• Title/Summary/Keyword: Stent dislodgement

Search Result 3, Processing Time 0.017 seconds

Retrieval of a dislodged and dismounted coronary stent; using a rendezvous and snare technique at the brachial artery level via femoral approach

  • Jeong, Min-Woong;Sohn, Chang-Bae;Kim, Su Hong;Park, Jong-Ik;Park, Se-Ryeong;Min, Jun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.138-141
    • /
    • 2016
  • Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.

Experiences of Neuroform Stent Applications for Ruptured Anterior Communicating Artery Aneurysms with Small Parent Vessel

  • Yun, Jung-Ho;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.53-58
    • /
    • 2010
  • Objective : The purpose of this study was to review the safety and durability of aneurysms treated with stent-assisted coiling of ruptured anterior communicating artery aneurysms with small parent vessels (< 2.0 mm). Methods : Retrospective review of all ruptured aneurysm treated with stent assisted endovascular coiling between March 2005 and March 2009 at our institution was conducted. We report 11 cases of the Neuroform stent placement into cerebral vessels measuring less than 2.0 mm in diameter (range, 1.3-1.9 mm) in anterior cerebral artery. Clinical follow-up ranged from 3 to 12 months and imaging follow-up was performed with cerebral angiography at 6 months and 12 months after discharge. Results : Complete occlusion was achieved in 10 patients, and a remnant neck was evident in one. No stent displacement or no dislodgement occurred during stent placement. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. We performed follow-up angiography in all patients at 6 months and/or 12 months from the first procedure. The follow-up angiographic data showed successfully results except one in-stent stenosis case. All patients improved clinical performances except one patient with severe vasospasm who showed poor clinical condition initially. Conclusion : We have safely and successfully treated 11 vessels smaller than 2.0 mm in diameter with self-expanding stents with good short and intermediate term results. More clinical data with longer follow-ups are needed to establish the role of stent-assisted coiling in ruptured aneurysms with small parent vessels.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.