyword: Storage Structure

Search Result 1,591, Processing Time 0.029 seconds

IMPACT ANALYSIS OF A WATER STORAGE TANK

  • Jhung, Myung-Jo;Jo, Jong-Chull;Jeong, Sang-Jin
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.681-688
    • /
    • 2006
  • This study investigates the dynamic response characteristics of a structure impacted by a high speed projectile. The impact of a 300 kg projectile on a water storage tank is simulated by the general purpose computer codes ANSYS and LS-DYNA. Several methods to simulate the impact are considered and their results are compared. Based upon this, an alternative impact analysis method that is equivalent to an explicit dynamic analysis is proposed. The effect of fluid on the responses of the tank is also addressed.

The information system concept for thermal monitoring of a spent nuclear fuel storage container

  • Svitlana Alyokhina
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3898-3906
    • /
    • 2023
  • The paper notes that the most common way of handling spent nuclear fuel (SNF) of power reactors is its temporary long-term dry storage. At the same time, the operation of the dry spent fuel storage facilities almost never use the modern capabilities of information systems in safety control and collecting information for the next studies under implementation of aging management programs. The author proposes a structure of an information system that can be implemented in a dry spent fuel storage facility with ventilated storage containers. To control the thermal component of spent fuel storage safety, a database structure has been developed, which contains 5 tables. An algorithm for monitoring the thermal state of spent fuel was created for the proposed information system, which is based on the comparison of measured and forecast values of the safety criterion, in which the level of heating the ventilation air temperature was chosen. Predictive values of the safety criterion are obtained on the basis of previously published studies. The proposed algorithm is an implementation of the information function of the system. The proposed information system can be used for effective thermal monitoring and collecting information for the next studies under the implementation of aging management programs for spent fuel storage equipment, permanent control of spent fuel storage safety, staff training, etc.

A Study on planning of storage area considering residents' needs (거주자 요구를 고려한 수납면적에 관한 연구)

  • Lee, Se-Na;Lee, Hyun-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.193-196
    • /
    • 2006
  • The storage style has changed because of diversity of family types, improvement of cost of living, and increase of leisure time. In spite of this change, storage space has still caused discomfort since it did not consider residents' convenience. Therefore, in this study, Brand Apartments were selected, furniture detail drawing was analyzed by plan of housing size and zone to calculate storage area and capacity, and finally needs of storage space were analyzed using survey. Satisfaction of storage space was generally low and $20{\sim}30%$ increase of storage space was demanded. The reasons why the storage space was not satisfied are followed. First, storage space was insufficient. Second, the inner structure of storage space was unified. According to change of life style, needs have changed. To satisfy these needs, the inner division of storage space is planned with considering various items. In addition, development of hardware, flexible division, and priority of storage space with considering user's convenience are needed.

  • PDF

Earthquake Response Analysis of Cylindrical Liquid-Storage Tanks Considering Nonlinear Fluid-Structure Soil Interactions (비선형 유체-구조물-지반 상호작용 고려한 원통형 액체저장탱크의 지진응답해석)

  • Jin Ho Lee;Jeong-Rae Cho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.2
    • /
    • pp.133-141
    • /
    • 2024
  • Considering fluid-structure-soil interactions, a finite-element model for a liquid-storage tank is presented and the nonlinear earthquake response analysis is formulated. The tank structure is modeled considering shell elements with geometric and material nonlinearities. The fluid is represented by acoustic elements and combined with the structure using interface elements. To consider the soil-structure interactions, the near- and far-field regions of soil are modeled with solid elements and perfectly matched discrete layers, respectively. This approach is applied to the seismic fragility analysis of a 200,000 kL liquid-storage tank. The fragility curve is observed to be influenced by the amplification and filtering of rock outcrop motions at the site when the soil-structure interactions are considered.

