• 제목/요약/키워드: Steel-plate

검색결과 2,892건 처리시간 0.025초

Behavior of fully- connected and partially-connected multi-story steel plate shear wall structures

  • Azarafrooza, A.;Shekastehband, B.
    • Structural Engineering and Mechanics
    • /
    • 제76권3호
    • /
    • pp.311-324
    • /
    • 2020
  • Until now, a comparative study on fully and partially-connected steel shear walls leading to enhancing strength and stiffness reduction of partially-connected steel plate shear wall structures has not been reported. In this paper a number of 4-story and 8-story steel plate shear walls, are considered with three different connection details of infill plate to surrounding frame. The specimens are modeled using nonlinear finite element method verified excellently with the experimental results and analyzed under monotonic loading. A comparison between initial stiffness and shear strength of models as well as percentage of shear force by model boundary frame and infill plate are performed. Moreover, a comparison between energy dissipation, ductility factor and distribution of Von-Mises stresses of models are presented. According to the results, the initial stiffness, shear resistance, energy dissipation and ductility of the models with beam-only connected infill plates (SSW-BO) is found to be about 53%, 12%, 15% and 48% on average smaller than those of models with fully-connected infill plates (SPSW), respectively. However, performance characteristics of semi-supported steel shear walls (SSSW) containing secondary columns by simultaneously decreasing boundary frame strength and increasing thickness of infill plates are comparable to those of SPSWs. Results show that by using secondary columns as well as increasing thickness of infill plates, the stress demands on boundary frame decreases substantially by as much as 35%. A significant increase in infill plate share on shear capacity by as much as 95% and 72% progress for the 4-story SSW-BO and 8-story SSSW8, respectively, as compared with non-strengthened counterparts. A similar trend is achieved by strengthening secondary columns of 4-story SSSW leading to an increase of 50% in shear force contribution of infill plate.

Composite deck construction for the rehabilitation of motorway bridges

  • Greiner, R.;Ofner, R.;Unterweger, H.
    • Steel and Composite Structures
    • /
    • 제2권1호
    • /
    • pp.67-84
    • /
    • 2002
  • Traffic decks of steel or composite motorway bridges sometimes provide the opportunity of using the composite action between an existing steel deck and a reinforced concrete plate (RC plate) in the process of rehabilitation, i.e., to increase the load-carrying capacity of the deck for concentrated traffic loads. The steel decks may be orthotropic decks or also unstiffened steel plates, which during the rehabilitation are connected with the RC plate by shear studs, such developing an improved local load distribution by the joint behaviour of the two plate elements. Investigations carried out, both experimentally and numerically, were performed in order to quantitatively assess the combined static behaviour and to qualitatively verify the usability of the structure for dynamic loading. The paper reports on the testing, the numerical simulation as well as the comparison of the results. Conclusions drawn for practical design indicated that the static behaviour of these structures may be very efficient and can also be analysed numerically. Further, the results gave evidence of a highly robust behaviour under fatigue equivalent cyclic traffic loading.

Seismic Behavior Investigation of the Corrugated Steel Shear Walls Considering Variations of Corrugation Geometrical Characteristics

  • Farzampour, Alireza;Mansouri, Iman;Hu, Jong Wan
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1297-1305
    • /
    • 2018
  • The corrugated steel plate shear walls have recently been proposed to address the seismic issues associated with simple steel plate shear walls; however, stiffness, strength, and ductility of the corrugated shear walls are significantly affected by varying the corrugation geometry under seismic loading. The present study investigates steel shear walls' models with corrugated or simple infill plates subjected to monotonic and cyclic loads. The performance of the corrugated steel plate is evaluated and then compared to that of the simple steel plates by evaluating the damping ratios and energy dissipation capability. The effect of corrugation profile angle, the existence of an opening, and the corrugation subpanel length are numerically investigated after validation of the finite element modeling methodology. The results demonstrate that incorporating corrugated plates would lead to better seismic damping ratios, specifically in the case of opening existence inside of the infill plate. Specifically, the corrugation angle of $30^{\circ}$ decreases the ultimate strength, while increasing the initial stiffness and ductility. In addition, the subpanel length of 100 mm is found to be able to improve the overall performance of shear wall by providing each subpanel appropriate support for the adjacent subpanel, leading to a sufficient buckling resistance performance.

