• Title/Summary/Keyword: Stiffness Reinforcement

Search Result 574, Processing Time 0.02 seconds

Experimental study of structural behavior of 80MPa concrete outrigger member using post tension method (PT공법을 적용한 80MPa급 콘크리트 아웃리거부재의 실험적 연구)

  • Choi, Jong-Moon;Kim, Woo-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.31-34
    • /
    • 2009
  • Large outrigger elements tie the concrete core to perimeter columns, significantly increasing the building's lateral stiffness as well as its resistance to overturning due to wind. The outriggers are deep elements, and large tie forces are resisted by top and bottom heavy longitudinal reinforcing and vertical ties. To reduce construction costs, all primary reinforcing bars in outrigger levels are SD500. Further, concrete strengths of 80MPa have been specified for outrigger elements. However, the reductions in the amount of concrete and reinforcement steel are more increased in tall building. With these backgrounds, 80MPa high strength concrete outrigger system using post tension method is developed. Significant economic savings can be made by reducing the element sizes and material content. The developed outrigger system is designed using strut-and-tie models. In addition, four 1/4-scale test specimens were selected from the same prototype structure. The results from the tests are confirmed that the structural behaviors of the developed outrigger member have better capacities than those of a conventional method.

  • PDF

An Experimental Study on the Shear Connection of Inverted T-shape Composite Beam Encased Web (역T형강 합성보의 전단연결에 관한 실험적 연구)

  • Jeong, Jae-Hun;Kim, Jin-Mu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.131-138
    • /
    • 2001
  • In inverted T-shape composite beam examine the structural behavior by experiment According to arrangement, type of stud connector, type of shear connector, reinforcement by welding of stirrup and a close analysis we came to these conclusion. 1) The compare result of bending strength according to arrange type of stud connector : A1-W(stud connector located web)specimen is exceed than A1-F(stud connector located flange). 2) B1-N(using prominence and depression of the web by shear connector) specimen is decrease than A1-W(using stud bolt by shear connector)specimen in bending strength and B2-N(reinforced by welding the stirrup to lower flange)specimen is similar with A2-W specimen. 3) According to reinforced by welding the stirrup to flange, the stiffness and bending strength of the beams are increase. A-scries stirrup comparatively low effective in the increase of strength by welding the stirrup to flange because enough composite effect show by stud connector, but B-series stirrup is comparatively high effective in shear connector effect because shortage of prominence and depression of the web.

  • PDF

A Study on CFRTP Aircraft Frame Stiffening by OOA Process (OOA 공정을 통한 CFRTP 항공기 Frame 보강재 성형에 관한 연구)

  • Lee, Hwan-Ju;Jeon, Yong-Jun;Choi, Hyun-Seok;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.15-19
    • /
    • 2017
  • Carbon fiber reinforced plastic (CFRP) is applied as structural material. CFRP is excellent in plane strength / stiffness and don't haves rust. Lightweight, rigid and robust at the same time as transportation material. Aluminum alloy and reinforcement material The application is increasing rapidly. In this study, the prototype of a semi - Monocoque structure frame, Longeron, Stringer, Skin of the aircraft, restraining the rigidity Clips of the aircraft was designated as the target product and the experiment was conducted. ln the experiment, (1) For CFRTP 3 points, data on heating, transfer, and cooling were measured using Thermo Couple, and optimum temperature required for flexible state was obtained. Heating was performed at a temperature 15% higher than the provided temperature. (2) By using a pneumatic press during molding, by dividing LH, center and RH according to the cooling time, thickness parameter of the target product due to the load is measured, and thickness control and time-deviations were analyzed and cross sections were observed with a low magnification microscope.

A Study on the Clamping Force Estimation and Failsafe Control Algorithm Design of the Electronic Wedge Brake System (Electronic Wedge Brake 시스템의 클램핑력 추정 및 Failsafe 제어 알고리즘 설계에 관한 연구)

  • Chung, Seunghwan;Lee, Hyeongcheol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.16-23
    • /
    • 2016
  • The EWB(electronic wedge brake) is one in which the braking force is developed in a wedge and caliper system and applied to a disk and wedge mechanism. The advantage of the wedge structure is that it produces self-reinforcing effect and hence, utilizes minimal motor power, resulting in reduced gear and current. The extent of use of clamping force sensors and protection from failure of the EWB system directly depends on the level of vehicle mass production. This study investigated the mathematical equations, simulation modeling, and failsafe control algorithm for the clamping force sensor of the EWB and validated the simulations. As this EWB system modeling can be applied to motor inductance, resistance, screw inertia, stiffness, and wedge mass and angle, this study could improve the accuracy of simulation of the EWB. The simulation results demonstrated the braking force, motor speed, and current of the EWB system when the driver desired to the step and pulse the brake force inputs. Moreover, this paper demonstrated that the proposed failsafe control algorithm accurately detects faults in the clamping force sensor, if any.

Study on the Bending Test of Glulam Beam Reinforced with GFRP Strips (복합재료로 보강된 집성보의 휨 실험에 대한 연구)

  • Kim, Young-Chan;Davalos, Julio F.
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.199-204
    • /
    • 1999
  • A recent application of advanced composite materials, primarily fiber-reinforced plastic (FRP) composites, in structures is the reinforcement of conventional structural materials, such as concrete and glued-laminated timber (glulam), to increase their performance. In particular, the construction of large-scale glulam structures usually requires members with large depths and to significantly increase the stiffness and strength of glulam, the members can be reinforced with FRP at top and bottom surfaces. In this paper, glulam beams reinforced with GFRP strip are tested under 2-point bending and results are compared with numerical solution using layer-wise beam theory.

