The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.
The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.
뇌 신경계에 발생한 비정상조직 등 병소들을 수술적 방법으로 생체 조직검사 시 방사선 영상 공간과 실제 물리적 공간을 3 차원적으로 일치시키고 국재(localization)하는 영상지원 뇌 정위 수술은 혹시 발생할지도 모르는 후유증을 최소화할 수 있다. 본 연구는 대부분 고가의 대형 정위 수술 프로그램에 포함되어 있는 뇌수술을 영상 지원하는 정위적 국재 프로그램들 중 임상에서 수술 빈도가 높은 생체조직 검사 시술 시에 최소한의 기능으로 수술을 지원할 수 있는 프로그램을 개발하고 팬텀을 이용해 국재 정확도를 측정한 후 임상에서 사용 가능성을 평가하였다. 프로그램은 영상자료 입력, fiducial marker 등록, 목표점 좌표 지정 및 좌표 값 표시 등 3 부분으로 구성하였고 팬텀을 이용한 프로그램의 정확도를 측정결과 임상에서 요구되는 일반적인 국재 정확도 한계인 2 mm 이내였다. 이 프로그램은 고난도의 뇌 정위 생검 수술시 정확한 시술이 가능하도록 지원하여 수술의 위험도를 줄이고 수술 성공률 향상에 기여할 수 있으리라 생각된다.
정위적 방사선 수술과 신경외과적 수술분야 에서는 상호보완적인 영상정보를 얻기 위하여 컴퓨터 단층촬영 (CT), 자기공명영상 (MRI) 그리고 혈관조영촬영이 사용된다. 본 연구의 목적은 여러 영상장치와 다목적 QA(Quality Control) 팬톰을 이용하면서, 정위적 방사선수술 및 신경외과적 수술분 야에서 두경부내의 병소에 대한 모양, 크기, 위치를 정확하게 결정하기 위한 3 차원 정위 시스템을 개발하는 것이다. 목표물의 정확한 위치를 정의하기 위하여, Hitchcoke 정위 프레임과 컴퓨터 단층 촬영 (CT)/혈관 조영촬영용 위치측정 보조기구들을 3차원 공간상에 9개의 목표물을 가진 팬톰에 고정하였다. 컴퓨터 단층촬영과 혈관 조영촬영을 이용하여 얻은 기하학적 팬톰의 영상들을 이용하여, 목표물의 3차원 정위좌표를 얻기위한 알고리즘이 개발되었다. 개발된 알고리즘에 의해 계산된 목표물들의 위치는 팬톰의 절대 좌표와 비교 되었고, 각 CT 영상에서의 목표물들은 뇌혈관촬영 영상위에 상호 중첩될 수 있도록 개발 되었다. 512$\times$512 메트릭스와 2mm 슬라이스 두께를 가진 컴퓨터 단층촬영에 있어서는 1.02$\pm$0.17 mm의 평균거리오차를 보였고, 혈관 조영촬영인 경우에는 0.41$\pm$0.05mm 의 평균거리오차를 보였다. 목표물의 위치를 결정하는데 있어서 결과로 나온 정확도는 개발된 시스템이 정위적 방사선수술과 신경외과적수술을 위해 충분히 신뢰성이 있음을 확인해주었다.
Objectives: The purpose of this study is to evaluate the safety and effectiveness of Robot-Assisted Brain Stereotactic Surgery with a systematic review. Methods: Electronic literature was searched using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library on 6th April 2017. Two authors screened 1218 citations. Duplicated articles of 456 excluded, the remaining 762 articles were reviewed with title and abstract. Results: A total of 8 studies were selected in this review. The device used in all studies was $ROSA^{TM}$. In one cohort study comparing the intervention ($ROSA^{TM}$) with the control (conventional stereotactic surgery), hematoma was reported no significant difference between groups. In six descriptive studies, one study reported hematoma 10% (10/100) and temporary nerve impairment 6% (6/100) using the ROSA; while five descriptive study did not report any complications. In one cohort, the localization precision were 1.2 mm in the intervention group and 1.1 mm in the control group; the localization success rate as 78.2% in the intervention group and 76.2% in the control group in one cohort; and the average time for surgery as 130 min for the intervention group and 352 min for the control group in one cohort. Four studies reported the localization success rate as 100%; two out of three articles reported the overall time for surgery as 56 min and 90 min, while one article reported the time as less than one hour in 50% of patients (50/100); two articles reported in epilepsy patients, the condition after the surgery was Engel level I in 66.2%, 75% patients, Engel level II-III in 25%, 26.5% patients, and Engel level 4 in 7.3% patients. Conclusion: Robot-Assisted Brain Stereotactic Surgery is a safe and accurate technique that can significantly reduce the time for the brain stereotactic surgery. However, further studies are needed to generalize the results.
Stereotactic body radiation therapy (SBRT) appears an effective and safe treatment modality for spinal bone metastasis, which can enhance local control and improve quality of life. Life expectation, predicted fracture risk, localization, quality, size and number of metastasis and presence or absence of nerve compression seem to be important factors in decision-making for treatment. Further studies are needed to identify subsets of patient which will most benefit from treatment.
유방촬영술을 이용한 유방암 검진은 표준 영상 방법이다. 초음파에서 보이지 않고 유방촬영술이나 디지털 유방 토모신테시스에서만 보이는 의심스러운 석회화, 구조 왜곡의 조직학적 진단을 위해 입체정위생검과 유방촬영술 유도하 수술 전 위치결정술을 시행한다. 본 종설에서는 입체정위생검의 적응증 및 비적응증, 방법, 입체정위생검 후 클립 삽입과 디지털 유방 토모신테시스 유도하 입체정위생검에 대해 알아보고자 한다. 또한, 유방촬영술 유도하 수술 전 위치결정술을 침위치결정술과 비침위치결정술로 나누어 소개하고자 한다.
정위적 방사선수술 (Stereotactic radiosurgery) 은 병소(region)의 위치를 정확히 결정하고 치료에 요구되는 방사선량이 정확히 전달되는 것이 중요하다. 본 연구는 이를 실험적으로 확인할 목적으로 특별히 고안된 물팬텀 (water phantom)을 개발하여 Leksell 정위기구 (Leksell Stereotactic Frame; LSF)에 부착하여 방사선수술을 시행하였다. 방사선 수술에는 Leksell 감마나이프 (Gamma Knife Unit; GKU) 와 LSF를 사용하였으며 실험을 위해 개발된 팬텀은 1mm 두께 플라스틱의 직경 160mm의 구형으로 물을 채울수 있는 구조로 되어있다. 측정장치로서는 목표점 설정(target localization)을 위한 필름과 전달 선량(dose delivery) 측정을 위해 이온 전리함(ionchamber) 을 사용하였으며 이를 팬텀의 목표점에 각각 위치시킬 수 있도록 설계하였다. 본 연구에서 목표점 확인은 허용 오차범위인 $\pm$0.5 mm 이내에서의 값을 보였으며 선량전달값은 $\pm$3% 정도의 오차로 허용값내에 있음을 보여주었다. 본 연구에서 개발된 팬텀으로 측정된 값이 모두 허용 오차범위 내에 있음을 보여주었고 이로인해 GKU 및 LSF의 주기적 QA(Quality Assurance)에 계속적으로 사용할수 있게 되었다.
The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.