• Title/Summary/Keyword: Stenotic Artery

Search Result 60, Processing Time 0.027 seconds

Angiographic Results of Radial Artery Grafts that are Used for Myocardial Revascularization (관상동맥 우회술 후 혈관조영술을 이용한 요골동맥의 개통률 분석)

  • Yie, Kil-Soo;Oh, Sam-Sae;Kim, Jae-Hyun;Shinn, Sung-Ho;Kim, Soo-Cheol;Seo, Hong-Joo;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.546-551
    • /
    • 2007
  • Background: The radial artery is gaining widespread acceptance as complementary arterial conduits for surgical myocardial revascularization, but there have been limited reports about its angiographic patency compared with that of internal thoracic artery or saphenous vein. We tried to evaluate angiographic patency of radial artery graft and to compare that of radial artery and other gratis with retrospective manner. Material and Method: From January 2001 to Jure 2006, totally 132 patients (male 92, female 40) who underwent coronary artery bypass graft using radial artery were re-admitted to our hospital for follow up angiographic examination. Mean age was 58.2+8.87 and mean follow up duration was 32 month ($2{\sim}110$ month). Off pump and on pump bypass surgery were performed 74 and 58 patients respectively. Along with radial artery, left internal thoracic arteries were used in 57 cases, concomitant left internal thoracic artery and saphenous veins were used in 47 cases and bilateral internal thoracic arteries were used in 20 cases. Result: Totally 412 distal anastomosis were performed and 376 anastomosis remained patent (91.2%). Left internal thoracic artery showed the most excellent patency in all of the conduits (98.5%). Radial artery graft patency was 90.8% (169/186). There was no statistical difference of the patency by conduit between on-pump and off-pump group. But radial artery showed more higher patency rate (98/110, 89%) in the severe stenotic lesion that preoperatively revealed more than 90% stenosis than in the lesser severe (<90%) stenotic lesion (60/76, 78%)(p < 0.005). Radial artery conduit represented the worst result when it was grafted in the right coronary system. But when it was positioned in the left heart especially diagonal or obtuse marginal area, patency was comparable with left internal thoracic artery. Conclusion: Radial artery graft showed good midterm patency when it was used in the severe stenotic lesion more than 90% and left coronary system. But great notice should be taken when it is grafted in the right coronary system or less severe stenotic lesion.

Evaluation of Non-infarct-Related Arteries Using C-11 Acetate PET in STEMI With Multivessel Disease

  • Sang-Geon Cho;Minchul Kim;Seung Hun Lee;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.3
    • /
    • pp.169-180
    • /
    • 2022
  • BACKGROUND: We analyzed whether C-11 acetate positron emission tomography (PET) can be used for the evaluation of non-infarct-related artery (NIRA) in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. METHODS: We prospectively enrolled 31 patients with STEMI and at least one NIRA stenosis (diameter stenosis [DS] ≥ 50%). C-11 acetate PET was performed after successful revascularization for the infarct-related artery (IRA). Myocardial blood flow (MBF) and oxidative metabolism (kmono) were measured and compared between NIRA vs. IRA, stenotic (DS ≥ 50%) vs. non-stenotic (DS < 50%) NIRAs, and NIRAs with significant stenosis (DS ≥ 70% or fractional flow reserve [FFR] ≤ 0.80) vs. those without (neither DS ≥ 70% nor FFR ≤ 0.80). The correlations between PET and angiographic parameters were also analyzed. RESULTS: MBF and kmono were significantly higher in NIRAs than those in IRAs. Stenotic NIRAs showed significantly reduced stress MBF, myocardial flow reserve (MFR), relative flow reserve (RFR) (0.72 ± 0.12 vs. 0.82 ± 0.14; p = 0.001), and stress kmono, as compared to those in non-stenotic NIRAs. NIRAs with significant stenosis had significantly lower stress MBF, MFR, and RFR (0.70 ± 0.10 vs. 0.80 ± 0.14; p = 0.001). RFR showed the best, but modest linear correlation with DS of NIRA stenosis (r = -0.429, p = 0.001). RFR > 0.81 could effectively exclude the presence of significant NIRA stenosis. CONCLUSIONS: C-11 acetate PET could be a feasible alternative noninvasive modality in patients with STEMI and multivessel disease, by excluding the presence of significant NIRA stenosis.

