• 제목/요약/키워드: Stents, prosthesis

검색결과 7건 처리시간 0.026초

실험적 기관 재건술에 대한 고찰 (Review of Experimental Tracheal Reconstruction)

  • 성숙환;김용희
    • 대한기관식도과학회지
    • /
    • 제7권2호
    • /
    • pp.128-139
    • /
    • 2001
  • The purpose of this study was to review the literatures of experimental tracheal reconstruction. Although there have been significant advancements in the surgical treatment of the long circumferential tracheal injuries, there still has been a difficult problem with high morbidity and mortality. The method for tracheal reconstruction after circumferential resection is preferred end-to-end anastomosis for defects up to 6 cm in length, but larger tracheal defects require the use of tracheal allograft, various artificial prosthesis or autogenous organs. The tracheal allotransplantation has been widely used as there was significantly improved the method of surgical technique, preservation and immunosuppression. But it has been limited by a number of factors such as few donor, limited use of immunosuppressant, delayed revascularization and re-epitheliazation. Experimental studies on the tracheal prosthesis have a long history and they tried to use silicone, polytetrafluoroethylene, polypropylene mesh, Dacron, Marlex mesh, external or internal stents. Other experimental studies were reported the use of autogenous tissues that were cartilage. jejunum, aorta, skin, muscle, periostium or esophagus. But a great variety of these protheses have been resulted unsatisfactory in a significant Proportion of cases. Alternatively, the tissue-engineering technique has showed a new approach to reconstruct trachea and much progress in tissue-engineering bas been made recently. In conclusion, although the tracheal allotransplantation and the use of prosthesis and allograft have been reported a lot of limitation to overcome, we could sooner expect good result of ideal tracheal prosthesis.

  • PDF

컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가 (Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique)

  • 이지호;김성민;팽준영;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.

Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report

  • Noh, Kwantae;Choi, Woo-Jin;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.67-72
    • /
    • 2013
  • Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis using CAD-CAM technology.

Implant-assisted Removable Prosthetic Rehabilitation of a Patient with Crossed Occlusion

  • Oh, Hyun-Su;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Korean Dental Science
    • /
    • 제14권1호
    • /
    • pp.32-39
    • /
    • 2021
  • 'Crossed occlusion' is the condition in which occlusal intercuspation is lost when several teeth on upper and lower jaw remain. This report describes a clinical case in which a patient had two upper-left posterior teeth and two lower-right posterior teeth; typically known as left-right crossed occlusion. Considering the patient's general condition and financial situation, the treatment plan included placement of two implants on each jaw against the remaining teeth using surgical guide. To find out the ideal position of implants, digital diagnostic wax-up was preceded by superimposing the cast and cone beam computed tomography image, which was aided with radiographic stents. The consequent surveyed implant bridge provided stable vertical stop for fabrication of the implant assisted removable partial dentures. The patient was satisfied with the functionality and esthetics of definitive prosthesis.

Delayed Colon Perforation after Palliative Treatment for Rectal Carcinoma with Bare Rectal Stent: A Case Report

  • Young Min Han;Jeong-Min Lee;Tae-Hoon Lee
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.169-171
    • /
    • 2000
  • In order to relieve mechanical obstruction caused by rectal carcinoma, a bare rectal stent was inserted in the sigmoid colon of a 70-year-old female. The procedure was successful, and for one month the patient made good progress. She then complained of abdominal pain, however, and plain radiographs of the chest and abdomen revealed the presence of free gas in the subdiaphragmatic area. Surgical findings showed that a spur at the proximal end of the bare rectal stent had penetrated the rectal mucosal wall. After placing a bare rectal stent for the palliative treatment of colorectal carcinoma, close follow-up to detect possible perforation of the bowel wall is necessary.

  • PDF

Nutcracker Syndrome를 위해 왼콩팥정맥에 삽입한 스텐트의 우심실 이동 - 1예 보고 - (Intracardiac Migration of a Renal Stent from the Left Renal Vein to the Right Ventricle during the Treatment of Nutcracker Syndrome - A case report -)

  • 김재범;최세영;박남희;금동윤;박훈;황은아
    • Journal of Chest Surgery
    • /
    • 제43권1호
    • /
    • pp.100-103
    • /
    • 2010
  • 저자들은 nutcracker syndrome을 치료하기 위해 삽입한 스텐트가 심장내 우심실로 이동하는 드문 합병증을 경험하였기에 보고하고자 한다. 29세 여자환자가 측복부 통증을 주소로 내원하였다. 복부 컴퓨터단층촬영에서 좌콩팥정맥이 복부대동맥과 상장간막동맥 사이에서 눌리는 것(nutcracker syndrome)이 발견되었다. Nutcracker syndrome을 치료하기 위해 자가확장 스텐트를 좌콩팥정맥에 삽입하는데 다음날 스텐트가 심장 내 우심실로 이동된 것을 발견할 수 있었다. 경피적 스텐트 제거를 시도하였으나 실패하여 심장수술로 제거하였다. 수술 후 6개월째 아무런 복부나 심장 증상없이 외래 추적관찰 중이다.

관상동맥질환 치료를 위한 생체흡수형스텐트의 개발 동향 (The Developing Trend in Bioresorbable Stent for Treatment of Coronary Artery Disease)

  • 정경원;김태훈;나재운;박준규
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.497-502
    • /
    • 2018
  • 협심증, 심근경색과 같은 관상동맥 질환은 급속도로 증가하고 있다. 관상동맥 질환은 콜레스테롤과 칼슘과 같은 플라크들이 혈관벽에 흡착되어 발생한다. 심혈관 중재시술은 풍선 카테터와 금속스텐트를 이용하여 좁아진 관상동맥혈관을 확장시키는 비수술적 시술방법이다. 금속재질의 스텐트는 관상동맥질환에 의한 사망자를 감소시키는데 효과적이었지만 영구적으로 혈관에 금속재질 스텐트가 이식되어 있기 때문에 지속적인 염증과 후기 혈전증 등이 발생되었다. 따라서, 스텐트와 같은 영구적 보철물에 의한 합병증과 재협착 등을 해결하기 위한 생체 흡수성 혈관 지지체의 개발은 급속도로 증가되고 있다. 이 리뷰에서는 생체흡수형스텐트의 성공적인 개발을 위한 동향에 대해서 논하고자 한다.