Applicability of Beam Model among Earthquake Response Analysis Models of Liquid-Storage Tank (액체저장탱크의 지진응답해석 모델 중 빔 모델의 적용성)

  • Jin, Byeong-Moo;Jeon, Se-Jin;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.696-699
    • /
    • 2004
  • Generally, the time history analysis among seismic response analyses of a structure needs more times than static analysis. Therefore the mechanical model of a structure has been used as a simple lumped parameter model in time history analysis. For the most cases, the simple mechanical model shows the similar results to that of detailed finite element model. so it is reasonable to use the simple mode] in preliminary analysis. In seismic design of liquid storage tank, such as LNG storage tank, the lumped parameter mode] also is being used in preliminary analysis, however sometimes shows the differences to the results of detailed finite element model. Therefore in this study, the dynamic characteristics between lumped parameter model and detailed finite model is compared for the variables such as height/diameter of liquid-storage tank and thickness of wall, then the applicability of beam mode] to the seismic response analysis are evaluated for some liquid storage tanks.

  • PDF

Influence of Mg nanoparticles on Hydrogen Adsorption Behaviors of Multi-walled Carbon Nanotubes (다중벽 탄소나노튜브의 수소 흡착 거동에 대한 Mg 나노입자의 영향)

  • Yoo, Hye-Min;Park, Soo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.160-160
    • /
    • 2011
  • In this work, magnesium (Mg) nanoparticles were plated onto the surfaces of multi-walled carbon nanotubes (MWNTs) in order to investigate the effects of their presence on the high pressure hydrogen storage behaviors of the resultant Mg/MWNTs. The structure of Mg/MWNTs was characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The pore structure and total pore volumes of Mg/MWNTs were analyzed by $N_2$/77 K adsorption isotherms. The hydrogen storage behaviors of the Mg/MWNTs were investigated by BEL-HP at 298K and 100 bar. From the results, it was found that Mg particles were homogeneously distributed on the MWNT surfaces. The hydrogen storage capacity increased in proportion to the Mg content. It can be concluded that Mg paricles play an important role in hydrogen storage characteristics due to the hydrogen spillover effect.

  • PDF

Design of an Electrostatic 2-axis MEMS Stage having Large Area Platform for Probe-based Storage Devices (대면적 플랫폼을 갖는 Probe-based Storage Device(PSD)용 정전형 2축 MEMS 스테이지의 설계)

  • Chung, Il-Jin;Jeon, Jong-Up
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.3
    • /
    • pp.82-90
    • /
    • 2006
  • Recently the electrostatic 2-axis MEMS stages have been fabricated for the purpose of an application to PSD (Probe-based Storage Device). However, all of the components(platform, comb electrodes, springs, anchors, etc.) in those stages are placed in-plane so that they have low areal efficienceis, which is undesirable as data storage devices. In this paper, we present a novel structure of an electrostatic 2-axis MEMS stage that is characterized by having large area platform. for obtaining large area efficiency, the actuator part consisting of mainly comb electrodes and springs is placed right below the platform. The structure and operational principle of the MEMS stage are described, followed by a design procedure, structural and modal analyses using FEM(Finite Element Method). The areal efficiency of the MEMS stage was designed to be about 25%, which is very large compared with the conventional ones having a few percentage.

Seismic Analysis of Spent Fuel Storage Structures for PHWR Plant (중수로형 핵연료 저장대의 내진해석 방법)

  • 신태명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.338-344
    • /
    • 2003
  • The seismic analysis method of spent fuel storage structures for PHWR plant is introduced in comparison with the method for PWR plant. Investigating the structural characteristics of the storage structures, the former is vertically stacked fuel storage trays, while the latter is welded honeycomb type structure. However, as both structures are submerged and free standing, the analysis methods to anticipate the seismic response of both structures are complicated. For the better estimation of actual seismic response, how to model the dynamic properties and the structural behaviour is the key issue. In this paper, the overall procedures of the seismic modelling and stability check for seismic sliding and overturning of the two different storage structures are discussed in the viewpoint of analysis reliability

  • PDF

A Study on Characteristics of Heat Storage and Emission of Apartment Structures in Winter Season (겨울철 난방시 아파트 구조체의 축방열 특성에 대한 연구)

  • Cho, Keun-Je;Chang, Hyun-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.208-213
    • /
    • 2011
  • In the former study, it is obtained that thermal storage effect of the apartment structure is the disadvantage to maintain comfort indoor thermal environment. However, because the thermal storage effect can be changed of its aspect in heating season, field measurement at the same apartment with the measurement in summer season was conducted in winter season. As results, thermal storage effect of apartment structure was the disadvantage in winter season, too.

  • PDF