Prediction of Life of Heat Pipes by Measuring Temperature Distribution (온도측정에 의한 히트파이프의 수명예측)

  • Shin, Hung Tae;Polasek, Frantisek;Lee, Yoon Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.856-863
    • /
    • 1999
  • The thermal performance degradation of heat pipes is caused by the non-condensable gas generation mainly due to the electrochemical corrosion which results from the reaction of working fluids with tube materials. In this study, a simplified method described below was proposed to estimate the life of heat pipes concerning the non-condensable gas generation. The temperature distributions at the outer surface of heat pipes was measured, and based on them the amount of non-condensable gas of hydrogen was estimated. Applying it to the Arrhenius model, the mass generation of hydrogen and the volume occupied by the gas In heat pipes could be estimated for an operating temperature and time. Moreover, this simplified method was applied to the accelerated life test of nine methanol-stainless steel heat pipe samples.

Evaluation for fire resistance performance of high strength CFT with loading (재하하중에 따른 고강도 CFT의 내화성능 평가)

  • Hong, Seok-Beom;Yoo, Jo-hyeong;Kim, Woo-Jae;Lee, Ji-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.184-185
    • /
    • 2013
  • Concrete filled steel Tube(CFT) columns have great strength but also fire resistance performance due to the heat storage effect of concrete. In this research, we focus on the fire performance of CFT using 100 MPa concrete without fire protection. We use steel fiber and nylon fiber for fire resistance. We perform the fire test of CFT specimen with loading 200, 300 and 400 ton. To investigate the effect of loading to fire resistance, we compare the fire resistance time according to the loading.

  • PDF

A Study on the Deep Hole Drilling for Refractory Metals - STS type BTA drilling for SKD11 high alloy tool steel (난삭재의 심공가공에 관한 연구 (SKD11고합금공구강에 대한 STS타입 BTA드릴 가공))

  • Sim, Sung-Bo;Kim, Chi-Ok;Kim, Cheol-Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.70-78
    • /
    • 1999
  • 오늘날 기계공업 현장에서 심공드릴가공은 광범위한 응용과 양호한 생산성으로 인하여 그 요구가 증가 되고 있다. 그러므로, 본 연구는 난삭재인 SKD11고합금공구강을 여러가지 절삭조건하에서 BTA드릴가공하여 얻은 실험결과(표면조도, 진직도, 진원도, 원통도, 구멍확대량, 등)를 다루었으며 이들의 이론적 배경과 실험을 비교 분석하였다. 프레스금형 부품과 기계부품으로 사용되고 있는 SKD11고합금공구강은 기계가공이 힘든 난삭재료로서 그 어려움이 크므로 본 연구는 생산현장에 보다 나은 심공드릴가공결과와 관련 지식을 제공 할수 있다고 사료된다.

  • PDF

A constitutive model for confined concrete in composite structures

  • Shi, Qing X.;Rong, Chong;Zhang, Ting
    • Steel and Composite Structures
    • /
    • v.24 no.6
    • /
    • pp.689-695
    • /
    • 2017
  • The constitutive relation is an important factor in analysis of confined concrete in composite structures. In order to propose a constitutive model for nonlinear analysis of confined concrete, lateral restraint mechanism of confined concrete is firstly analyze to study the generalities. As the foundation of the constitutive model, peak stress and peak strain is the first step in research. According to the generalities and the Twin Shear Unified Strength Theory, a novel unified equation for peak stress and peak strain are established. It is well coincident with experimental results. Based on the general constitutive relations and the unified equation for peak stress and peak strain, we propose a unified and convenient constitutive model for confined concrete with fewer material parameters. Two examples involved with steel tube confined concrete and hoop-confined concrete are considered. The proposed constitutive model coincides well with the experimental results. This constitutive model can also be extended for nonlinear analysis to other types of confined concrete.

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Electrochemical corrosion behavior of atmospheric-plasma-sprayed copper as a coating material for deep geological disposal canisters

  • Sung-Wook Kim;Gha-Young Kim;Young-Ho Lee;Jun-Hyuk Jang;Chung-Won Lee;Jeong-Hyun Woo;Seok Yoon
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4032-4038
    • /
    • 2023
  • Cu, which exhibits excellent corrosion resistance in underground environments, has been investigated as a canister material for use in the deep geological disposal of spent nuclear fuels. In this study, the technical viability of atmospheric plasma spraying for producing Cu-coated canisters was investigated. A high-purity Cu film (millimeter scale) was deposited onto a stainless-steel substrate using a plasma gun with a shroud structure. Potentiodynamic polarization studies revealed that the Cu film exhibited a sufficiently low corrosion rate in the groundwater electrolyte. In addition, no pitting corrosion was observed on the Cu film surface after accelerated corrosion studies. A prototype cylindrical Cu film was fabricated on a 1/20 scale on a stainless-steel tube to demonstrate the scalability of atmospheric plasma spraying in producing Cu-coated canisters.

