• Title/Summary/Keyword: Stereotactic target

Search Result 145, Processing Time 0.117 seconds

Stereotactic body radiation therapy for liver oligo-recurrence and oligo-progression from various tumors

  • Cha, Yu Jin;Kim, Mi-Sook;Jang, Won-Il;Seo, Young Seok;Cho, Chul Koo;Yoo, Hyung Jun;Paik, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.172-179
    • /
    • 2017
  • Purpose: To evaluate the outcomes of stereotactic body radiation therapy (SBRT) for patients with liver oligo-recurrence and oligo-progression from various primary tumors. Materials and Methods: Between 2002 and 2013, 72 patients with liver oligo-recurrence (oligo-metastasis with a controlled primary tumor) and oligo-progression (contradictory progression of a few sites of disease despite an overall tumor burden response to therapy) underwent SBRT. Of these, 9 and 8 patients with uncontrollable distant metastases and patients immediate loss to follow-up, respectively, were excluded. The total planning target volume was used to select the SBRT dose (median, 48 Gy; range, 30 to 60 Gy, 3-4 fractions). Toxicity was evaluated using the Common Toxicity Criteria for Adverse Events v4.0. Results: We evaluated 55 patients (77 lesions) treated with SBRT for liver metastases. All patients had controlled primary lesions, and 28 patients had stable lesions at another site (oligo-progression). The most common primary site was the colon (36 patients), followed by the stomach (6 patients) and other sites (13 patients). The 2-year local control and progression-free survival rates were 68% and 22%, respectively. The 2- and 5-year overall survival rates were 56% and 20%, respectively. The most common adverse events were grade 1-2 fatigue, nausea, and vomiting; no grade ${\geq}3$ toxicities were observed. Univariate analysis revealed that oligo-progression associated with poor survival. Conclusion: SBRT for liver oligo-recurrence and oligo-progression appears safe, with similar local control rates. For liver oligo-progression, criteria are needed to select patients in whom improved overall survival can be expected through SBRT.

Development of 3-D Radiosurgery Planning System Using IBM Personal Computer (IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발)

  • Suh Tae-Suk;Suh Doug-Young;Park Charn Il;Ha Sung Whan;Kang Wee Saing;Park Sung Hun;Yoon Sei Chul
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF

The Effectiveness of Volumetric Modulated arc Radiotherapy to Treat Patients with Metastatic Spinal Tumors

  • Park, Hyo-Kuk;Kim, Sungchul
    • International Journal of Contents
    • /
    • v.13 no.4
    • /
    • pp.12-15
    • /
    • 2017
  • Among the possible stereotactic body radiation therapy (SBRT) modalities used to treat patients with metastatic spinal tumors, this study compared Cyberknife, tomotherapy, and volumetric modulated arc radiotherapy (VMAT). We established treatment plans for each of them modality and quantitatively analyzed the dose evaluation factors of the dose-volume histogram (DVH) for all spinal bones, focusing on the tumor and spinal cord, in order to examine the usefulness of VMAT. For the treatment planning dose, the mean dose ($D_{max}$) and $D_{5%}$ showed statistical differences in the target dose, but no difference was shown in the spinal cord dose. For the DVH indices, tomotherapy showed the best performance was the best in terms of uniformity index, while VMAT showed better performance was better than the other two modalities in terms of the conformity index and the dose gradient index. VMAT had a much shorter treatment time than Cyberknife and tomotherapy. These findings suggest that VMAT FFF is the most effective therapy for SBRT of patients with metastatic spinal tumors for whom a high dose of radiation is prescribed.

Fractionated Stereotactic Radiotherapy in Pediatric Diffuse Intrinsic Brain Stem Gliomas

  • Choi, Woo-Jin;Yee, Gi-Taek;Han, Seong-Rok;Yoon, Sang-Won;Lee, Dong-Joon;Whang, Choong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.154-158
    • /
    • 2006
  • Objective : We treated 10 pediatric diffuse intrinsic brain stem glioma[BSG] patients with Novalis system [linac based radiotherapy unit, Germany] and examined the efficacy of the Fractionated Stereotactic Radiotherapy[FSRT]. Methods : A retrospective review was conducted on 10 pediatric diffuse intrinsic BSG patients who were treated with FSRT between May, 2001 and August, 2004. The mean age of the patient group was 7.7 years old. Male to female ratio was 4 to 1. The mean dose of FSRT was 38.7Gy, mean fractionated dose was 2.6Gy, mean fractionation size was 16.6, and target volume was $42.78cm^3$. The mean follow up period was 14 months. Results : Four weeks after completion of FSRT, improvements on neurological status and Karnofsky performance scale[KPS] score were recorded in 9/10 (90%] patients and magnetic resonance imaging[MRI] showed decrease in target tumor volume in 8 pediatric patients. The median survival period was 13.5 months after FSRT and treatment toxicity was mild. Conclusion : It is difficult for surgeons to choose surgical treatment for diffuse intrinsic BSG due to its dangerous anatomical structures. FSRT made it possible to control the tumor volume to improve neurological symptoms with minimal complications. We expect that FSRT is a feasible treatment modality for pediatric diffuse intrinsic BSG with tolerable toxicities.

