• Title/Summary/Keyword: Storage Conditions

Search Result 2,518, Processing Time 0.026 seconds

Rapid Fermentation of Fish Sauce and Its Kinetics (어장유의 속성발효와 동력학적 고찰)

  • KIM Byeong-Sam;PARK Sang-Min;CHOI Soo-Il;KIM Chang-Yang;HAN Bong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.1
    • /
    • pp.10-19
    • /
    • 1986
  • A study on the rapid fermentation of fish sauce has been carried out for effective utilization of sardine. The frozen sardine was thawed at room temperature, chopped, homogenized with equal amount of water and then hydrolyzed by addition of commercial proteolytic enzymes such as bromelain, papaya protease, ficin and a enzyme mixture under different conditions of hydrolysis. The effect of wheat gluten for masking fishy odor and color development during thermal treatment were also tested. The reaction mixture was heated for 30 minutes at $100^{\circ}C$ for enzyme inactivation, pasteurization and color development and then centrifuged for 20 minutes at 4,000 rpm. Finally, table salt and benzoic acid were added for bacteriostatic effect. The results were summarized as follows ; 1. The hydrolyzing temperature, time, pH and the concentration of enzymes based on the weight of whole sardine for optimal hydrolysis were as follows: autolysis, $52.5^{\circ}C$, 4 hours, pH 8.0: with $0.25\%$ bromelain, $52.5^{\circ}C$, 4 hours, pH 6.6 :with $0.25\%$ ficin, $52.5^{\circ}C$, 4 hours, pH 6.8: with $0.3\%$ papaya protease, $52.5^{\circ}C$, 4 hours, pH 6.6: with $6\%$ enzyme mixture, $52.5^{\circ}C$, 4 hours, pH 6.9, respectively. But pH control was not much beneficial in increasing yield. 2. The hydrolytic reaction of chopped sardine with proteolytic enzymes could be interpreted as a first order reaction that devided into 2 periods with different reaction rate constsnts. $Q_{10}$ values of the first period prior to 4 hours were 1.23 to 1.31, and those of post 4 hours were 1.25 to 1.55. The corresponding activation energies were $1.81{\times}10^4\;to\;2.34{\times}10^4\;kJ/kmol$ and $1.92{\times}10^4\;to\;3.77{\times}10^4\;kJ/kmol$, respectively. 3. The reasonable amount of $75\%$ vital wheat gluten for addition was $9\%$ of chopped sardine. 4. The dark brown color was mainly developed during the thermal treatment for 30 minutes at $100^{\circ}C$ and not changed during storage.

  • PDF

CHANGES IN CONTENTS OF AMINES IN THE DARK-FLESHED FISH MEAT DURING PROCESSING AND STORAGE (적색육 어류의 저장 및 가공중의 Amino류의 변화 (I) 고등어${\cdot}$전어${\cdot}$정어리 염장 및 건제품의 DMA와 TMA함량)

  • AHN Cheol-Woo;CHOI Su-An;PARK Yeung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.245-253
    • /
    • 1979
  • Trimethylamine and dimethylamine contents of salted, hot-air dried, sun dried and boiled-dried samples of three commercial fishes, common mackerel, gizzard-shad and sardine, were analyzed and quantitatively compared at two different temperature conditions. The formation of both secondary amines was more rapid at $25^{\circ}C$ than at $10^{\circ}C$. And the content of dimethylamine in small sardine was comparatively higher than that in the other samples at both temperatures. Residual amounts of trimethylamine oxide of Halted common mackerel, gizzard-shad and boiled-dried small sardine were relatively higher than those of the other samples. Trimethylamine contents of sun dried samples were relatively higher than in the other samples, while those of boiled-dried small sardine was comparatively lower than those of the others. Dimethylamine content of sun dried samples were higher than those of the other samples, whereas those of boiled-dried small sardine and salted common mackerel were comparatively lower than those of the other samples.

  • PDF

Current conditions regarding dental infection management recognition of students in the department of dental hygiene (치위생(학)과 학생의 치과감염관리에 관한 인식현황)

  • Lee, Yeun-Kyoung;Kim, Soon-Duck
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.468-478
    • /
    • 2009
  • This research was performed to provide basic data for the development of infection related dental hygiene studies by surveying the current condition of recognition among students in the department of dental hygiene toward hospital infection management while receiving the following results by using a personal self-administered survey method targeting 303 students in the department of dental hygiene from certain areas. 1. With the current condition of recognition on the sanitization and sterilization of instruments among students in the department of dental hygiene(study), the rate at which surgical instruments are to be sterilized with autoclaves was 79.9% which was relatively higher than other instruments while it was shown that prosthetic instruments for treatment was 56.4%, conservative instruments for treatment was 51.8%, and ultrasonic scaler tip was 51.1% while the way syringe tips(36.1%) and the dental anesthetic apparatus(27.9%) were revealed to require sanitization by alcohol. 2. The 'hand wash' area was the highest with 4.71 while the 'materials and environment management' area and 'equipment management' area appeared high respectively with 4.43 and 4.41. 3. With the current condition of recognition on equipment management, 'equipments used for contagious patients are separately washed after a one-time use and must be sterilized or separated-and-discarded' was the highest with 4.82 while 'sterilization equipments with humidity or water on it are considered contaminated and are not used' showed the lowest recognition level with 3.90. 4. Regarding the current condition of materials and environment management, 'contagious and general trash are separated and discarded' was the highest with 4.70 while 'the refrigerator for medicine storage is cleaned on a regular basis once a month' was revealed as the lowest with 4.11. 5. With the current condition of recognition on hand washing, 'one must wash their hands after coming in contact with contagious patients, was the highest with 4.90 while washing hands after taking off gloves' appeared as the lowest with 4.51 point. To conclude department of dental hygiene there is to infection management and necessary about organization disinfecting and pasteurization to strengthen an education in order raising a stamp helping practical ratio about the infection management which whole, is from presence at a sickbed and connection does and about the infection management which is substantial and educational program development leads feed with the fact that deepening studying which is continuous must become accomplished becomes.

