• Title/Summary/Keyword: Stimulus Tester

Search Result 7, Processing Time 0.033 seconds

Stimulus Tester : Educational Learning Improvement System for IPTV Education and Entertainment Contents (IPTV의 교육 및 엔터테인먼트 콘텐츠를 위한 교육 학습 반응 시스템 (Stimulus Tester) 연구)

  • Beak, Seung-Hyun;Kwon, Dae-Hyuk;Lee, Hye-Ran
    • Journal of Internet Computing and Services
    • /
    • v.11 no.5
    • /
    • pp.71-80
    • /
    • 2010
  • The purpose of this research is to help IPTV (Internet Protocol Television) commercialization using newly produced educational contents in the area of entertainment and education which currently popular in the market. It is called, Stimulus $Tester^{TM}$, endow reaction time from the feedback of learning system, using a non-direct method, for example, a remote controller. Reaction time is the learning efficiency promotion mechanism that learner ascertain the learning condition of oneself by the time with solved questions from the solving the question in given time. Reaction time also play a key role that the learner may go through course which distribute the point to PC from Server. If this system is ready, we expect that the educational industry will gradually spread out. To verify the learning efficiency of this system, we concluded that the learning improvements, by an Internet-based and a paper-based test, of the increase by 51%, from 2.47min to 1.27min, during reaction of 7 days.

Development of an Auto Stimulus Breaker During the Electric Pulp Testing using Human Responses (전기 치수 검사 시 인체 반응을 이용한 자극 제어기의 개발)

  • 남기창;안선희;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.43-49
    • /
    • 2004
  • Electric pulp test is a method to examine the vitality of dental pulp using physical and chemical stimulation. During the pulp test, the current stimulates intradental nerve, and it makes patients painful. In this paper, we measured each activating response EMG in anterior belly of digastric muscle, voice, and finger movement during the pulp test by increasing stimulus intensity gradually. We also measured excessive stimulus time from the activating responses (EMG, voice, and finger movement) to the end of the stimulation. We measured and analyzed excessive stimulus time for each stimulus detecting method. As a result, we developed automatic stimulus breaker using the human responses to stimulus during electric pulp test. We reduced the excessive stimulus time by disconnecting the pulp tester stimulus output rapidly in 10 ms after activating human response.

MEASUREMENT OF THE EXCESSIVE STIMULUS TIME AFTER THE SENSORY THRESHOLD LEVEL DURING ELECTRIC PULP TESTING (전기 치수 검사 시 역치 자극 이후 과용(過用) 자극 시간의 측정)

  • Nam, Ki-Chang;Ahn, Seon-Hui;Kim, Soo-Chan;Kim, Deok-Won;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.226-232
    • /
    • 2004
  • Use of electric pulp testing elicits painful response in vital teeth. In this study, we examined the excessive time from pain feeling to stimulation disconnection in clinical situation. D626D (Parkell Inc., USA.) scan type electric pulp tester was used in total of 23 young healthy individuals. Each of the right central incisors and first premolars were used as testing teeth. Stimulation disconnection was achieved by EMG in anterior belly of digastric muscle, finger span, and voice and the excessive stimulation time over the sensory thresh-old was recorded. As a result, we found that the short responses before the stimulation disconnection appeared following order:EMG, finger span, and voice. The EMG disconnection is suggested to be used to reduce the excessive stimulus time in electric pulp testing.

Evaluation of the change of lower lip sensation after inferior alveolar nerve block by using the electric pulp tester (하치조신경 마취 후 전기치수검사기(Electric pulp tester)를 이용한 하순부 감각 변화 평가)

  • Ku, Myong-Suk;Kim, Jin-Wook;Jeon, Young-Hoon;Kwon, Tae-Geon;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.464-469
    • /
    • 2011
  • Introduction: As dental implant surgery is becoming increasingly popular, it has become one of the causes for the hypesthesia of the inferior alveolar nerve, along with other surgical procedures, such as a third molar extraction. In addition, it tends to cause legal problems between the operator and patient. Therefore, there must be a proper method that is reliable, objective and economical to assess the nerve impairment. For this reason, an attempt was made to use an Electric Pulp Tester to assess inferior alveolar nerve block anesthesia. Materials and Methods: Thirty patients were tested. Electric pulp testing of the lower jaw skin was performed at the three different times, before anesthesia, at the onset of sensory changes and after 15 minutes waiting from the onset, and on the 10 points of the chin, which produced 10 sections on the skin area. Results: Twenty seven patients (90%) could feel the electric stimulus on the chin at all 10 points before local anesthesia and the scores represent the statistical differences between the right and left points except R4 and L4. After anesthesia, the difference between the right and left points (L3-R3, L4-R4, L5-R5) increased significantly with time but two points (L2, R2) showed no significant difference. The scores on the left chin (L3, L4, L5) increased, whereas the other points (R1-R5, L1, L2) showed no significant differences. Conclusion: This study highlights the potential clinical use of an electric pulp tester for an assessment of inferior alveolar nerve impairment.

