• Title/Summary/Keyword: Stent migration

Search Result 45, Processing Time 0.023 seconds

Evaluation of a Double-Pigtail Ureteral Stent Fixation in Cats with Complete Ureteral Obstruction

  • Shin, Kyoung-in;Jeong, Soon-wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.115-122
    • /
    • 2020
  • The aim of this study was to evaluate double-pigtail ureteral stent fixation in cats. Medical records of 19 cats (23 ureters) with complete ureteral obstruction that double-pigtail ureteral stent placement were carried out were retrospectively reviewed. The cats were randomly classified into two groups; 13 cats (16 ureters) with double-pigtail ureteral stent fixed to urinary bladder (SF group) and 6 cats (7 ureters) with not fixed to urinary bladder (SNF group). The average age and weight of the cats was 7.4 years and 3.73 kg, respectively. Postoperative complications included chronic renal failure (n = 11), lower urinary track diseases (cystitis, hematuria, pollakiuria) (n = 7), stent migration (n = 6), anemia (n = 5), ascites (n = 2), hyperthermia (n = 1), enteritis (n = 1), oliguria (n = 1), hypotension (n = 1), ureteritis (n = 1), and pyelonephritis (n = 1). Stent migration did not occur in the 16 ureters of the cats in SF group but did occur in 4 out of 7 ureters of the cats in SNF group. The prevention of stent migration by stent fixation was significant (P = 0.04). Among the 13 cats in SF group, only 2 cats developed lower urinary track diseases, while 4 of the 6 cats in SNF group showed symptoms of lower urinary track disease. Thus, the cats that underwent double-pigtail ureteral stent fixation to the urinary bladder developed significantly fewer lower urinary diseases (P = 0.046). In conclusion, double-pigtail ureteral stent fixation to the urinary bladder for treatment of complete ureteral obstruction in cats can effectively prevent stent migration, which is common complication of stent placement.

Migrated coil and damaged stent removal during coil embolization, using an additional, retrievable stent: A case report

  • Hee Seung Noh;Sung Chan Park;Jong Min Lee;Soon Chan Kwon
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.196-202
    • /
    • 2023
  • One of the common complications that can occur during coil embolization of cerebral aneurysms, is migration of coil lump alone. The removal of these migrated coils has been reported on a few occasions. On the other hand, rare complications would include the migration of the coil with subsequent stent dislocation. Currently, there is no standardized method to correct the complications of stent dislocation, and very few instances of this complication have been reported previously. In this report, we introduce a case of coil migration combined with stent dislocation. This occurred during coil embolization of an unruptured aneurysm of the distal, left internal carotid artery for a 52-year old woman. We retrieved both the damaged stent and migrated coil using another retrievable stent successfully with no more further complications. In the present report, we describe in detail how we corrected the complication successfully stent, and we discuss why this rescue maneuver is reasonable option for the complication mentioned above.

Jejunal Migration of the Stent-Graft Used for Common Hepatic Artery Pseudoaneurysm (총간동맥 가성동맥류의 치료로 삽입한 스텐트 그라프트의 공장으로의 위치 이동)

  • Jiwon Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.189-193
    • /
    • 2022
  • Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study

  • Arata Sakai;Atsuhiro Masuda;Takaaki Eguchi;Keisuke Furumatsu;Takao Iemoto;Shiei Yoshida;Yoshihiro Okabe;Kodai Yamanaka;Ikuya Miki;Saori Kakuyama;Yosuke Yagi;Daisuke Shirasaka;Shinya Kohashi;Takashi Kobayashi;Hideyuki Shiomi;Yuzo Kodama
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2024
  • Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO. Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events. Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration. Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Laser-cut-type versus braided-type covered self-expandable metallic stents for distal biliary obstruction caused by pancreatic carcinoma: a retrospective comparative cohort study

  • Koh Kitagawa;Akira Mitoro;Takahiro Ozutsumi;Masanori Furukawa;Yukihisa Fujinaga;Kenichiro Seki;Norihisa Nishimura;Yasuhiko Sawada;Kosuke Kaji;Hideto Kawaratani;Hiroaki Takaya;Kei Moriya;Tadashi Namisaki;Takemi Akahane;Hitoshi Yoshiji
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.434-442
    • /
    • 2022
  • Background/Aims: Covered self-expandable metallic stents (CMSs) are widely used for malignant distal biliary obstructions (MDBOs) caused by pancreatic carcinoma. This study compared the efficacy and safety of the laser-cut-type and braided-type CMSs. Methods: To palliate MDBOs caused by pancreatic carcinoma, the laser-cut-type CMSs was used from April 2014 to March 2017, and the braided-type CMSs was used from April 2017 to March 2019. The tested self-expandable metallic stents were equipped with different anti-migration systems. Results: In total, 47 patients received CMSs for MDBOs (24 laser-cut type, 23 braided-type). The time to recurrent biliary obstruction (TRBO) was significantly longer in the braided-type CMSs (p=0.0008), and the median time to stent dysfunction or patient death was 141 and 265 days in the laser-cut-type CMSs and braided-type CMSs, respectively (p=0.0023). Stent migration was the major cause of stent dysfunction in both groups, which occurred in 37.5% of the laser-cut-type CMSs and 13.0% of the braided-type CMSs. There were no differences in the survival duration between the groups. Conclusions: The TRBO was significantly longer for the braided-type CMSs with an anti-migration system than for the laser-cut-type. Stent migration tended to be less frequent with the braided-type CMSs than with the laser-cut-type CMSs.

Complications of Endotracheal Stent in Three Dogs with Tracheal Collapse (기관허탈이 있는 개들에서 기관 내 Stent 장착 후 나타난 합병증 3례)

  • Seo, Kyoung-Won;Lee, Young-Heun;Chang, Jin-Hwa;Hwang, Cheol-Yong;Yoon, Jung-Hee;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.457-461
    • /
    • 2010
  • Three dogs were presented with signs of recurrence of coughing, dyspnea and difficulty of barking after endotracheal stent placement. On the basis of history taking, physical examination, laboratory tests and radiography, complications of endotracheal stent were suspected. Dog 1 had unfitted stent diameter (stent diameter is larger than tracheal diameter) and getting disentangled of proximal tracheal stent wire. Dog 2 was suspected a foreign body reaction. Dog 3 had the migration of stent caudally. Based on these cases, the veterinarian should accurately evaluate the indicated patients before endotracheal stent and has to select the appropriate stent (diameter, length and location) to prevent complications after endotracheal stent and concern the regular follow-ups to assure proper endotracheal stent placement.

Migrated Pancreaticojejunal Stent Forming a Stent-Stone Complex in the Jejunum with Resultant Small Bowel Obstruction: A Case Report (췌공장 스텐트의 공장으로의 이동으로 발생한 스텐트-돌 복합체 형성과 이로 인한 소장폐색: 증례 보고)

  • Jiwon Kim;Young Han Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.512-517
    • /
    • 2023
  • Transanastomotic pancreatic duct stent placement during reconstruction following pancreaticoduodenectomy is widely performed to prevent postoperative pancreatic fistulas and duct stenosis. However, stent-related complications, such as stent occlusion and migration, may occur. Here, we report a rare case of a migrated pancreatic duct plastic stent. After pylorus-preserving pancreaticoduodenectomy, the stent migrated to the jejunum and served as a nidus of the stent-stone complex, which developed jejunal obstruction. The stent-stone complex was removed by explorative laparotomy.