Spontaneous resolution of new coronary artery aneurysm following guideline-directed medical therapy after drug-eluting stent implantation

  • Jae-Geun Lee;Ki Yung Boo
    • Journal of Medicine and Life Science
    • /
    • v.20 no.3
    • /
    • pp.131-134
    • /
    • 2023
  • Here, we present a case of a 56-year-old man with acute myocardial infarction. The patient underwent percutaneous coronary intervention (PCI) at the left main bifurcation and mid-left anterior descending artery using drugeluting stents. Four months after the PCI, the patient was readmitted for cardiac arrest. Coronary angiography (CAG) revealed stent thrombosis in the left main-to-proximal left anterior descending artery and in-stent restenosis in the left main-to-proximal left circumflex artery. We performed balloon angioplasty at the left main to mid-left anterior descending artery and left main to proximal left circumflex artery stents; subsequently, blood flow was fully restored. However, contrast agent extravasation was observed outside the mid-portion of the left main artery to the proximal left anterior descending artery stent, indicating the presence of a coronary artery aneurysm (CAA) outside the stent. After guideline-directed medical therapy with dual antiplatelet agents and high-intensity statins, follow-up CAG revealed near-resolution of the CAA, absence of stenotic lesions, and good blood flow.

Flow comparison between Stenosed Coronary and Abdominal Arteries (협착된 관상동맥과 복부 대동맥의 유동 특성 비교)

  • Kim, M.C.;Lee, C.S.;Kim, C.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.585-590
    • /
    • 2001
  • The hemodynamic characteristics were compared using commercial CFD code for the stenosed coronary and abdominal arteries. Numerical calculations were carried out in the axisymmetric arteries over the stenotic diameter ratios ranging from 0.25 to 0.875 (6 cases) employing the typical physiological flow conditions. In case of the coronary artery, there was only one recirculation zone observed distal to the stenosis throat during the major portion of the period. However, in case of the abdominal aorta, there were complex recirculation regions found proximal and distal to stenosis throat. For both models, the wall shear stresses(WSS) increased sharply in the converging stenosis, reaching a peak just upstream of the throat, and became negative or low values in the post-stenotic recirculation region. As the results, the oscillatory shear index(OSI) was abruptly increased at the stenosis throat. For the coronary stenosis model, the second peak in the OSI was observed distal to the stenosis. The distance between the first peak and the second peak was increased as the degree of the stenosis was raised. On the orther hand, the abdominal stenosis model showed a complex oscillatory behavior in the OSI index and did not showed such a strong second peak. As the degree of stenosis was increased, recirculation regions of the both arteries were extended much longer and flow pattern became more complex.

  • PDF

Coronary Artery Disease Reporting and Data System: A Comprehensive Review

  • Parveen Kumar;Mona Bhatia
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.1-24
    • /
    • 2022
  • The Coronary Artery Disease Reporting and Data System (CAD-RADS) is a standardized reporting method for coronary computed tomography angiography (CCTA). It summarizes the findings of CCTA in 6 categories ranging from CAD-RADS 0 (complete absence of coronary artery disease) to CAD-RADS 5 (total occlusion of at least one vessel). It is applied on per patient basis for the highest grade of the stenotic lesion. The CAD-RADS also provides categoryspecific treatment recommendations, helping patient management. The main objectives of the CAD-RADS are to improve the consistency in reporting, facilitate the communication between interpreting and referring clinicians, recommend the best course of patient management, and produce consistent data for quality improvement, research and education. However, CAD-RADS has many limitations, resulting into the misclassification of the observed findings, misinterpretation of the final category, and misguidance for the treatment based upon the single score. In this review, the authors discuss the CAD-RADS categories and modifiers, along with the strengths and limitations of this new classification system.

