• Title/Summary/Keyword: Step angle

Search Result 638, Processing Time 0.029 seconds

Development of Drill Geometry for Burr Minimization in Drilling (구멍가공시 버형성 최소화를 위한 드릴형상 개발)

  • 장재은;고성림
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.911-914
    • /
    • 1997
  • This Experiment was carried out for bur minimization in drilling. New drill geometries are proposed to minimize the burr formation in drilling operation. Three types of drills are made, champer, round and step drill. The burr formed in first cutting by front cutting edge ca be removed in second cutting by the cutting edges in chamfer, round edge and step. New burrs are formed by second cutting and can be minimized according to the change of drill geometry like, chamfer size and angle, corner radius in round drill and step size and angle in step drill. To measure the burr formed in drilling, laser sensor is used.

  • PDF

Analysis and Control of a 3-Phase VR Type Self-Bearing Step Motor for Small Angle Control Considered the fringing Effect (프린징효과를 고려한 미세각도 제어용 3상 가변형 셀프베어링 스텝모터의 해석 및 제어)

  • Kim, Daegon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.93-100
    • /
    • 2001
  • The analysis and control of a new type unsymmetrical slotted self-bearing step motor for small angle control is presented. The motor actuator is used for both motor and bearing functionality without any additional coil windings or electromagnets for bearing functionality. A circular-arc, straight-line permeance model for the fringing effect is presented. An unsymmetrical slotted self-bearing step motor layout and control algorithm are described. A new control current generation method using the electromagnets layout geometry, which needs no additional current for bearing functionality, is proposed. As the result of this analysis the fringing effect largely influences on the system characteristics. especially in torque. Even if the bearing functionality is added into the motor functionality, it is shown that the magnitude of torque is not changed.

  • PDF

Display station anthropometrics: Preferred height and angle settings of CRT and keyboard

  • Miller, Win;Suther Ill, Thomas-W.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.37-44
    • /
    • 1986
  • This study investigates display station physical adjustments preferred by a sample of visual display terminal operators. Participants in the study were selected to assure representation of extremely short and extremely tall persons, as well as persons of midrange physical stature. Individual operators were led through a step-by-step sequence to determine their preferred initial settings of seat height, keyboard height and slope angle, and CRT height and tilt angle. Each operator then performed a brief text input tase, after which final preferred adjustments were measured. Intermeasure correlation strongly suggest that "flat" (low slope angle) keyboards are in appropriate for short operators who select low seat heights. In addition, the keyboard angle adjustments preferred by most operators substantially exceed a current German ergonomic display station requirement.

  • PDF

A Simple Method for Conducting Angle Calculation of Switch Devices in Cascaded Inverters Using Step Pulse Waves (스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법)

  • Kim H.C.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.588-592
    • /
    • 2003
  • In recent years, the multilevel inverter synthesizing the output voltage with step pulse has been widely used as a solution for high power and high voltage applications. This paper proposes a simple method to obtain the conducting . angle. It is calculated by using voltage-second areas of the divided reference voltage according to the output voltage levels and these areas have influence on output step pulse waves. It is possible to reduce an amount of calculation because it is not required to solve the simultaneous equations by an iterative method. Also, the proposed method can get the conducting angle by means of on line.

  • PDF

Effects of Backward Walking Training with a Weighted Bag Carried on the Front on Craniocervical Alignment and Gait Parameters in Young Adults with Forward Head Posture: A case series

