• 제목/요약/키워드: Steel-plate reinforcement

검색결과 188건 처리시간 0.022초

Parametric study of energy dissipation mechanisms of hybrid masonry structures

  • Gao, Zhenjia;Nistor, Mihaela;Stanciulescu, Ilinca
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.387-401
    • /
    • 2021
  • This paper provides a methodology to analyze the seismic performance of different component designs in hybrid masonry structures (HMS). HMS, comprised of masonry panels, steel frames and plate connectors is a relatively new structural system with potential applications in high seismic areas. HMS dissipate earthquake energy through yielding in the steel components and damage in the masonry panels. Currently, there are no complete codes to assist with the design of the energy dissipation components of HMS and there have been no computational studies performed to aid in the understanding of the system energy dissipation mechanisms. This paper presents parametric studies based on calibrated computational models to extrapolate the test data to a wider range of connector strengths and more varied reinforcement patterns and reinforcement ratios of the masonry panels. The results of the numerical studies are used to provide a methodology to examine the effect of connector strength and masonry panel design on the energy dissipation in HMS systems. We use as test cases two story structures subjected to cyclic loading due to the availability of experimental data for these configurations. The methodology presented is however general and can be applied to arbitrary panel geometries, and column and story numbers.

중심가새골조의 순단면 파단에 관한 해석적 연구 (Analytical Study of Net Section Fracture in Special Concentrically Braced Frames)

  • 유정한
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • 파괴모드는 저항력과 비탄성 변형 능력의 저하를 일으키는 균열이나 파단으로 귀결된다. 특수중심가새골조의 잠재적 파괴모드는 가새의 균열이나 파단, 가새나 거싯 플레이트의 순단면 파단, 거싯 플레이트용접의 균열, 볼트의 전단균열, 블록전단파단, 그리고 거싯 플레이트의 좌굴 등을 포함하고 있다. HSS 튜브가새는 특수중심가새골조에 자주 사용되고, 가새의 순단면 파단은 거싯 플레이트가 가새로 삽입되는 홈의 끝부분에 가새의 순단면을 통해 발생한다. 이 파괴모드는 인장파괴모드로 분류되고 급격한 강도저하와 취성적인 거동을 보인다. AISC 디자인 규준에선 순단면 보강을 요구하고 있다 (AISC 2001). 이 논문에서, 순단면 보강의 필요성에 대해 논의한다. 먼저, 미국 버클리대학교에서 수행됐던 순단면 파단실험을 유한요소모델을 이용한 이 실험의 모델링을 통해 소개한다. 실제 골조에서의 순단면 파단의 가능성을 조사하기 위해, 홈이 있는 중심가새골조를 유한요소법을 이용 모델링 하고, 인장지배의 근거리지진 이력을 적용시킨다. 이는 이력이 순단면 파단의 가장 중요한 인자라는 이전 해석 결과에서 기인한 것이다. 순단면 보강의 필요성과 인장지배의 근거리지진 이력의 영향에 대해 조사한다.

The use of ferrocement in the construction of squat grain silos

  • Topcuoglu, Kivanc;Unal, Halil Baki
    • Computers and Concrete
    • /
    • 제18권1호
    • /
    • pp.53-68
    • /
    • 2016
  • In this study, an investigation is made from the statics and economic aspects of the possibility of using the composite material ferrocement on the surfaces of squat cylindrical grain silos. For this purpose, the geometry of two model silos, each of height 5 m and diameter 5 m and 12.5 m, was designed. Five different reinforced plates of 10 and 20 mm thickness were produced to research the most suitable ferrocement plates to be used on the surface of these silos. Most durable reinforcement type for covering the silo surface was determined by pressure and bending tests. Grade 30 and Grade 55 steel plates were also considered for use in covering steel-coated silos. In the statics analysis performed with SAP2000, the least plate thicknesses needed for silos surfaced with Grade 30 and Grade 55 steel were found to be 6.20 mm and 4.70 mm respectively for silos of diameter 5 m, and 6.70 mm and 5.00 mm for silos of diameter 12.5 m. In the economic analysis, it was found that 20 mm thick Type 4 (with a wire diameter of 0.30 mm and a mesh aperture of $2mm{\times}2mm$ square type) reinforced ferrocement surfacing material was 5.6-6.1 times more economical than Grade 30 steel surfacing material and 4.4-4.7 times more economical than using Grade 55 steel. These results show that ferrocement can be used in place of steel from the point of view both of statics and economy.