Fabrication of BSCCO Tube by Centrifugal Melting Process (원심 용융 성형법을 이용한 BSCCO 튜브 제조)

  • Kim Ki-Ik;Choi Jung Suk;Oh Sung Young;Jun Byung-Hyuk;Kim H.-R.;Hyun Ok-Bae;Kim Hyoung-Seop;Kim Chan-Joong
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.97-101
    • /
    • 2005
  • Bi-22l2 tubes for fault current limiter (FCL) were fabricated by centrifugal melting process. $SrSO_4$ ($10\;wt.\;\%$) was added to Bi-2212 powder to lower the melting point of Bi-22l2 and to improve the mechanical properties. The BSCCO powder was completely melted at $1300\;^{\circ}C$ using the RF furnace and then poured into rotating steel mold. The steel mold, preheated at $450\;{\circ}C{\sim}550^{\circ}C$ for 2 hour was rotated at $1020{\sim}2520\;RPM$. The solidified BSCCO tube was cooled down to room temperature in the furnace for 48 hours and separated from the mold between Bi-2212 and the mold. $ZrO_2$ solution was used to separate it easily from the mold and Ag tape was attached in the mold inner wall of the mold to analysis electrical property. Bi-22l2 tube was often cracked when the cooling rate was high. BSCCO tubes with $70{\Phi}{\times}100\;mm,\;50{\Phi}{\times}100\;mm$ and $30{\Phi}{\times}150\;mm$ size were fabricated by centrifugal melting process. The $J_{c}s$ of tubes with $50{\Phi}{\times}100\;mm{\times}4.0\;t$ and $50{\Phi}{\times}100\;mm{\times}4.l\;t$ were 178 and $74.2\;A/cm^2$ at 77K, respectively. The processing condition for Bi-2212 tube fabrication was investigated using XRD and SEM analyses.

  • PDF

A study of Experimental on Construction of Concrete Filled in Steel Tube Column under a Low Temperature (저온하에서의 CFT 시공을 위한 실험적 연구)

  • 강용학;이민경;정근호;백민수;김진호;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.489-494
    • /
    • 2002
  • The basic Physical properties, Slump, Slump Flow, Air content, Bleeding, and Settlement of concrete was investigated to test Characteristic of Setting and to evaluate the relation between Model Specimen and Heat of Hydration for construction under Low Temperature (CFT). The objective of this study is to take the partial core after the cementation of Model Specimen, test the compression intensity and analyze the relation to Test Piece.

  • PDF

A Study on Magnetic Abrasive using Sludge

  • Kim, Hee-Nam
    • Journal of the Speleological Society of Korea
    • /
    • no.82
    • /
    • pp.8-12
    • /
    • 2007
  • In this paper, we have investigated the characteristics of the magnetic abrasive using sludge on polishing of internal finishing of seamless stainless steel tube applying magnetic abrasive polishing. Either green carborundum(GC) grain was used to resin sludge at a low temperature, and the sludge of magnetic abrasive powder was synthesized and crushed into 200 meshes. Surface roughness was measured before and after polishing, and more than 38% of improvement of surface roughness was achieved when grain was used under a specific condition. Even though some degree of surface roughness due to deeper scratches still exist, but the result showed a prospective magnetic abrasive polishing using sludge with green carborundum grains.

Adjustable Pulmonary Artery Banding Device (가변형 폐동맥 협착기구의 개발)

  • 김해균;이두연;김동관;이교준;박재희;구경모
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.71-74
    • /
    • 1993
  • For Percutaneous control of the degree of constriction after pulmonary artery banding, we developed an adjustable banding device that was operated by oil pressure. This consists of a stainless steel snare, a polyethylene tube with silicone oil, and a screw adjuster. Five dogs underwent banding of the pulmonary artery or the descending aorta with this device. This band could be effectively and finely adjusted. Although these studies are preliminary, they suggest that a reversible pulmonary artery band can be performed.

  • PDF