• 제목/요약/키워드: Step by step

검색결과 16,074건 처리시간 0.042초

단계적 측정법에 의한 시간 영역 음향 홀로그래피 (Time Domain Acoustic Holography by Step-by-step Measurement)

  • 윤호성;남경욱;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.635-639
    • /
    • 2003
  • When we carry out acoustic holography, step-by-step measurement provides us larger aperture size with same number of microphones. But when we carry out step-by-step measurement, it is blown that sound signal must be stationary. However, when transfer function between input and output signal is time-invariant, we can apply step-by-step measurement to acoustic holography even if sound signal is transient We have to do only some Processing on signals from step-by-step measurements to make the signal data of each step compatiable with other steps. This paper accounts for that processing method.

  • PDF

지리산 주변 산지하천의 step-pool 구조 특성 (Characteristics of step-pool structure in the mountain streams around Mt. Jiri)

  • 김기흥;정혜련
    • 한국수자원학회논문집
    • /
    • 제51권4호
    • /
    • pp.313-322
    • /
    • 2018
  • Step의 높이는 하상재료 입경의 크기와 거의 같은 상관관계가 있으며, 하도경사에 따라 증가하고, 하도 폭과 step 파장은 거의 같은 크기로서 하도경사가 증가하면 step 파장은 감소하는 것으로 분석되었다. 하도 폭과 step 폭은 뚜렷한 상관관계가 있으며, 하도 폭의 증가에 따라 step 폭도 증가하는 것으로 분석되었다. 또한, step 파장은 하도 폭에 의하여 규모가 정해지고, step 높이는 step을 형성하는 암석의 크기에 의해 지배되기 때문에 step-pool의 종단면의 하상구조는 하도경사에 따라 변화하는 것으로 판단된다. Pool의 규모는 하도 폭, 입경 및 하도경사와 상관성이 큰 것을 확인하였다. 따라서 하천의 step-pool 구조 특성은 다양한 인자들의 영향을 받지만 대표적으로 입경, 하도 폭 및 하도경사로서 설명할 수 있는 것으로 분석되었다.

적응시간 간격 알고리즘을 이용한 KIM의 계산 효율성 개선 (The Improvement of Computational Efficiency in KIM by an Adaptive Time-step Algorithm)

  • 남현;최석진
    • 대기
    • /
    • 제33권4호
    • /
    • pp.331-341
    • /
    • 2023
  • A numerical forecasting models usually predict future states by performing time integration considering fixed static time-steps. A time-step that is too long can cause model instability and failure of forecast simulation, and a time-step that is too short can cause unnecessary time integration calculations. Thus, in numerical models, the time-step size can be determined by the CFL (Courant-Friedrichs-Lewy)-condition, and this condition acts as a necessary condition for finding a numerical solution. A static time-step is defined as using the same fixed time-step for time integration. On the other hand, applying a different time-step for each integration while guaranteeing the stability of the solution in time advancement is called an adaptive time-step. The adaptive time-step algorithm is a method of presenting the maximum usable time-step suitable for each integration based on the CFL-condition for the adaptive time-step. In this paper, the adaptive time-step algorithm is applied for the Korean Integrated Model (KIM) to determine suitable parameters used for the adaptive time-step algorithm through the monthly verifications of 10-day simulations (during January and July 2017) at about 12 km resolution. By comparing the numerical results obtained by applying the 25 second static time-step to KIM in Supercomputer 5 (Nurion), it shows similar results in terms of forecast quality, presents the maximum available time-step for each integration, and improves the calculation efficiency by reducing the number of total time integrations by 19%.

Balanced Force와 Step-Back 근관성형후 치근단 폐쇄효과의 비교연구 (A COMPARISON OF APICAL SEAL FOLLOWING "STEP-DOWN/BALANCED FORCE" AND "STEP-DOWN/STEP-BACK" ROOT CANAL SHAPING)

  • 이윤희;김종화;손호현;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.780-788
    • /
    • 1995
  • The purpose of this study was to compare the apical seal following root canal shaping by different methods. From fourty extracted mandibular 1st and 2nd molars, fourty mesial roots whose canals have some degree of curvature were selected. The mesiobuccal root portion including mesiobuccal portion of a crown was sectioned in each molar. After access cavity preparation for the mesiobuccal canal, working length was determined with # 10 K-file. The sectioned roots were implanted in acrylic resin block and randomly divided into four groups. The canals of group I were shaped by step-down/balanced force, group II by stepdown/step-back, group III by step-back and group IV by conventional method. All of the shaped canals were obturated by Thermafil method and access cavities were filled with IRM. The roots were removed from acrylic resin block and placed in 100 % humidity for 7days. Except the root surfaces of apical 2mm, the root surfaces were nail-varnished 3 times. After the roots were placed in 700 torr vacuum pressure for 15 minutes, they were immersed in 2% methylene blue solution for 4 days. Nail varnishes were removed with acetone. After that, the roots were decalcified in 5 % nitric acid and dehydrated with alcohol series. Transparent specimens were made by methyl salicylate and the quality of apical seal was assessed by measuring the leakage linearly. The results were as follows. 1. The leakage in canals shaped by step-down/balanced force method was significantly less than that in canals shaped by step-back method(P<0.05) and was less but not statistically than that in canals shaped by step-down/step-back method (P>0.05). 2. The leakage in canals shaped by step-down/step-back method was less than that in canals shaped by step-back method, but there was no statistical significance(P>0.05). 3. The leakage in canals shaped by conventional method was significantly more than that in canals shaped by step-down/balanced force, step-down/step-back and step-back method (P<0.05).