Evaluation of unilateral buckling of steel plates in composite concrete-steel shear walls

  • Shamsedin Hashemi;Samaneh Ramezani
    • Structural Engineering and Mechanics
    • /
    • 제88권2호
    • /
    • pp.129-140
    • /
    • 2023
  • To increase the stiffness and strength of a reinforced concrete shear wall, steel plates are bolted to the sides of the wall. The general behavior of a composite concrete-steel shear wall is dependent on the buckling of the steel plates that should be prevented. In this paper, the unilateral buckling of steel plates of a composite shear wall is studied using the Rayleigh-Ritz method. To model the unilateral buckling of steel plate, the restraining concrete wall is described as an elastic foundation with high stiffness in compression and zero stiffness in tension. To consider the effect of bolt connections on the plate's buckling, a constrained optimization problem is solved by using Lagrange multipliers method. This process is used to obtain the critical elastic local buckling coefficients of unilaterally-restrained steel plates with various numbers of bolts, subjected to pure compression, bending and shear loading, and the interaction between them. Using these results, the spacing between shear bolts in composite steel plate shear walls is estimated and compared with the results of the AISC seismic provisions (2016). The results show that the AISC seismic provisions(2016) are overly conservative in obtaining the spacing between shear bolts.

Three-dimensional finite element analysis of reinforced concrete slabs strengthened with epoxy-bonded steel plates

  • Metwally, Ibrahim M.
    • Advances in concrete construction
    • /
    • 제2권2호
    • /
    • pp.91-108
    • /
    • 2014
  • This paper presents a nonlinear finite element analysis (FEA) in order to investigate the flexural performance of one-way slabs strengthened by epoxy-bonded steel plates. Four point loading scheme is selectively chosen. A model is developed to implement the material constitutive relationships and non-linearity. Five Slabs were modeled in FEM software using ABAQUS. One slab was unstrengthened control slab and the others were strengthened with steel plates with varying the plate thickness and configuration. In order to verify the accuracy of the numerical model, a comparison was done between the experimental results available in the literature and the proposed equations by ACI 318-11 for the calculation of ultimate load capacities of strengthened slabs, the agreement has proven to be good and FEA attained accurate results compared with ACI code. A parametric study was also carried out to investigate the influence of thickness of steel plate, strength of epoxy layer and type of strengthening plate on the performance of plated slabs. Also, the practical and technical feasibility of splitting the steel plate in strengthening process has been taken into account. For practical use, the author recommended to use bonded steel plate as one unit rather than splitting it to parts, because this saves more effort and reduces the risk of execution errors as in the case of multiple bonded parts. Both techniques have nearly the same effect upon the performance of strengthened slabs.

Evaluation of cyclic behavior of lateral load resisting system with eccentric brace and steel plate

  • Reza Khalili Sarbangoli;Ahmad Maleki;Ramin K. Badri
    • Structural Engineering and Mechanics
    • /
    • 제89권3호
    • /
    • pp.239-252
    • /
    • 2024
  • Steel plate shear walls (SPSWs) are classified as lateral load-resisting systems. The feasibility of openings in the steel plate is a characteristic of SPSWs. The use of openings in SPSWs can lower the load capacity, stiffness, and energy dissipation. This study proposes a novel form of SPSWs that provides convenient access through openings by combining steel plates and eccentrically braced frames (EBFs). The proposed system also avoids a substantial reduction in the strength and stiffness. Hence, various geometric forms were analyzed through two different structural approaches. Groups 1, 2, and 3 included a steel EBF with a steel plate between the column and EBF in order to improve system performance. In Group 4, the proposed system was evaluated within an SPSW with openings and an EBF on the opening edge. To evaluate the performance of the proposed systems, the nonlinear finite element method (NL-FEM) was employed under cyclic loading. The hysteresis (load-drift) curve, stress contour, stiffness, and damping were evaluated as the structural outputs. The numerical models indicated that local buckling within the middle plate-EBF connection prevented a diagonal tension field. Moreover, in group 4, the EBF and stiffeners on the opening edge enhanced the structural response by approximately 7.5% in comparison with the base SPSW system.

선상 가열을 위한 가스 토치와 강판 사이의 열유동 해석 (Analysis of the thermal fluid flow between the gas torch and the steel plate for the application of the line heating)

  • 우종훈;신종계
    • 대한조선학회논문집
    • /
    • 제39권2호
    • /
    • pp.52-60
    • /
    • 2002
  • 선상가열은 고온의 열원을 강판에 가하여 잔류변형을 얻음으로써 곡면을 성형하는 과정이다. 잔류 변형 제어를 위해서 열원과 강판 사이의 열전달 현상 및 강판의 온도 분포에 대한 이해가 필요하다. 본 연구는 가스 토오치로부터 분출된 연소 불꽃에 의한 가스가 강판을 가열하는 선상 가열 과정을 고온, 고속의 충돌 분출류와 그에 의한 열 대류 전달 현상으로 간략화 하여 강판의 온도 분포에 대한 해석을 시도하였다. 해석을 위하여 토오치에서의 연소 현상을 고온, 고속의 충돌 분출 현상으로 간략화 시키고 난류열 유동 해석을 수행하였다. 난류 열 유동 해석을 통하여 토오치와 강판 사이의 온도장 분포를 계산하였고 충돌 분출류에 관한 근사 누설트 실험식을 이용하여 분출류와 강판 사이의 열 대류 계수를 계산하였다. 온도 분포와 열 대류 계수를 통해서 강판에 유입되는 열 유속을 계산할 수 있었고 열 유속을 표면력으로 하는 열 전도 전달 해석을 통해 강판 내의 온도장 분포를 구할 수 있었다. 난류 열 유동 해석 및 전도 열 전달 해석을 위하여 유한 요소법을 이용하였으며, 유한 요소 해석결과를 실험 결과와 비교함으로써 본 연구에서 수행한 해석 과정의 타당성에 대한 검증을 수행하였다.