  • PDF

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.

Analytical Method Development and Monitoring of Residual Solvents in Dietary Supplements (건강기능식품 중 잔류용매 분석법 개발 및 모니터링)

  • Lee, Hwa-Mi;Shin, Ji-Eun;Jang, Young-Mi;Kim, Hee-Yun;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.390-397
    • /
    • 2010
  • Residual solvents in foods are defined as organic volatile chemicals used or produced in manufacturing of extracts or additives, or functional foods. The solvents are not completely eliminated by practical manufacturing techniques and they also may become contaminated by solvents from packing, transportation or storage in warehouses. Because residual solvents have no nutritional value but may be hazardous to human health, there is a need to remove them from the final products or reduce their amounts to below acceptable levels. The purpose of this study was to develop and evaluate an analytical method for the screening of residual solvents in health functional foods. Furthermore, the aim of this study was to constitute a reasonable management system based on the current state of the market and case studies of foreign countries. Eleven volatile solvents such as MeOH, EtOH, trichloroethylene and hexane were separated depending on their column properties, temp. and time using Gas Chromatography (GC). After determining the GC conditions, a sample preparation method using HSS (Head Space Sampling) was developed. From the results, a method for analyzing residual solvents in health functional foods was developed considering matrix effect and interference from the sample obtained from the solution of solvents-free health functional foods spiked with 11 standards solutions. Validation test using the developed GC/HSS/MS (Mass Spectrometry) method was followed by tests for precision, accuracy, recovery, linearity and adequate sensitivity. Finally, examination of 104 samples grouped in suits was performed by the developed HSS/GC/MS for screening the solvents. The 11 solvents were isolated from health functional foods based on vapor pressure difference, and followed by separation within 15 minutes in a single run. The limt of detection (LOD), limit of quantification (LOQ), recovery and coefficient of variation (C.V.) of these compounds determined by the HSS/GC/MS were found to be 0.1 pg/mL, 0.1-125 pg/g, 51.0-104.6%, and less than 15%, respectively. Using the developed HSS/GC/MS method, residual solvent from 16 out of 104 health functional products were detected as a EtOH. This method therefore seems t o be a valuable extension ofanalytical method for the identification of residual solvents in health functional food.

Choosing Quality Indicators for Quality Prediction of Frozen Green Pumpkin in Distribution (냉동 애호박의 유통 중 품질예측을 위한 품질지표 선정)

  • Lee, Hye-Ok;Lee, Young-Joo;Kim, Ji-Young;Kwon, Ki-Hyun;Cha, Hwan-Soo;Kim, Byeong-Sam
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.325-332
    • /
    • 2013
  • We aimed to determine the quality indicators for quality prediction of frozen green pumpkin in distribution. Freshly harvested green pumpkin slices were blanched under optimal conditions (confirmed in a preliminary experiment), quick-frozen at $-40^{\circ}C$ for 24 h, and stored at 0, -5, -15, and $-25^{\circ}C$. The correlation between each quality characteristic and the sensory preference rate was analyzed. There was a significant correlation between storage temperature-related drip rate and preference rate across all temperatures, except at$-25^{\circ}C$. Hunter values, a and b, showed relatively high correlation coefficient values at -5, -15, and $-25^{\circ}C$. Therefore, a change in the Hunter values should be considered when storing green pumpkin, because of their significant correlation with changes in the sensory preference and drip rates. Furthermore, they should be applied as quality indicators for the quality prediction of frozen green pumpkin in distribution.