Static and dynamic behavior of (FG-CNT) reinforced porous sandwich plate using energy principle

  • Medani, Mohammed;Benahmed, Abdelillah;Zidour, Mohamed;Heireche, Houari;Tounsi, Abdelouahed;Bousahla, Abdelmoumen Anis;Tounsi, Abdeldjebbar;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • 제32권5호
    • /
    • pp.595-610
    • /
    • 2019
  • This paper deals with the static and dynamic behavior of Functionally Graded Carbon Nanotubes (FG-CNT)-reinforced porous sandwich (PMPV) polymer plate. The model of nanocomposite plate is investigated within the first order shear deformation theory (FSDT). Two types of porous sandwich plates are supposed (sandwich with face sheets reinforced / homogeneous core and sandwich with homogeneous face sheets / reinforced core). Functionally graded Carbon Nanotubes (FG-CNT) and uniformly Carbon Nanotubes (UD-CNT) distributions of face sheets or core porous plates with uniaxially aligned single-walled carbon nanotubes are considered. The governing equations are derived by using Hamilton's principle. The solution for bending and vibration of such type's porous plates are obtained. The detailed mathematical derivations are provided and the solutions are compared to some cases in the literature. The effect of the several parameters of reinforced sandwich porous plates such as aspect ratios, volume fraction, types of reinforcement, number of modes and thickness of plate on the bending and vibration analyses are studied and discussed. On the question of porosity, this study found that there is a great influence of their variation on the static and vibration of porous sandwich plate.

긴급시공이 가능한 FRP 내진보강재 개발 및 최적 보강량 산정을 위한 해석적 연구 (Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction)

  • 김진섭;권민호;서현수;임정희;김동영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.136-145
    • /
    • 2013
  • 최근 발생한 대규모 지진으로 구조물의 내진보강에 대한 사회적 관심도가 높아지고 있다. 특히 내진 설계가 반영되지 않은 기둥은 취성적인 파괴로 구조물 전체붕괴를 유발하기 때문에 내진보강이 적용 되어야한다. 과거에는 단면증설법, 강판보강법등이 주로 적용되었고 최근에는 복합재료의 장점을 이용한 섬유보강법이 선호되고 있다. 그러나 이러한 보강법들은 구조물의 물리적 손상을 유발하며, 작업공간과 시간소비가 크다는 단점이 있다. 본 연구에서는 기존 보강법의 단점을 보강하여 복합재료 (Fiber reinforced polymer)와 Aluminum 체결부 이용한 FRP 내진보강재를 개발하였다. 비선형 유한요소 해석프로그램을 통해 개발된 FRP 내진보강재의 최적 보강량을 결정하였다.

토목섬유를 이용한 보강토옹벽의 개발 (A Study on the Development of Reinforced Earth wall by Geotextile)

  • 도덕현;유능환
    • 한국농공학회지
    • /
    • 제28권2호
    • /
    • pp.63-73
    • /
    • 1986
  • The model was developed by applying the principles of Bacot and Vidal to measure the behavior of deformation of the reinforced earth wall, and various tasts were performed by using the plastic fabric filter and the galvanized steel plate as a strip. The results obtained are as follows; 1. When the reinforced earth wall is deformed by the load, the strip is completely reinforced by the backfill materials and changed to the rigid block state, under the state of failure which permits sliding only, the next theoretical equation is formed. (H/L) . tan$\theta$ [cosO-sinOtanO] =2sinO[tan($\theta$ +0) +tanO] 2.The degree of the mutual reinforcement of the backfill material and the strip depend on the physical characteristics of the each material especially the angle of shearing resistance of the backfill material is desirable over 20$^{\circ}$ and, if it is over 400, its function could be a maximum. 3.The distribution of the maximum tensile strain of the reinforcement is changing with the height of reinforced earth wall, and when the height from bottom of the reinforced earth wall is 1.85 to 3. 35m, the maximum tensile strain appears at 2m from the skin element. The maximum tensile strain is increased by the depth of the reinforced earth wall from surface, and increased with the lapse of time after construction. 4.The failure surface of the reinforced earth wall by the concrete skin was about 60$^{\circ}$and the failure behavior of the reinforced earth wall in which the fabric filter was buried was slow, and so the pore pressure could be decreased. 5.It is possible to construct the fabric retained earth wall by the plastic fabric filter only. And the reinforcing effect between the steel plate and the plastic fabric filter is not largely different. however, in the aspect of the economic durability, the plastic fabric filter is more advantageous. 6.The reinforcing action mainly depends on the width and the length of the reinforcing materials, if possible, the full width is advantageous to enlarge the contact area with backfill. but considering the economic aspect, it is neccessary to develop the method controlling the space of the strip.