  • PDF

Lateral Load Test for Various Aseismatic Methods of Pile Heads of Pier Type Quay Walls (잔교식 안벽의 말뚝 두부 내진 보강기법에 따른 수평재하실험)

  • 이용재;한진태;장인성;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.98-106
    • /
    • 2003
  • To construct pile-supported wharf structures that must support heavy horizontal loads, both vertical piles and batter piles are used. Batter piles are used to secure the bearing capacity against the horizontal loads. However, past case histories have shown that the heads of batter piles are vulnerable because these heads are subjected to excessive axial loads during earthquakes. Therefore, the aseismatic reinforcement method must be developed to prevent batter pile heads from breaking due to excessive seismic loads. Two different connecting methods of either inserting rubber or ball-bearing between batter pile head and upper plate were proposed to improve the aseismatic efficiency. Three large-scale pile head models(rubber type model, ball-bearing type model, and fixed type model) were manufactured and horizontal loading tests were peformed for these models. The results showed that the force-displacement relationship of the fixed type model was linear, but that of the rubber type model and the ball-bearing type model was bilinear. The increase in the horizontal displacement led to the increase in the horizontal stiffness of the rubber type models and the decrease in that of the ball-bearing type model. Compared with the values for fixed type model, the damping ratios of the rubber type model and the ball-bearing type model increased about 33~185% and 263~269%, respectively.

  • PDF

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • This paper experimentally studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Four beam-to-wall connection specimens with short and long embedded steel columns are tested under monotonic and cyclic loads, respectively. The influence of embedment length of columns on the failure mode and performance of connections is investigated. The results show that the length of embedded steel columns has significant effect on the failure mode of connections. A connection with a long embedded column has a better stiffness, load-bearing capacity and ductility than that of a short embedded column. The former fails due to the shear yielding of column web in the joint panel, while failure of the latter is initiated by the yielding of horizontal reinforcement in the wall due to the rigid rotation of the column. It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility.

Cyclic performance of RC beam-column joints enhanced with superelastic SMA rebars

  • Ghasemitabar, Amirhosein;Rahmdel, Javad Mokari;Shafei, Erfan
    • Computers and Concrete
    • /
    • v.25 no.4
    • /
    • pp.293-302
    • /
    • 2020
  • Connections play a significant role in strength of structures against earthquake-induced loads. According to the post-seismic reports, connection failure is a cause of overall failure in reinforced concrete (RC) structures. Connection failure results in a sudden increase in inter-story drift, followed by early and progressive failure across the entire structure. This article investigated the cyclic performance and behavioral improvement of shape-memory alloy-based connections (SMA-based connections). The novelty of the present work is focused on the effect of shape memory alloy bars is damage reduction, strain recoverability, and cracking distribution of the stated material in RC moment frames under seismic loads using 3D nonlinear static analyses. The present numerical study was verified using two experimental connections. Then, the performance of connections was studied using 14 models with different reinforcement details on a scale of 3:4. The response parameters under study included moment-rotation, secant stiffness, energy dissipation, strain of bar, and moment-curvature of the connection. The connections were simulated using LS-DYNA environment. The models with longitudinal SMA-based bars, as the main bars, could eliminate residual plastic rotations and thus reduce the demand for post-earthquake structural repairs. The flag-shaped stress-strain curve of SMA-based materials resulted in a very slight residual drift in such connections.

Flexural behaviour of steel beams reinforced by carbon fibre reinforced polymer: Experimental and numerical study

  • Tahar, Hassaine Daouadji;Boussad, Abbes;Abderezak, Rabahi;Rabia, Benferhat;Fazilay, Abbes;Belkacem, Adim
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.409-420
    • /
    • 2019
  • The paper presents the results of an experimental and numerical programme to characterize the behaviour of steel beams reinforcement by composite plates. Important failure mode of such plated beams is the debonding of the composite plates from the steel beam due to high level of stress concentration in the adhesive at the ends of the composite plate. In this new research, an experimental and numerical finite element study is presented to calculate the stresses in the sika carbodur and sika wrap reinforced steel beam under mechanical loading. The main objective of the experimental program was the evaluation of the force transfer mechanism, the increase of the load capacity of the steel beam and the flexural stiffness. It also validated different analytical and numerical models for the analysis of sika carbodur and sika wrap reinforced steel beams. In particular, a finite element model validated with respect to the experimental data and in relation to the analytical approach is presented. Experimental and numerical results from the present analysis are presented in order to show the advantages of the present solution over existing ones and to reconcile debonding stresses with strengthening quality.

Implementation of bond-slip effects on behaviour of slabs in structures

  • Mousavi, S.S.;Dehestani, M.
    • Computers and Concrete
    • /
    • v.16 no.2
    • /
    • pp.311-327
    • /
    • 2015
  • Employing discrete elements for considering bond-slip effects in reinforced concrete structures is very time consuming. In this study, a new modified embedded element method is used to consider the bond-slip phenomenon in structural behavior of reinforced concrete structures. A comprehensive parametric study of RC slabs is performed to determine influence of different variables on structural behavior. The parametric study includes a set of simple models accompanied with complex models such as multi-storey buildings. The procedure includes the decrease in the effective stiffness of steel bar in the layered model. Validation of the proposed model with existing experimental results demonstrates that the model is capable of considering the bond-slip effects in embedded elements. Results demonstrate the significant effect of bond-slip on total behavior of structural members. Concrete characteristic strengths, steel yield stress, bar diameter, concrete coverage and reinforcement ratios are the parameters considered in the parametric study. Results revealed that the overall behavior of slab is significantly affected by bar diameter compared with other parameters. Variation of steel yield stress has insignificant impact in static response of RC slabs; however, its effect in cyclic behavior is important.