Evaluation of Analyzer and Measurement Conditions of Blood Ammonia (혈중 암모니아의 측정조건과 분석기기의 평가)

  • Kim, Sang-Su;Kim, Myong Soo;Lee, Seung Mo;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.68-73
    • /
    • 2016
  • Ammonia is very toxic, and causes neuronal damage via excitotoxicity, oxidative stress, and inflammation. Because the liver is the primary organ for ammonia metabolism, compromised liver function can result from inborn errors of metabolism. Measurement of blood ammonia has some limitations. Recently, several laboratories examined possible concurrent increases in plasma ammonia. However, the collection, handling, storage, and analysis of blood samples are all potential sources of error. For evaluation of rapidity and reliability of measurement of blood ammonia, the DRI-CHEM 100 (Fuji Film Co., Japan) and COBAS 8000 (Roche Diagnostic Ltd., Switzerland) analyzer were used for analysis of ammonia level values. The results of this study detected a high correlation between analyzer. Therefore, one-step measurement was suitable for ammonia analysis. After sampling of the ammonia in the time slot for measurement an increase to 46.5, 57.4, and 79.0 (${\mu}g/dL$) was observed at 30, 90, and 180 minutes. In addition, specific capacity of the ammonia, 7, 10, and 13 (${\mu}L$), was measured as 39, 46, and 43 (${\mu}g/dL$), respectively, and the FDC-100 analyzer was more effective in $10{\mu}L$ (p<0.001). In conclusion, the evaluated analysis may offer useful information for clinical application.

Migration Measurement of Volatile Organic Compounds (VOCs) from Polystyrene-made Food Containers into Distilled Water (폴리스티렌 식품용기로부터 증류수로 용출되는 휘발성유기화합물의 분석)

  • Kim, Nam-Hoon;Kim, Ae-Kyeong;Cho, Tae-Hee;Park, Kyung-Ai;Kwak, Jae-Eun;Kim, Ji-Young;Kim, Il-Young;Chae, Young-Joo;Kim, Min-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.203-208
    • /
    • 2010
  • In this study, the level of migration of 5 kinds of volatile organic compounds (VOCs) (toluene, styrene, ethylbenzene, isopropylbenzene and n-propylbenzene) into distilled water from polystyrene-made food containers was measured using Purge&Trap combined with GC/FID. The contents of the VOCs which have regulatory limits in Korea food code only for material specification were determined under three exposure conditions which were 30 min at $60^{\circ}C$, 30 min at $95^{\circ}C$ and actual situation of instant noodle intake. The calibration curve of 5 compounds showed good linearity ($^r2$ = 0.9976~0.9995) within the concentration range of 1~50 ng/mL. The limit of detection (LOD) and limit of quantification (LOQ) were validated at range of 0.041~0.092 and 0.135~0.304 ng/mL, respectively. The average migration contents of 5 compounds were below 5 ng/mL except for styrene. The average contents of styrene were highly detected at $95^{\circ}C$ for 30 min exposure (52.71 ng/mL). Under actual condition at instant noodle intake, the average contents of styrene was 17.23 ng/mL. The results demonstrated that the migration rate of VOCs was related to storage temperature and time.

Studies on the Thermal Processing of Cooked Rice Packed in Retort Pouch (레토르트 파우치 미반(米飯)의 가열살균에 관한 연구)

  • Lee, Shin-Young;Lee, Sang-Kyu;Pyun, Yu-Ryang;Yu, Ju-Hyun;Han, Byung-Kon
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.153-159
    • /
    • 1981
  • A study was carried out to determine the optimal sterilization conditions of cooked rice packed in retort pouch and processed in a steam-air system retort. The cooked rice packed in retort pouch in various thickness (15, 20 and 25 mm) was processed at various heating temperature (110, 115 and $120^{\circ}C$) with $F_0$-value 6.0. In order to evaluate quality change during the thermal prosessing, C-values, based on z-value $33^{\circ}C$ and $F_0$ value 6.0, were also calculated at surface, center and mass average temperatures. Subsequent storage study revealed that the cooked rice packed in 15 mm thickness and processed at $120^{\circ}C$ with$F_0$-value 6.0 could be held without any spoilage and color change, when stored for 6 months at $38{\pm}1^{\circ}C$ under saturation humidity.

  • PDF

Residue Levels of Chlorpyrifos and Chlorothalonil in Apples at Harvest (Chlorpyrifos 및 Chlorothalonil의 사과 생산단계별 잔류특성)

  • Kim, Young-Sook;Park, Ju-Hwang;Park, Jong-Woo;Lee, Young-Deuk;Lee, Kyu-Seung;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.130-136
    • /
    • 2003
  • An organophosphorus insecticide, chlorpyrifos and an arylnitrile fungicide, chlorothalonil commonly used far apple were subjected to a residual investigation under field conditions to ensure safety of terminal residues at harvest. After pesticides were applied at standard rate in apple tree fer 15 days for chlorpyrifos and 30 days far chlorothalonil, persistence of their residues in apple was investigated by several interval. At harvest, residual concentrations of chlorpyrifos and chlorothalonil in apple were 1.3 and 2.4mg/kg, respectively, and the residue levels were higher than MRL 1.0 mg/kg in Korea. As well fitted by the first-oder kinetics, biological half-lives of the pesticide residues in apple were 9.3 days for chlorpyrifos and 32.2 days for chlorothalonil. During the storage, half-lives of chlorpyrifos and chlorothalonil were 35.0 and 56.3days at room temperature, and 120.7 and 182.8 days at 412, respectively. Distribution of chlorpyrifos residue in flesh, fruit skin and stalk cavity of each apple corresponded to 0.1% 22.8% and 77.1%, respectively. In case of chlorothalonil, residue in flesh, fruit skin and stalk cavity was 4.4%, 10.4% and 85.2%, respectively.