Amaurosis Fugax Associated with Stenosis of the Intracranial Internal Carotid Artery : Successful Restoration of Ophthalmic Artery Flow by Stent Placement

  • Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.28-30
    • /
    • 2006
  • Two patients presented with amaurosis fugax[AMF]. despite treatment with antiplatelet drugs and anticoagulants due to previous transient ischemic attacks. Angiography demonstrated severe stenosis in the cavernous and petrous internal carotid artery[ICA] respectively, with reduced flow in the ophthalmic artery[OA]. Endovascular stent placement in both patients resulted in normalization of the vessel lumen of the stenotic vessel segments. In addition, complete restoration of OA flow was noted immediately after stenting. Both patients showed no further episode of AMF over a follow-up period of 38 and 23 months respectively. Our clinical and angiographic findings suggest that hemodynamic Insufficiency in retinal vasculature caused by a stenosis of the cavernous or petrous ICA can be treated successfully by endovascular stent.

Single Coronary Artery Associated with Bicupid Aortic Valvular Stenosis -1 Case Report- (이첨 대동맥판막협착을 동반한 단일 관상동맥증 -1례 보고-)

  • 김우찬
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.472-476
    • /
    • 1994
  • The incidence of single coronary artery is extremely rare in a review of congenital anomalies of the coronary arteries. This 27-year-old male patient was referred for the evaluation of cardiac condition showing exertional dyspnea[NYHA class II-III] and chest discomfort for about 1 year. A complete catheterization study including angiogram disclosed large single coronary artery arising from left aortic sinus [Ogden classification L-4] associated with bicuspid aortic valvular stenosis and low grade supravalvular aortic stenosis. Calcified stenotic aortic valve was fully removed with caution and the 19mm St. Jude Medical valve was then implanted in the small nortic annulus. The patient had an uneventful recovery and was discharged on 13th postoperative day.

  • PDF

Onlay Patch Coronary Angioplasty with Autologous Saphenous Vein (자가정맥편을 이용한 관상동맥 혈관성혈술)

  • 류경민;김삼현;박성식;류재옥;서필원
    • Journal of Chest Surgery
    • /
    • v.33 no.6
    • /
    • pp.512-517
    • /
    • 2000
  • Background: Onlay vein patch coronary angioplasty has been known to be an option for coronary artery stenosis in the selective iesions Material and method: During the period between July 1997 and August 1999, coronary angioplasty using autologous saphenous vein was done on 16 sites in 14 cases for the stenotic lesion at the bifurcation area and significantly stenosis distal to anastomosis. Result: Early patency of the angioplasty site was 85.7% at postoperative day 7. There was no statistically difference in graft patency, operative parameters, and complications compared to conventional anatomosis(p>0.05). Conclusion: Despite the small number of cases, the patency rate of the coronary patch angioplasty was comparable to the conventional CABG. Coronary artery only patch angioplasty could be performed in highly selected coronary arteries.

  • PDF

Low Cardiac Output Syndrome Caused by a Coronary Artery Spasm following CABG (관상동맥 우회술 직후에 발생한 자가 혈관의 연축에 의한 저심박출)

  • Kim, Young-Hak;Chung, Yoon-Sang;Kang, Jeong-Ho;Chung, Won-Sang;Shinn, Sung-Ho;Kim, Hyuck
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.633-636
    • /
    • 2007
  • Coronary artery spasm immediately after the coronary artery bypass graft (CABG) surgery is rare but it can cause sudden and severe hypotension or a ventricular arrhythmia. We report a case of low cardiac output syndrome caused by a right coronary artery spasm following CABG that did not show any significant stenotic lesions on preoperative coronary angiography.