Optimization Technique using Ideal Target Model and Database in SRS

  • Oh, Seung-Jong;Suh, Tae-Suk;Song, Ju-Young;Choe, Bo-Young;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.146-149
    • /
    • 2002
  • The aim of stereotactic radiosurgery(SRS) is to deliver a high dose to a target region and a low dose to critical organ through only one or a few irradiation. To satisfy this aim, optimized irradiating conditions must be searched in the planning. Thus, many mathematical methods such as gradient method, simulated annealing and genetic algorithm had been proposed to find out the conditions automatically. There were some limitations using these methods: the long calculation time, and the difficulty of unique solution due to the different shape of tumor. In this study, optimization protocol using ideal models and data base was proposed. Proposed optimization protocol constitutes two steps. First step was a preliminary work. Some possible ideal geometry shapes, such as sphere, cylinder, cone shape or the combination, were assumed to approximate the real tumor shapes. Optimum variables such as isocenter position or collimator size, were determined so that the high dose region could be shaped to fit ideal models with the arrangement of multiple isocenter. Data base were formed with those results. Second, any shaped real targets were approximated to these models using geometry comparison. Then, optimum variables for ideal geometry were chosen from the data base predetermined, and final parameters were obtained by adjusting these data. Although the results of applying the data base to patients were not superior to the result of optimization in each case, it can be acceptable as a starting point of plan.

  • PDF

Simulation Study for the Distortion Correction of Digital Angiographic Images using Geometric Transformation (디지털 혈관 조영상의 기하학적 왜곡 보정을 위한 모의 실험 연구)

  • 진호상;신동훈;허순녕;곽철은;최보영;이형구;서태석
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.365-373
    • /
    • 2002
  • Accurate localization of target lesion is required to protect normal peripheral tissue and irradiate exactly to tumors in stereotactic radiosurgery(SRS). Digital angiography is one of the most effective diagnostic tools to detect and identify the target tumors. However, it shows pincushion distortion due to the characteristics of the image intensifier. We have implemented a simulation study for the correction of distortion using the geometric transformation. Phantom images were produced transformation. In conclusion, the geometric transformation could effectively be used for the pincushion distortion of image intensifier and there was no significant different between two methods indicating 2% correction error from the ideal image in all cases.

Stereotactic Radiosurgery for Dural Arteriovenous Fistulas Involving the Transverse-Sigmoid Sinus : A Single Center Experience and Review of the Literatures

  • Baek, Hong-Gyu;Park, Seong-Hyun;Park, Ki-Su;Kang, Dong-Hun;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.458-466
    • /
    • 2019
  • Objective : We retrospectively assessed the efficacy of stereotactic radiosurgery (SRS) for dural arteriovenous fistulas (DAVFs) involving the transverse-sigmoid sinus and analyzed the angiographic and clinical results with our 8-year experience. Methods : Nine patients with intracranial DAVFs involving the transverse-sigmoid sinus underwent SRS using a Gamma $Knife^{(R)}$ (Elekta Inc., Atlanta, GA, USA) between 2009 and 2016. Five patients underwent SRS for residual DAVFs after embolization and four patients were treated with SRS alone. The median target volume was $1.9cm^3$ (range, 0.8-14.2) and the median radiation dose of the target was 17 Gy (range, 16-20). The median follow-up period was 37 months (range, 7-81). Results : Pulsating tinnitus (33%) was the most common symptom. DAVFs were completely obliterated in four patients (44%) and subtotally obliterated in five (56%). Six patients (67%) showed complete recovery of symptoms or signs, and three (33%) showed incomplete recovery. One patient experienced a recurrent seizure. Adverse radiation effects after SRS occurred in one patient (11%). The total obliteration rates after SRS were 16.7%, 37.5%, and 68.7% at 1, 2, and 3 years, respectively. The median interval from SRS to total obliteration of the fistula was 31 months (range, 12-38). The rates at which the symptoms started to improve were 40% at 1 month and 80% at 2 months after SRS. Symptoms started to improve at a median of 5 weeks after SRS (range, 3-21). Conclusion : SRS with or without embolization is a safe and effective treatment to relieve symptoms and obliterate DAVFs on the transverse-sigmoid sinus.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF