• Title/Summary/Keyword: Stent migration

Search Result 37, Processing Time 0.024 seconds

Evaluation of a Double-Pigtail Ureteral Stent Fixation in Cats with Complete Ureteral Obstruction

  • Shin, Kyoung-in;Jeong, Soon-wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.115-122
    • /
    • 2020
  • The aim of this study was to evaluate double-pigtail ureteral stent fixation in cats. Medical records of 19 cats (23 ureters) with complete ureteral obstruction that double-pigtail ureteral stent placement were carried out were retrospectively reviewed. The cats were randomly classified into two groups; 13 cats (16 ureters) with double-pigtail ureteral stent fixed to urinary bladder (SF group) and 6 cats (7 ureters) with not fixed to urinary bladder (SNF group). The average age and weight of the cats was 7.4 years and 3.73 kg, respectively. Postoperative complications included chronic renal failure (n = 11), lower urinary track diseases (cystitis, hematuria, pollakiuria) (n = 7), stent migration (n = 6), anemia (n = 5), ascites (n = 2), hyperthermia (n = 1), enteritis (n = 1), oliguria (n = 1), hypotension (n = 1), ureteritis (n = 1), and pyelonephritis (n = 1). Stent migration did not occur in the 16 ureters of the cats in SF group but did occur in 4 out of 7 ureters of the cats in SNF group. The prevention of stent migration by stent fixation was significant (P = 0.04). Among the 13 cats in SF group, only 2 cats developed lower urinary track diseases, while 4 of the 6 cats in SNF group showed symptoms of lower urinary track disease. Thus, the cats that underwent double-pigtail ureteral stent fixation to the urinary bladder developed significantly fewer lower urinary diseases (P = 0.046). In conclusion, double-pigtail ureteral stent fixation to the urinary bladder for treatment of complete ureteral obstruction in cats can effectively prevent stent migration, which is common complication of stent placement.

Jejunal Migration of the Stent-Graft Used for Common Hepatic Artery Pseudoaneurysm (총간동맥 가성동맥류의 치료로 삽입한 스텐트 그라프트의 공장으로의 위치 이동)

  • Jiwon Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.189-193
    • /
    • 2022
  • Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study

  • Arata Sakai;Atsuhiro Masuda;Takaaki Eguchi;Keisuke Furumatsu;Takao Iemoto;Shiei Yoshida;Yoshihiro Okabe;Kodai Yamanaka;Ikuya Miki;Saori Kakuyama;Yosuke Yagi;Daisuke Shirasaka;Shinya Kohashi;Takashi Kobayashi;Hideyuki Shiomi;Yuzo Kodama
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2024
  • Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO. Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events. Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration. Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Complications of Endotracheal Stent in Three Dogs with Tracheal Collapse (기관허탈이 있는 개들에서 기관 내 Stent 장착 후 나타난 합병증 3례)

  • Seo, Kyoung-Won;Lee, Young-Heun;Chang, Jin-Hwa;Hwang, Cheol-Yong;Yoon, Jung-Hee;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.457-461
    • /
    • 2010
  • Three dogs were presented with signs of recurrence of coughing, dyspnea and difficulty of barking after endotracheal stent placement. On the basis of history taking, physical examination, laboratory tests and radiography, complications of endotracheal stent were suspected. Dog 1 had unfitted stent diameter (stent diameter is larger than tracheal diameter) and getting disentangled of proximal tracheal stent wire. Dog 2 was suspected a foreign body reaction. Dog 3 had the migration of stent caudally. Based on these cases, the veterinarian should accurately evaluate the indicated patients before endotracheal stent and has to select the appropriate stent (diameter, length and location) to prevent complications after endotracheal stent and concern the regular follow-ups to assure proper endotracheal stent placement.

Migrated Pancreaticojejunal Stent Forming a Stent-Stone Complex in the Jejunum with Resultant Small Bowel Obstruction: A Case Report (췌공장 스텐트의 공장으로의 이동으로 발생한 스텐트-돌 복합체 형성과 이로 인한 소장폐색: 증례 보고)

  • Jiwon Kim;Young Han Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.512-517
    • /
    • 2023
  • Transanastomotic pancreatic duct stent placement during reconstruction following pancreaticoduodenectomy is widely performed to prevent postoperative pancreatic fistulas and duct stenosis. However, stent-related complications, such as stent occlusion and migration, may occur. Here, we report a rare case of a migrated pancreatic duct plastic stent. After pylorus-preserving pancreaticoduodenectomy, the stent migrated to the jejunum and served as a nidus of the stent-stone complex, which developed jejunal obstruction. The stent-stone complex was removed by explorative laparotomy.