  • Byoung-Ha Hwang;Han-Kyu Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.83-91
    • /
    • 2024
  • Purpose : This case study aimed to investigate the effects of backward walking exercises with a front-loaded bag on craniovertebral angle (CVA), craniorotational angle (CRA), and gait variables in subjects with forward head posture (FHP). Methods : Two individuals in their twenties with FHP performed backward walking exercises on a treadmill while carrying a front-loaded bag with a load equivalent to 20 % of their body weight, for 30 minutes per day, three times a week, over two weeks. CVA and CRA were measured before and after the intervention using side view photographs taken from 1.5 meters away. CVA was calculated by marking C7, the tragus of the ear, and the outer canthus of the eye, and CRA was determined using the same landmarks. Image J software was used for angle analysis, with measurements taken three times and averaged. Gait variables such as step length and cadence were recorded using a step analysis treadmill and analyzed with the software included with the equipment, with measurements taken at baseline and after the two-week intervention. Results : Both participants demonstrated notable improvements in the CVA, indicating enhanced head alignment relative to the cervical spine. There was also a marked decrease in the CRA, suggesting a reduction in rotational misalignment. Although differences were observed in gait variables, such as step length and cadence, these changes were not consistent across measurements. The results suggest that backward walking exercises with a load carried in front can positively influence postural adjustments by aligning the cervical spine in individuals with FHP. Conclusion : The findings of this case study indicate that backward walking exercises with a front-loaded bag can effectively improve cervical spine alignment in individuals with FHP. Differences were observed in gait variables, such as step length and cadence, but these changes were not consistent across measurements. Future studies should explore these effects more comprehensively and consider optimizing the exercise protocol for better therapeutic outcomes.

Multi-step growth of a-plane GaN epitaxial layer on r-plane sapphire substrate by HVPE method (HVPE를 이용하여 r-plane 사파이어 위에 multi-step으로 성장시킨 a-plane GaN 에피층의 특성 연구)

  • Lee, Won-Jun;Park, Mi-Seon;Jang, Yeon-Suk;Lee, Won-Jae;Ha, Ju-Hyung;Choi, Young-Jun;Lee, Hae-Yong;Kim, Hong-Seung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this study, the crystalline property of a-plane GaN epitaxial layer grown on r-plane sapphire by a HVPE method has been investigated according to the V/III ratio and the growth time of multi-step growth. Furthermore, these results were compared with the previous result obtained from the single-step growth of a-plane GaN on r-plane sapphire substrate. In the multi-step growth for a-plane GaN epitaxial layer on r-plane sapphire, the FWHM values of rocking curve in GaN epitaxial layer were decreased as the HCl source flow rate and the growth time were increased. The void formed in epitaxial layer was continuously decreased as the growth time in first step and second step using a higher HCl flow rate was increased. As a result, the GaN layer obtained with the longest growth time on the first step and second step exhibited the lowest FWHM values of 584 arcsec and the smallest dependence of azimuth angle.

A study of quantitative correlation between step animation and emotional expressions (스텝 애니메이션과 감성 표현 사이의 정량적 상호관계에 관한 연구)

  • Lee, Ji-Sung;Jeong, Jae-Wook
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.141-148
    • /
    • 2004
  • The purpose of this study is to define the emotion that expressed in step animation and to quantify the intuitional expression of emotion that related step for using extract, measure, analysis the stimulate element about step. The survey of relation with 27 word of emotional expressions and 36 moving pictures of step sample is used for method of this test. The emotional mental structure is transferred to 2 dimensional planes as applying the results of analysis of integrated data using Quantification Method 3, which the integrated data is composed two axial - confidential axial and stabling axial. Analysis of distribution of 2 dimensional diagram shows that the second of the plane and the third of the plane have much data. However, the first of the plane and the forth of the plane have a little data. Through this kind of analysis of graph, it is difficult to express a different emotion between unstable the timidity mind and stable feel the timidity mind using only step analysis. Six difference types about physical elements affecting to emotion are selected and analyzed such as the paces of step, the rate of step, the movement angle of pelvis, the swing range of arm, angle of backbone and the lean angle of body. The result is that the rate of stop and the lean angle of body are the major element that effects to emotional stimulate of stop. This thesis argues about methods transforming subjective expression to objective and quantitative expression with the state of delicate emotion of character apply to step animation naturally. Those data to apply to multi-contents in future are the main target in this study.

