• Title/Summary/Keyword: Steinhart

Search Result 4, Processing Time 0.019 seconds

A Design of High Resolution Temperature Measurement System Using Digital Signal Processor (디지털 신호처리기를 이용한 고분해능 온도측정 시스템 설계)

  • Kim, Tae-Hoon;Lim, Ju-Hyun;Kim, Duck-Young;Ko, Han-Woo;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.317-322
    • /
    • 2002
  • This paper presents a linear temperature/voltage relation over a temperature range(0~100$^{\circ}C$) with high-resolution, reasonably god response linearity, reliability, and overall improved performance. A notable feature of the proposed method is that the whole temperature span is divided by 16 subbands thus the variation span of measured voltage is narrowed. Therefore noise characteristic has been improved. The output voltage is amplified after the uniformed DC voltage component is eliminated by offset. We proposed circuit using median value and mean value of digital signal in order to reduce the noise effect. The proposed circuit offers linear temperature/voltage conversion over a wide dynamic range using DSP(TMS320C31) and steinhart equation.

Calibration of Thermistors for Precision Temperature Measurements (정밀온도측정을 위한 서미스터 교정)

  • Gam, Kee-Sool;Kim, Yong-Gyoo;Yang, In-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.329-335
    • /
    • 2011
  • We demonstrated that high-stability thermistors can be calibrated with an uncertainty less than 1 mK, if the error due to the heat conduction is minimized. We first investigated the effect of the self-heating of typical thermistor probes to see how accurate we need to determine the effect of self-heating. We, then, calibrated thermistors and fitted the results using various modeling equations. We found out that the heat conduction is an important factor in achieving the calibration uncertainty under 1 mK for thermistors when the diameter of the probe is as thick as 10 mm. Therefore, we controlled the room temperature within $0.5^{\circ}C$ to minimize the heat conduction error during the calibration. The calibration with an uncertainty below 1 mK was possible when the stabilization time for each calibration was long enough to obtain a good thermal equilibrium.

Au/Titania Composite Nanoparticle Arrays with Controlled Size and Spacing by Organic-Inorganic Nanohybridization in Thin Film Block Copolymer Templates

  • Li, Xue;Fu, Jun;Steinhart, Martin;Kim, Dong-Ha;Knoll, Wolfgang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.6
    • /
    • pp.1015-1020
    • /
    • 2007
  • A simple approach to prepare arrays of Au/TiO2 composite nanoparticles by using Au-loaded block copolymers as templates combined with a sol-gel process is described. The organic-inorganic hybrid films with closely packed inorganic nanodomains in organic matrix are produced by spin coating the mixtures of polystyrene-block-poly(ethylene oxide) (PS-b-PEO)/HAuCl4 solution and sol-gel precursor solution. After removal of the organic matrix with deep UV irradiation, arrays of Au/TiO2 composite nanoparticles with different compositions or particle sizes can be easily produced. Different photoluminescence (PL) emission spectra from an organic-inorganic hybrid film and arrays of Au/TiO2 composite nanoparticles indicate that TiO2 and Au components exist as separate state in the initial hybrid film and form composite nanoparticles after the removal of the block copolymer matrix.

Development of Hardware for the Architecture of A Remote Vital Sign Monitor (무선 체온 모니터기 아키텍처 하드웨어 개발)

  • Jang, Dong-Wook;Jang, Sung-Whan;Jeong, Byoung-Jo;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2549-2558
    • /
    • 2010
  • A Remote Vital Sign Monitor is an in-home healthcare system designed to wirelessly monitor core-body temperature. The Remote Vital Sign Monitor provides accuracy and features which are comparable to hospital equipment while minimizing cost with ease-of-use. It has two parts, a bandage and a monitor. The bandage and the monitor both use the Chipcon2430(CC2430) which contains an integrated 2.4GHz Direct Sequence Spread Spectrum radio. The CC2430 allows Remote Vital Sign Monitor to operate at over a 100-foot indoor radius. A simple user interface allows the user to set an upper temperature and a lower temperature that is monitored with respect to the core-body temperature. If the core-body temperature exceeds the one of two defined temperatures, the alarm will sound. The alarm is powered by a low-voltage audio amplifier circuit which is connected to a speaker. In order to accurately calculate the core-body temperature, the Remote Vital Sign Monitor must utilize an accurate temperature sensing device. The thermistor selected from GE Sensing satisfies the need for a sensitive and accurate temperature reading. The LCD monitor has a screen size that measures 64.5mm long by 16.4mm wide and also contains back light, and this should allow the user to clearly view the monitor from at least 3 feet away in both light and dark situations.