Mechanical Property and Problems of the Self-expandable Metal Stent in Pancreaticobiliary Cancer

  • Thanawat Luangsukrerk
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.2
    • /
    • pp.92-98
    • /
    • 2022
  • Self-expandable metal stent (SEMS) is effective for biliary drainage, especially in pancreaticobiliary cancer. The mechanical properties, material, and design of SEMS are important in preventing recurrent biliary obstruction and complication. Radial and chronic expansion forces play roles in preventing stent migration and collapse. Complications, such as stent impaction, cholecystitis, and pancreatitis, were related to the axial force. The nickel-titanium alloy shows more flexibility, conformability, and optimal axial force compared to previously used stainless steel. Additionally, the stent structure affected the mechanical properties of SEMS. Therefore, understanding the mechanical properties, material, and design of SEMS will provide the best outcome for biliary drainage, as well as better SEMS development.

The efficacy of a novel integrated outside biliary stent and nasobiliary drainage catheter system for acute cholangitis: a single center pilot study

  • Naosuke Kuraoka;Tetsuro Ujihara;Hiromi Kasahara;Yuto Suzuki;Shun Sakai;Satoru Hashimoto
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.795-801
    • /
    • 2023
  • Background/Aims: Endoscopic biliary drainage is the gold standard treatment for cholangitis. The two methods of biliary drainage are endoscopic biliary stenting and nasobiliary drainage. A novel integrated outside biliary stent and nasobiliary drainage catheter system (UMIDAS NB stent; Olympus Medical Systems) was recently developed. In this study, we evaluated the efficacy of this stent in the treatment of cholangitis caused by common bile duct stones or distal bile duct strictures. Methods: We conducted a retrospective pilot study by examining the medical records of patients who required endoscopic biliary drainage for cholangitis due to common bile duct stones or distal bile duct strictures, and who were treated with a UMIDAS NB stent, between December 2021 and July 2022. Results: Records of 54 consecutive patients were reviewed. Technical and clinical success rates were 47/54 (87.0%) and 52/54 (96.3%), respectively. Adverse events were observed in 12 patients, with six patients experiencing pancreatitis as an adverse event, following endoscopic retrograde cholangiopancreatography (ERCP). Regarding late adverse events, five cases of biliary stent migration into the bile duct were observed. Disease-related death occurred in one patient. Conclusions: The outside-type UMIDAS NB stent is an efficacious new method for biliary drainage and can be applied to many indications.

Comparison of Outcomes between 7-French and 10-French Plastic Stents for Patients with Biliary Tract Cancer (담도암 환자에서 7-프렌치와 10-프렌치 플라스틱 스텐트의 결과 비교)

  • Lee, Kyong Joo;Kang, Yong Seok;Seong, Jae Ho;Jung, Saehyun;Kim, Jae Woo
    • The Korean Journal of Pancreas and Biliary Tract
    • /
    • v.22 no.4
    • /
    • pp.165-171
    • /
    • 2017
  • Background/Aim: There is little data on whether plastic stents with a larger diameter are patent for longer than small stents in patients with bile duct cancer. The aim of this study was to compare the stent survival between 7-French (Fr) and 10-Fr plastic stents and evaluate the factors affecting stent survival. Methods: Patients with biliary obstruction due to biliary tract cancer were enrolled at Yonsei University Wonju College of Medicine from January 2010 to October 2014. Results: A total of 215 patients (7-Fr:10-Fr = 89:126 patients) were retrospectively enrolled. The primary tumor sites were common bile duct (n = 111), hilar (n = 45), and ampulla of Vater (n = 59). Rates of stent migration and stent obstruction were not different between the two groups. The median duration of stent survival was 3.3 months in the 7-Fr group and 5.9 months in the 10-Fr group (p = 0.543). The diameter of the stent did not have an effect on stent survival (hazard ratio 1.11, 95% confidence interval 0.71-1.73, p = 0.649). Conclusions: 7-Fr and 10-Fr stents have similar rates of stent migration and stent obstruction. The stent survival of 7-Fr was not inferior to 10-Fr stents in the management of biliary tract cancer.