Effects of Virtual Reality Images on Body Stability : Focused on Hand Stability (VR 영상이 신체 안정성에 미치는 영향 : 손 안정성을 중심으로)

  • Han, Seung Jo;Kim, Sun-Uk;Koo, Kyo-Chan;Lee, Kyun-Joo;Cho, Min-Su
    • Journal of Digital Convergence
    • /
    • v.15 no.8
    • /
    • pp.391-400
    • /
    • 2017
  • The purpose of this paper is to present the effect of image stimulation on body stability as a conceptual model and to investigate the effect of image stimulus(2D, VR) on body stability(hand stability) through experiments Recently, stereoscopic images such as virtual and augmented reality are combined with smart phones and exercise equipments, and the diffusion is becoming active. The possibility of a safety accident or human error is also increasing as it temporarily affects the balance of the body and hand stability after the image stimulus is removed. The conceptual model is presented based on the results of previous studies. Based on the experimental results, the conceptual model has been explained in combination with the human information processing process and cognitive resource models that take place in the brain. Twenty subjects were exposed to 2D and VR stimuli, and display fatigue was measured by cybersickness questionnaire and hand stability by hand steadiness tester. Experimental results show that VR images induce higher display fatigue and lower hand stability than 2D. In this study, it is meaningful that hand stability according to image type and display fatigue level which have not been tried yet is revealed through conceptual model and experiment.

Effect of Vibrational Amplitude on Friction and Wear Properties of Magnetorheological Elastomer (진폭에 따른 자기유변탄성체의 마찰 특성 연구)

  • Lian, Chenglong;Lee, Kwang-Hee;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • Magnetorheological elastomers (MREs) are a type of “smart” material, and their properties can be controlled rapidly and reversibly under the influence of an external stimulus. The application of an external magnetic field can change the shear modulus, hardness, and friction coefficient of MREs. The friction can cause vibration; moreover, the vibration can affect friction. The change of friction depends on the relative motion, normal force, roughness of the rubbing surfaces, material type, temperature, lubrication, relative humidity, and vibration condition. As MREs are a type of “smart material,” their friction coefficient can be reduced by applying an external magnetic field—the applications of this feature in engineering have been widely studied. However, the friction properties of MREs under vibration have not been tested to date. In this study, MRE samples and a reciprocating friction tester were fabricated. The friction coefficient was measured to evaluate the friction properties under various vibration conditions; subsequently, the wear depth and wear surface profile of the MRE were observed in order to evaluate the wear properties. The results show that the friction coefficient of the MREs decreased when a magnetic field was applied. Moreover, the friction coefficient decreased when the vibrational amplitudes increased. The wear depth of the MRE also decreased as the vibrational amplitudes increased.

Desensitizing Effects of a Nd:YAG Laser Irradiation on Hypersensitive Dentine (지각과민치아에 대한 Nd:YAG 레이저 조사의 효과)

  • Jung, Sung-Yong;Kim, Kyoung-Hee;Ko, Myong-Yun;Ahn, Yong-Woo;Park, Jun-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.465-473
    • /
    • 2005
  • The purpose of this study was to evaluate the desensitizing effects of a Nd:YAG laser (Sunlase, SUNRISE Technologies, Inc., USA) irradiation on cervically exposed hypersensitive dentine. 45 patients was irradiated with pulsed Nd:YAG laser (1.5 W, 20 Hz, 75 mJ/pulse, 4 minutes) as the experimental group, 27 patients was mock irradiated as the control group. The degree of sensitivity to the thermal and tactile stimuli were determined qualitatively with an evaporative stimulus defined as two times air blast at a distance of 3 mm from each site to be tested and with a mechanical stimulus as a slightly scratching the cervical site with a dental explorer. A qualitative registration of the degree of discomfort was determined according to a numerical pain scale(NPS) in an 11-point scale in which 0= "no pain" and 10="most excruciating pain imaginable". Recordings were assessed before treatment, immediately after, 1 and 2 weeks after treatment. Pain tolerance threshold and pulp vitality were evaluated with electric pulp tester before and immediately after treatment. 1. Desensitizing of hypersensitive dentine with Nd:YAG laser irradiation was more effective than that with mock irradiation. 2. The placebo effect of mock irradiation was recognized for severe sensitive teeth($NPS\;{\geqq}\;6$), but not for moderate sensitive teeth(NPS < 6). 3. Laser irradiation did not affect the pain tolerance threshold and pulp vitality of the hypersensitive teeth. 4. Desensitizing effect of laser irradiation for the hypersensitive teeth had been continuing at least 2 weeks. It was concluded that desensitizing of hypersensitive dentine with a Nd:YAG laser is effective and the maintenance of the positive result was more prolonged than the placebo effect.