주기하중을 받는 골조강판벽의 실험연구 (Framed Steel Plate Wall subject to Cyclic Lateral Load)

  • 박홍근;곽재혁;전상우;김원기
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.781-792
    • /
    • 2004
  • 스티프너가 없는 얇은 강판을 사용한 골조강판벽 시스템에 대한 실험연구를 실시하였다. 1경간 3층의 골조강판벽에 주기횡하중을 재하하였으며, 주요한 실험 변수는 강판의 두께, 기둥의 강도이다. 실험결과를 이용하여 강판벽의 강도, 변형능력, 에너지 소산능력을 연구하였으며, 이를 토대로 골조강판벽의 파괴메카니즘을 분석하였다. 실험결과, 얇은 강판을 사용하는 골조강판벽은, 높은 강도, 낮은 연성능력, 캔틸레버거동특성을 나타내는 일반적인 가새골조나 스티프너 보강된 강판벽과는 여러 면에서 다른 거동특성을 나타낸다. 골조강판벽에서는 강판의 조기국부좌굴과 인장응력장 작용이 발생하면서, 전 층에 고르게 항복변형이 분포된다. 이로 인하여 변형형태는 휨변형과 전단변형의 복합형태를 나타내며, 우수한 강도 및 에너지 소산능력과 연성모멘트 골조에 버금가는 변형능력을 나타내었다. 그러나 일반적인 가새골조와는 달리 보, 기둥 등의 골조부재는 강판의 인장응력장을 지지할 수 있도록 설계되어야 하며, 따라서 기둥의 강도가 작고 콤팩트 단면을 사용하지 않은 경우에는 약층현상이 발생하며 강도가 급격히 저하되었다. 얇은 강판을 사용하는 골조강판벽은 일반적인 가새골조나 스티프너 보강 강판벽과는 차별되는 우수한 변형능력을 갖고 있으므로 연성내진구조시스템으로 활용할 수 있다.

Inelastic buckling and post-buckling behavior of gusset plate connections

  • Hadianfard, Mohammad Ali;Khakzad, Ali Reza
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.411-427
    • /
    • 2016
  • In this study, by using finite element non-linear static analysis and comparing it with experimental models, the buckling and post-buckling behavior of bracing gusset plates has been investigated. The effects of such parameters as dimension and thickness of the gusset plate and the influence of position of the bracing member on the behavior of gusset plate have been examined. The results of the analyses clearly suggest that capacity, buckling and post-buckling behaviors of gusset plates depend on the position of the bracing splice plate with respect to the free bending line as well as on the size and thickness of the gusset plate. Also, with respect to numerical analysis results, some practical graphs for the calculation of buckling capacity of gusset plate connections are presented. For steel structures, the proposed method is apparently more accurate than available code procedures.

프리스트레스된 압연강재보(H-BEAM)의 휨 거동에 대한 실험적 연구 (A Experimental Study on Bending Behaviors of Prestressed Hot-rolled H-Beam)

  • 임성순;정찬핵
    • 한국강구조학회 논문집
    • /
    • 제18권2호
    • /
    • pp.239-250
    • /
    • 2006
  • 본 연구는 H형 압연강재보에 강종이 다른 강재보 또는 강판을 부착하여 프리스트레스를 도입한 강재보의 휨 거동에 대한 실물실험결과를 비교 분석하였다. 또한 이론적인 해석과의 비교를 통하여 구조적인 성능을 검증하였다. 두 개의 부재를 결합하여 합성부재로 만드는데 있어서 결합시 부재간 서로 이완된 느슨한 상태에서 결합이 되기 때문에 하중이 증가함에 따라 부재간에 하중의 재분배가 일어나 그 구조적인 성능을 제대로 발휘하지 못한다. 따라서 두 부재를 합성시킬 때에는 프리스트레스를 가하여 접합해야 한다. 실험결과로부터 강재보에 추가로 강재보 또는 강판을 붙여 프리스트레스가 도입된 강재보는 강성증가와 프리스트레스에 의한 내하력 증가효과가 뚜렷함을 알 수 있었다.