  • PDF

반복하중을 받는 하이브리드 프리캐스트 보-기둥 접합부의 성능평가 (Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading)

  • 최현기;유창희;최윤철;최창식
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.325-333
    • /
    • 2010
  • 이 연구에서는 시공성과 경제성이 향상되고 중진 지역에서 사용할 수 있는 새로운 프리캐스트 콘크리트 보-기둥 접합부 상세를 복합구조로 개발하고 실험을 통하여 이를 검증하였다. 이 상세는 기둥 속에 매립된 각형강관과 보U형 단부를 갖는 보 단부에 매립된 플레이트를 볼트로 결합시킬 수 있는 구조로 되어있다. 하이브리드 스틸-콘크리트 접합합부에 앞서 콘크리트가 조기에 파괴되는 것을 막기 위하여 접합부 부분에 ECC(engineered cementitious composite)를 사용하였다. 개발된 접합부 상세에 대한 성능을 검증하기 위하여 보-기둥 접합부 실험체를 계획하여 이에 대한 내진성능 실험을 실시하였다. 내부 접합부에 있어서는 접합부 횡보강근 유무와 현장타성 범위를 변수로 3개의 실험체를 제작하였다. 실험은 기둥에 일정 축력을 가한 상태에서 PC기둥 단부에 액츄에이터를 설치하여 변위제어로써 반복가력 하여 실시하였다. 실험에서 얻은 자료를 접합부 내력, 강성, 에너지 소산능력 등에 대하여 분석하였으며, 그 결과 이 연구에서 제시한 새로운 보-기둥 접합부 상세는 강재와 콘크리트 그리고 ECC 사이에서의 다른 부착 특성 때문에 구조거동에서 차이점이 관찰되었으며, 기준 실험체를 제외한 두 실험체의 경우 ECC 및 철골연결재에 의해 소성힌지를 유도할 수 있는 것으로 나타났다. 그리고 프리캐스트 접합부는 높은 일체성과 모멘트 저항 능력을 보이며 중진 지역에서 사용가능함을 보였다.

Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams

  • Qi, Jingjing;Xie, Zuwei;Cao, Hua;Huang, Zhi;Lv, Weirong;Shi, Weihua
    • Structural Engineering and Mechanics
    • /
    • 제83권6호
    • /
    • pp.789-798
    • /
    • 2022
  • The stud shear connector is the main force transfer member in the steel-concrete composite member, and the mechanical behavior is very complicated in the concrete. The concrete around the stud is subjected to the pry-out local pressure concentration of the stud, which can easily produce splitting mirco-cracks. In order to solve the problem of pry-out local splitting of stud shear connector, a kind of stud shear connector with constraint measure is proposed in this paper. Through the push-out test, the interface shear behavior of the new stud shear connector between steel and concrete flange plate was studied, and the difference between the new stud shear connector and the traditional stud connector was compared. The results show that the stud shear connector with constraint measure can effectively avoid the adverse effect of local pressure splitting by relying on its own constraint measure. The shear stiffness of the interface between steel and concrete flange plates is greatly improved, which provides a theoretical basis for the design of strong connection coefficient of steel-concrete composite structures.

U-플랜지 트러스 보의 구조 내력에 관한 실험 연구 (Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam)

  • 오명호;김영호;강재윤;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.113-121
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.

외부 후 긴장된 무도상 철도 판형교 동적 거동 (Dynamic Behavior of External Post-tensioned Non-ballast Steel Plate Girder Railway Bridge)

  • 박용걸;박영훈;최동호
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.315-322
    • /
    • 2008
  • 본 연구에서는 외부 후 긴장 보강 공법을 공용중인 무도상 철도 판형교 보강 방안으로서 적용 할 경우 긴장재 강성 및 도입 긴장력의 크기가 동적 거동 특성 변화에 미치는 영향을 실험 및 해석적으로 평가 하였다. 연구 결과 긴장재 강성에 의해 고유 진동수가 증가하나 긴장력 크기 증가에 의한 고유 진동수 감소에 의해 필요 긴장력 도입시 최종적으로 고유 진동수가 미소하게 감소하는 것으로 나타났으며, 외부 후 긴장력과 고유 진동수 변화 양상에 대한 명확한 관계 정립을 위한 추가적인 연구가 필요한 것으로 나타났다. 또한, 외부 후 긴장에 의해 동적 처짐, 동적 휨 응력 및 중력 방향 가속도가 감소하는 것으로 나타났다. 한편, 외부 후 긴장에 의하여 중력 방향 가속도의 70% 수준인 횡 방향 가속도가 최대 20% 정도 증가하는 것으로 나타나 이에 대한 추가적인 연구가 필요한 것으로 판단된다.