  • PDF

The Effectiveness of the Use of Custom-Made Foot Orthotics on Temporal-Spatial Gait Parameters in Children With Spastic Cerebral Palsy

  • Kim, Sung-Gyung;Ryu, Young-Uk
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.16-23
    • /
    • 2012
  • This study examined the effects of custom-made foot orthotics on the temporal-spatial gait parameters in children with cerebral palsy. Twenty spastic bilateral cerebral palsy (spastic CP) children (11 boys and 9 girls) participated in this study. GAITRite was used to examine the velocity, cadence, step length differential, step length, stride length, stance time, single support time, double support time, base of support, and toe angle while walking with and without foot orthotics. The differences in temporal-spatial parameters were analyzed using paired t-test. The significance level was set at .05. The velocity, cadence, both step lengths, both stride lengths, both bases of support and right toe angle significantly increased when the children with spastic CP with foot orthotics compared to without foot orthotics (p<.05). The step length differential between the two extremities, left stance time and left single support time, significantly decreased with foot orthotics (p<.05). Right stance time, right single support time, both double support times and left toe angle showed little change (p>.05). This study demonstrated that foot orthotics were beneficial for children with spastic CP as a gait assistance tool.

Fabrication and characterization of $YBa_2Cu_3O_7$ step-edge Josephson junctions prepared on sapphire substrates

  • Lim, Hae-Ryong;Kim, In-Seon;Kim, Dong-Ho;Park, Yong-Ki;Park, Jong-Chul
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.146-150
    • /
    • 2000
  • Step edge Josephson junctions in c-axis oriented $YBa_2Cu_3O_7$ films were fabricated on $CeO_2$ buffered sapphire substrates. The step angle was controlled in the wide range of $20^{\circ}\sim75^{\circ}$ by the Ar ion milling technique. I-V curves of junction fabricated on the thickness ratio of $\sim$0.8 and the step angle of $35^{\circ}$ were exhibited RSJ-like behavior with $I_CR_N$ product of $\sim250{\mu}A$ and critical current density of $\sim2\times10^4A/cm^2$ at 77 K. Critical current of step edge junction was increased linearly with decreasing temperature but the normal resistance was almost constant. Total samples of step edge Josephson junction was satisfied a scaling behavior of $I_CR_N{\propto}(J_C)^{0.5}$.

  • PDF

A Kinematic Analysis of Gait Patterns between the Normal Men and the Lower Limb Handicapped (정상인과 하지장애자의 보행형태에 대한 운동학적 분석)

  • Kim, Moo-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.163-180
    • /
    • 2003
  • This paper aims at collecting the guantitative data of kenematic variables by analysing the gait patterns of the normal adult men and the handicapped. The gait motions were taped with 4 video cameras, the cinematographic analyses were performed by the DLT technique of three dimensional image treatment. The following results were obtained in the analysis of the variables: 1. The ratio of stance time and swing time did not show any significant difference in the groups of the normal men and the handicapped when both foot of the former and the right feet of the latter were compared. The stride peeriod time of these two groups were 1.12 and 1.11 second, respectively. 2. In the handicapped group, the step width was wider, the step length and stride length were shorter, and especially, the step length of the right foot was shorter, 3. The small vertical displacement of left toes of the handicapped group showed that the heal contact and the left midstance are almost simultaneous. 4. The two groups have almost the same horizontal displacement of the center of gravity and the same vertical rate of extension. In view of the velocity of the center of gravity the normal adults showed the constant speed of movement. However, the handicapped adults were reduced from the right midstance to the right toe-off. 5. The handicapped showed prominently low angle on the left toe-off in the ankle joint angle, they also had the tendency to walk in the patterns of extended knee in the knee joint angle. Both the handicapped and the normal had the hyperextension on the toe-off in the hip joint angle. In the back and front angle of body, both showed the slightly back-sided walking positions. 6. Both groups had the abduction of both feet in foot placement angle, but the handicapped did not show serious abduction of left midstance.