• Title/Summary/Keyword: Stimulus pulse

Search Result 67, Processing Time 0.025 seconds

EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE (저출력 레이저조사가 동통반응에 미치는 영향)

  • Kim, Sung-Kyo;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF

Cardiovascular response to surprise stimulus (놀람 자극에 대한 심혈관 반응)

  • Eom, Jin-Sup;Park, Hye-Jun;Noh, Ji-Hye;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.147-156
    • /
    • 2011
  • Basic emotions such as happiness, sadness, anger, fear, and disgust have been widely used to investigate emotion-specific autonomic nervous system activity in many studies. On the contrary, surprise emotion, Suggested also as one of the basic emotions suggested by Ekman et al. (1983), has been least investigated. The purpose of this study was to provide a description of cardiovascular responses on surprise stimulus using electrocardiograph (ECG) and photoplethysmograph (PPG). ECG and PPG were recorded from 76 undergraduate students, as they were exposed to a visuo-acoustic surprise stimulus. Heart rate (HR), standard deviation of R-R interval (SD-RR), root mean square of successive R-R interval difference (RMSSD-RR), respiratory sinus arrhythmia (RSA), finger blood volume pulse amplitude (FBVPA), and finger pulse transit time (FPTT) were calculated before and after the stimulus presentation. Results show significant increase in HR, SD-RR, and RMSSD-RR, decreased FBVPA, and shortened FPTT. Evidence suggests that surprise emotion can be characterized by vasoconstriction and accelerated heart rate, sympathetic activation, and increased heart rate variability, parasympathetic activation. These results can be useful in developing an emotion theory, or profiling surprise-specific physiological responses, as well as establishing the basis for emotion recognition system in human-computer interaction.

  • PDF

The Effect of Electrical Stimulation Applied in Dominant Forearm on Autonomic Nervous System Response of Both Hands (우세측 전완에 적용한 전기자극이 양쪽 손 자율신경계 반응에 미치는 효과)

  • Lee, Dong-Geol;Seo, Sam-Ki;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effect of electrical stimulation applied in dominant forearm on autonomic nervous system response of both hands. Methods : Fourteen healthy subjects (women) received low frequency-high intensity electrical stimulation to one forearm. The subjects assigned to two groups; a ipsilateral stimulation group (n=7) and a contralateral stimulation group (n=7). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was set as 15 minutes. Measuring items were the skin conduction velocity, the blood flow, and the pulse rate, which were measured total 3 times (pre, post, and post 10 min.). Results : The skin conduction velocity showed a significant difference according to the change of the time in both hands, but there was no significant difference according to time in the blood flow, and the change of the pulse frequency regardless of stimulus side. Conclusion : These results demonstrate that the low frequency-high intensity electrical stimulation applied dominant forearm can increase selectively only with the skin conduction velocity, which may be helpful for the activation of the sudomotor function of both hands by the activation of sympathetic nerve.

A Study on the Functional Electrical Stimulation (기능적 전기 자극에 대한 고찰)

  • Lim, Jong-Soo;Kim, Soon-Hee;Song, Young-Wha
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.187-199
    • /
    • 1999
  • Functional Electrical Stimulation (FES) is used for muscle reeducation, reduction of spasticity, delay of atrophy, and muscle strengthening. FES stronger stimulation than other forms of electrical stimulation. The efficacy of FES in improving function has been substantiated in the literature. Treatment programs employing FES - activation of muscular tissue through the intact peripheral nervous system - can be broken into five major categories, according to the goal of treatment. These broad areas would include the use of FES to: (1) a direct excitation onto the alpha motoneuron, through peripheral stimulation of the Ia myotatic sensory system and ascending afferent information, which will be integrated at conscious and subconscious level of the CNS. (2) The quality of a stimulated muscle contraction is determined by combination of many parameters, including stimulus amplitude, pulse duration, stimulus frequency, and duty cycle. (3) A unit that has a pulse duration between 200 and $400{\mu}sec$ will be more than adequate for FES applications. (4) The neuromuscular plasticity is critically important to return of function using muscle re-education and facilitation applications. (5) Prior to using FES as an electrical orthosis, the patient should build up endurance in the muscles to be stimu1ated during the gait cycle.

  • PDF

Effective PPG Signal Processing Method for Detecting Emotional Stimulus (감성 자극 판단을 위한 효과적인 PPG 신호 처리 방법)

  • Oh, Dong-Gi;Min, Byung-Seok;Kwon, Sung-Oh;Kim, Hyun-Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.393-402
    • /
    • 2012
  • In this study, we propose a signal processing algorithm to measure the arousal level of a human subject using a PPG(Photoplethysmography) sensor. From the measured PPG signals, the arousal level is determined by PPI(Pulse to Pulse Interval) and discrete-time signal processing. We ran psychophysical experiments displaying visual stimuli on TV display while measuring PPG signal from a finger, where the nature landscape scenes were used for restorative effect, and the urban environments were used to stimulate the stress. However, the measured PPG signals may include noise due to subject movement and measurement error, which results in incorrect detections. In this paper, to mitigate the noise impact on stimulus detection, we propose a detecting algorithm using digital signal processing methods and statistics of measured signals. A filter is adopted to remove a high frequency noise and adaptively designed taking into account the statistics of the measured PPG signals. Moreover we employ a hysteresis method to reduce the distortion of PPI in decision of emotional. Via experiment, we show that the proposed scheme reduces signal noise and improves stimulus detection.

