• Title/Summary/Keyword: Stent placement

Search Result 108, Processing Time 0.023 seconds

Lung lobe torsion in a dog with a tracheal stent for severe tracheal collapse

  • Taeho Lee;Aryung Nam;Dong-Kwan Lee;Han-Joon Lee;Kun-Ho Song
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.349-355
    • /
    • 2023
  • A 7-year-old castrated male Pomeranian dog presented with severe goose honking cough and dyspnea. Thoracic radiographs revealed a narrowed tracheal diameter at the thoracic inlet, classified as tracheal collapse grade 4. Despite medical treatment, the dog's life-threatening airway obstruction did not improve. Subsequently, tracheal stent placement resulted in a significant improvement in respiratory condition, with no recurrence of symptoms observed during the 4-month period, except for coughing induced by excitement and anxiety. However, the patient presented with a one-week history of productive cough, exercise intolerance, and loss of appetite. Radiographs and computed tomography scans revealed torsion of the left cranial lung lobe. The patient underwent affected lung lobectomy, which involved the removal of the necrotized cranial portion and heavily congested caudal portion. Unfortunately, the patient did not recover and eventually passed away. Histopathological examination of the resected lung tissue confirmed coagulative necrosis and marked peribronchiolar edema, consistent with lung lobe torsion.

Tuberculous Aneurysm of the Abdominal Aorta: Endovascular Repair Using Stent Grafts in Two Cases

  • Wei Chiang Liu;Byung Kook Kwak;Kyo Nam Kim;Soon Yong Kim;Joung Joo Woo;Dong Jin Chung;Ju Hee Hong;Ho Sung Kim;Chang Jun Lee;Hyung Jin Shim
    • Korean Journal of Radiology
    • /
    • v.1 no.4
    • /
    • pp.215-218
    • /
    • 2000
  • Tuberculous aneurysm of the aorta is exceedingly rare. To date, the standard therapy for mycotic aneurysm of the abdominal aorta has been surgery involving in-situ graft placement or extra-anatomic bypass surgery followed by effective anti-tuberculous medication. Only recently has the use of a stent graft in the treatment of tuberculous aortic aneurysm been described in the literature. We report two cases in which a tuberculous aneurysm of the abdominal aorta was successfully repaired using endovascular stent grafts. One case involved is a 42-year-old woman with a large suprarenal abdominal aortic aneurysm and a right psoas abscess, and the other, a 41-year-old man in whom an abdominal aortic aneurysm ruptured during surgical drainage of a psoas abscess.

  • PDF

Superior Vena Cava Syndrome Caused by Tumor Thrombus from Papillary Thyroid Carcinoma (갑상선 유두암의 암성 혈전으로 인한 상공 정맥 증후군 1예)

  • Yun, Ji-Sup;Lee, Jan-Dee;Lim, Chi-Young;Nam, Kee-Hyun;Chung, Woong-Youn;Park, Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.2
    • /
    • pp.188-191
    • /
    • 2006
  • Papillary thyroid carcinoma is rarely associated with macroscopic vascular invasion or tumor thrombosis. Especially, superior vena cava syndrome(SVCS) resulted from tumor thrombosis of papillary thyroid carcinoma is extremely rare. We present herein a case of SVCS caused by tumor thrombosis from papillary thyroid carcinoma which was successfully solved by intravascular placement of self-expandable stent in 74-year-old woman.

Stent-assisted Angioplasty for Symptomatic Radiation-induced Carotid Stenosis

  • Kwon, Yoon-Kwang;Kim, Eal-Maan;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.327-329
    • /
    • 2007
  • A 44-year-old woman presented with recurrent, transient episodes of left-side hemiparesis. She had received a radiation dose of 6120 cGy to her cervical region for parotid gland carcinoma 13 years previously. Cerebral angiography revealed a long, irregular tight stenosis involving the right extracranial internal carotid artery [ICA] and common carotid artery [CCA], measuring approximately 90% at the most severe narrowing according to North American Symptomatic Carotid Endarterectomy Trial criteria. Endovascular stent placement resulted in restoration of the carotid lumen to about 80% of its original diameter. She showed no further ischemic events during the follow-up period of 48 months. Our clinical and angiographic findings suggest that carotid stenting is considered a safe and effective treatment option in patients with radiation-induced carotid stenosis.

Hyperperfusion Syndrome after Carotid Stent-Supported Angioplasty in Patients with Autonomic Dysfunction

  • Kim, Dong-Eun;Choi, Seong-Min;Yoon, Woong;Kim, Byeong C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.476-479
    • /
    • 2012
  • Cerebral hyperperfusion syndrome (CHS) is a rare, serious complication of carotid revascularization either after carotid endarterectomy or carotid stent placement. Although extensive effort has been devoted to reducing the incidence of CHS, little is known about the prevention. Postprocedural hypertension is very rare due to autoregulation of carotid baroreceptors but may occur if presented with autonomic dysfunction. We present two cases of CHS after cerebral revascularization that presented autonomic dysfunction.