  • PDF

양호교사에 의한 학생(學生) 신체검사(身體檢査) 능력(能力)에 관한 평가(評價) (A Study on the analysis of physical assessment by school nurses)

  • 김화중
    • 한국학교보건학회지
    • /
    • 제1권1호
    • /
    • pp.148-159
    • /
    • 1988
  • For the evaluation of physical assessment by school nurses, this study was designed in two steps physical assessment. The first step is the primary health screening by school health nurses. The second step is the Physicians' physical examination of ill health students selected by school nurses. This study was conducted on a total of 3,525 students of three primary schools located in urban, township, and rural area during the period from May to June, 1987, all data were collected through direct observation & survey method. The main findings are as follows 1. The number of ill health students selected by two step method was more than that of one step method by the physician. 2. The types of ill health students selected by two step method had more diversity than that of one step method by the physician. 3. Budgets and time consumption for two step method were more reductive than that of one step method by the physician.

  • PDF

미세스텝 제어 방식에 의한 PM 스텝 모터의 위치 및 속도 제어에 관한 연구 (A Study on the Position and Speed Control of PM Step Motor Using Micro-Step Control Drive)

  • 김동현;한권상
    • 대한전자공학회논문지
    • /
    • 제27권6호
    • /
    • pp.871-878
    • /
    • 1990
  • The control method which electrically subdivides 1 step(1.8\ulcornerstep) of a PM step motor into 64 micro-step (0.028\ulcornerstep) is realized using micro-step algorithm on the basis of the look up table method and the position and velocity control using Z-80 microprocessor is also realized. With micro-stepping. The resolution of the system is improved, also by micro-step control of driving-current of the step motro, which is followed by the increase of micro-step subdivision-coefficient, the precise position and velocity control of step-motor can be realized and the stabilization of the system is improved.

  • PDF

Inverse Offset Method for Adaptive Cutter Path Generation from Point-based Surface

  • Kayal, Prasenjit
    • International Journal of CAD/CAM
    • /
    • 제7권1호
    • /
    • pp.21-30
    • /
    • 2007
  • The inverse offset method (IOM) is widely used for generating cutter paths from the point-based surface where the surface is characterised by a set of surface points rather than parametric polynomial surface equations. In the IOM, cutter path planning is carried out by specifying the grid sizes, called the step-forward and step-interval distances respectively in the forward and transverse cutting directions. The step-forward distance causes the chordal deviation and the step-forward distance produces the cusp. The chordal deviation and cusp are also functions of local surface slopes and curvatures. As the slopes and curvatures vary over the surface, different step-forward and step-interval distances are appropriate in different areas for obtaining the machined surface accurately and efficiently. In this paper, the chordal deviation and cusp height are calculated in consideration with the surface slopes and curvatures, and their combined effect is used to estimate the machined surface error. An adaptive grid generation algorithm is proposed, which enables the IOM to generate cutter paths adaptively using different step-forward and step-interval distances in different regions rather than constant step-forward and step-interval distances for entire surface.

기존 하수처리장에서의 처리 효율개선에 관한 연구 (A Study on the improvement of treatment efficiency in a conventional sewage treatment plant)

  • 안철우;박진식;문추연
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

STEP 데이터의 활용 방안에 대한 연구 (A Study on the Practical Usage of STEP data)

  • 예도경;박정선
    • 한국전자거래학회지
    • /
    • 제1권2호
    • /
    • pp.133-160
    • /
    • 1996
  • It is accomplished on the practical usage for STEP in enterprise. But they has feeble grasp of STEP, therfore it is hard to apply. That is due to take a negative policy with the lack of advertising and understanding, most of studies are going on a studentlike attitude rather than the practical usage or implementation, so they don't know exactly what is STEP, and how can they apply to their own enterprise. This paper aimed to present more detail understanding of STEP usage and practical usage of STEP data in enterprise. We describe EXPRESS that is description method of STEP, four ways of implementation method, and introduce to using ST-Developer and ST-Oracle by STEP Tools Inc. for more detail understand of STEP. Thereafter we propose practical usage of STEP with CAD systems and PDM systems on the knowledge of previous study, and propose total system implementation image on STEP data in enterprise, finally discuss conclusion and luther study issues.

  • PDF

STEP-Compliant CNC를 위한 STEP-NC Repository구축 (STEP-NC Repository for STEP-Compliant CNC)

  • 김준환;천상욱;한순흥
    • 한국CDE학회논문집
    • /
    • 제8권1호
    • /
    • pp.48-54
    • /
    • 2003
  • In a design-to-manufacturing environment, the product data is shared by various CAD/CAM/CAE systems with little integration or substantial data redundancy. The main purpose of this paper is to build a database containing all the features required for STEP-NC machining and to show how a STEP-NC repository can support the complete process for machining. A STEP-NC database schema has been constructed and several query functions have been built for the purpose of implementing the retrieving system of a STEP-NC database. The EXPRESS data model of ISO 14649 has been mapped to the database data definition language of the Oracle database. To apply the STEP-NC database to an industry example, the ISO 14649 part program has been stored into the STEP-NC database. To implement example scenarios, the sample query interface has been built.