A Study of Impulse Buying and Marketing Stimulus Factors of Clothing Consumer (의류 소비자의 충동구매와 마케팅 자극요인에 관한 연구)

  • 강경자;정수진
    • Journal of the Korean Society of Costume
    • /
    • v.36
    • /
    • pp.25-41
    • /
    • 1998
  • The purpose of this research was to study four impulse buying dimensions and planned buying, marketing stimulus factors in store, buying im-pulse and impulse buying of female consumer. The female consumers were divided into three groups, i.e., college students, housewives and workingwomen. 408 women living in Kyung Nam were selected as respondents by convenience sampling methods. The results of this research can be summarized as follows. 1. The overall impulses were stronger for college students and workingwomen than house-wives. The impulse buying dimensions were different according to the status of women. 2. Buying impulse and impulse buying of clothing were more likely to be for college students and working women than housewives. 3. The display in the store gave the information to the three groups equally. These infor-mations helped to make the impulse buying. 4. The marketing stimulus factors were different according to the status of respondents. Sensitive and aesthetic factors were important for college students and workingwomen, and the utility of clothing were important for house-wives. The color of clothing, the discount of regular price and the low price had the same meanings to the three groups. 5. Impulse buying dimensions were effected by the marketing stimulus factors. 6. The fashionable products, the use of credit card, famous brand, gracious display of clothing and the kind services of salesman were the common factors that stimulate the consumer to buy the clothings. But the color and design of products had more effect on the college students, and the discount of regular price and the utility of clothing were more important for the workingwomen. The color and the utility of clothing were stimulus factors for the housewives.

  • PDF

Acceleration of Cell Proliferation and Gene Expression in Human Chondrosarcoma Cells Stimulated by Strong Pulse Magnetic Field

  • Shin, Sung Chul;Chung, Eui Ryong;Hwang, Do Guwn
    • Journal of Magnetics
    • /
    • v.18 no.1
    • /
    • pp.14-20
    • /
    • 2013
  • For the treatment of osteoarthritis, pulsed electromagnetic field stimulus has been suggested as a useful therapeutic method in rehabilitative medicine. Most studies have been performed under low-frequency and low-energy to find out biological properties for stimulating chondrocyte with pulsed magnetic field. In this study, the effect of strong pulse magnetic field on the human chondrosarcoma cells (SW-1353) has been investigated by means of cell counting, morphologies, and gene expression of cartilage extracellular matrix genes. The SW-1353 cells were exposed under the field intensities of 270, 100, 55, 36, and 26 mTesla during 6 hours a day in 5 consecutive days. The pulse magnetic field with an LRC oscillating signal has the pulse width of 0.126 msec and stimulation period of 1 sec. For the 270 and 100 mTesla stimulation, the cell proliferation significantly increased in 21-24% as compared with the non-stimulated cells. Gene expression of cartilage extracellular matrix genes (ACAN, COMP and COL2A1) was assayed by quantitative real time-PCR method. The ACAN gene expression showed a significant brightness, which means the increase on gene expression, compared with the non-stimulated cells. Our results suggest that the strong pulse magnetic field stimulation can be utilized to accelerate cell proliferation and gene expression on human chondrosarcoma cells.

Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina

  • Jungryul Ahn;Yongseok Yoo;Yong Sook Goo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.27 no.6
    • /
    • pp.541-553
    • /
    • 2023
  • Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.

Characterization of sounds produced by 3 sciaenid species (민어과 어류의 명음에 관한 음향학적 특성)

  • Lee, Kyoung-Hoon;Yang, Yong-Soo;Kim, Jin-Ku;An, Heui-Chun;Shin, Jong-Keun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.3
    • /
    • pp.206-211
    • /
    • 2007
  • The sciaenid species, which has swimbladder, generates sounds by vibrating in its length wards when spawning or getting stimulus from something else. This research analyzed on sound frequency characteristics relatives to their swimbladder length of three sciaenid species, yellow croaker(Larimichthys polyactis), brown croaker(Miichthys miiuy), and white flower croaker(Nibea albiflora). As results, the dominant frequency for yellow croaker ranged over 38.08 to 141.60Hz in wide frequency band, and the averaged pulse duration expressed in $280.3{\pm}156.0ms$. For brown croaker, the dominant frequency ranged in 49.80 to 59.57Hz, and the averaged pulse duration was $129.1{\pm}36.9ms$. Moreover, the dominant frequency of white flower croaker ranged in 73.24 to 86.91Hz, and the averaged pulse duration was $88.0{\pm}15.9ms$, it has shorter pulse duration than any two species. Therefore, the dominant frequency relatives to swimbladder length of sciaenidae showed that it had widely resonant characteristics and long pulse duration as in shorter swimbladder length. Additionally, for white flower croaker, we could confirm their behavior and sounds in response to production of recorded sounds using underwater speaker.

Motion-based Controlling 4D Special Effect Devices to Activate Immersive Contents (실감형 콘텐츠 작동을 위한 모션 기반 4D 특수효과 장치 제어)

  • Kim, Kwang Jin;Lee, Chil Woo
    • Smart Media Journal
    • /
    • v.8 no.1
    • /
    • pp.51-58
    • /
    • 2019
  • This paper describes a gesture application to controlling the special effects of physical devices for 4D contents using the PWM (Pulse Width Modulation) method. The user operation recognized by the infrared sensor is interpreted as a command for 3D content control, several of which manipulate the device that generates the special effect to display the physical stimulus to the user. With the content controlled under the NUI (Natural User Interface) technique, the user can be directly put into an immersion experience, which leads to provision of the higher degree of interest and attention. In order to measure the efficiency of the proposed method, we implemented a PWM-based real-time linear control system that manages the parameters of the motion recognition and animation controller using the infrared sensor and transmits the event.