Endovascular Aneurysm Repair for Abdominal Aortic Aneurysm: A Comprehensive Review

  • Hyoung Ook Kim;Nam Yeol Yim;Jae Kyu Kim;Yang Jun Kang;Byung Chan Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1247-1265
    • /
    • 2019
  • Abdominal aortic aneurysm (AAA) can be defined as an abnormal, progressive dilatation of the abdominal aorta, carrying a substantial risk for fatal aneurysmal rupture. Endovascular aneurysmal repair (EVAR) for AAA is a minimally invasive endovascular procedure that involves the placement of a bifurcated or tubular stent-graft over the AAA to exclude the aneurysm from arterial circulation. In contrast to open surgical repair, EVAR only requires a stab incision, shorter procedure time, and early recovery. Although EVAR seems to be an attractive solution with many advantages for AAA repair, there are detailed requirements and many important aspects should be understood before the procedure. In this comprehensive review, fundamental information regarding AAA and EVAR is presented.

Portal cavernography during endoscopic retrograde cholangiopancreatography: from bilhemia to hemobilia

  • Rawad A. Yared;Paraskevas Gkolfakis;Arnaud Lemmers;Vincent Huberty;Thierry Degrez;Jacques Deviere;Daniel Blero
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.521-526
    • /
    • 2023
  • Portobiliary fistulas are rare but may lead to life-threatening complications. Biliary plastic stent-induced portobiliary fistulas during endoscopic retrograde cholangiopancreatography have been described. Herein, we present a case of portal cavernography and recurrent hemobilia after endoscopic retrograde cholangiopancreatography in which a portobiliary fistula was detected in a patient with portal biliopathy. This likely indicates a change in clinical presentation (from bilhemia to hemobilia) after biliary drainage that was successfully treated by placement of a fully covered, self-expandable metallic stent.

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

Planning of Dental Implant Placement Using 3D Geometric Processing and Finite Element Analysis (3차원 기하 처리와 유한요소 분석을 이용한 치아 임플란트 식립 계획 수립)

  • Park, Hyung-Wook;Park, Chul-Woo;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.4
    • /
    • pp.253-261
    • /
    • 2012
  • In order to make dental implant surgery successful, it is important to perform proper planning for dental implant placement. In this paper, we propose a decent approach to dental implant placement planning based on geometric processing of 3D models of jawbones, a nerve curve and neighboring teeth around a missing tooth. Basically, the minimum enclosing cylinders of the neighboring teeth around the missing tooth are properly used to determine the position and direction of the implant placement. The position is computed according to the radii of the cylinders and the center points of their top faces. The direction is computed by the weighted average of the axes of the cylinders. For a cylinder whose axis passes the position along the direction, its largest radius and longest length are estimated such that it does not interfere with the neighboring teeth and the nerve curve, and they are used to select the size and type of an implant fixture. From the geometric and spatial information of the jawbones, the teeth and the fixture, we can construct the 3D model of a surgical guide stent which is crucial to perform the drilling operation with ease and accuracy. We have shown the validity of the proposed approach by performing the finite element analysis of the influence of implant placement on bone stress distribution. Adopted in 3D simulation of dental implant placement, the approach can be used to provide dental students with good educational contents. It is also expected that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

Cardiac Intracoronary Stenting vs CABG: Prevention of Medical Accident (심장 스텐트 시술과 의료사고 예방)

  • Kim, Kyoung Reay;Park, Kook Yang
    • The Korean Society of Law and Medicine
    • /
    • v.18 no.2
    • /
    • pp.163-194
    • /
    • 2017
  • Coronary artery disease has increased in Korea as the country enters the aged society. It is well known that the incidence of coronary artery disease is related to aging, hypertension, diabetes, hyperlipidemia, and dietary habit. For effective treatment of significant coronary stenosis, close coordination between cardiac surgery and cardiology team is essential. Especially cardiologists' decision whether to do the stent placement or CABG is very important because the cardiologists usually start to consult the patients for their treatment. Recently, non-surgical interventions(that is stent placement) in cardiology field have dramatically increased as the national insurance system removed the limitation of the number of stents deployed. However, accidents are often caused by inappropriate use of stents, especially in patients with triple coronary disease or left main disease with heavy coronary calcifications. Another aspect of stent placement is to cope with an emergency case in the event of coronary rupture or pericardial tamponade during coronary interventions without cardiac surgeons. In the past two years, the Korea Consumer Agency (Consumer Dispute Coordination Committee) analyzed eight cases of medical dispute settlement. Only two hospitals were manned with both cardiologists and cardiac surgeons. Seven patients died of procedures of stenting and five patients died on the day of the procedure. Among the 8 cases, 5 cases showed 3 vessel disease and the rest of the cases had either severe calcification, complete occlusion or poor coronary antomies for stenting According to a 2017 national data registry of coronary stenting, less than 3 drug-eluting stents were implanted in 98% of all patients. In 2015, the number of stent procedures was 38,922, and approximately in 800 (2%) cases, more than four stents were used per patient. We emphasize that it is necessary to seriously consider the cost-benefit analysis between stent and CABG. The patient has the right to choose the right procedure by asking the liability of 'instruction explanation obligation'. He should be well informed of the pros and cons of both procedures to avoid overuse of stent. It can be solved by intimate discussion of individual cases with the cardiac surgeon and the patient. Unilateral dialogue with the patient, forceful restriction on the number of stenting, lack of surgeon's backup in difficult cases should all be avoided. It is also necessary to solve the problem not only at the hospital level, such as multidisciplinary integrated medical care, but also a nationwide solution such as expanding cardiac surgeons as essential personnel to public officials.

  • PDF