• 제목/요약/키워드: Steel truss structure

검색결과 141건 처리시간 0.028초

온도변화에 자유로운 임피던스 기반 국부 손상검색 (Temperature Effect-free Impedance-based Local Damage Detection)

  • 구기영;박승희;이종재;윤정방
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.21-26
    • /
    • 2007
  • This paper presents an impedance-based structural health monitoring (SHM) technique considering temperature effects. The temperature variation results in a significant impedance variation, particularly both horizontal and vertical shifts in the frequency domain, which may lead to erroneous diagnostic results of real structures. A new damage detection strategy has been proposed based on the correlation coefficient (CC) between the reference impedance data and a concurrent impedance data with an effective frequency shift which is defined as the shift causing the maximum correlation. The proposed technique was applied to a lab-sized steel truss bridge member under the temperature varying environment. From an experimental study, it has been demonstrated that a narrow cut inflicted artificially to the steel structure was successfully detected using the proposed SHM strategy.

  • PDF

복부 파형강판을 사용한 PSC 복합 교량의 비틀림 해석모델의 제안 및 변수해석 (A Development of Torsional Analysis Model and Parametric Study for PSC Box Girder Bridge with Corrugated Steel Web)

  • 이한구;김광수
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.281-288
    • /
    • 2008
  • 콘크리트와 강재의 특성을 살린 복합구조 교량에 있어서 새로운 구조 형식인 복부 파형강판 PSC 박스거더 교량은 시공성 및 경제적인 측면에서 우수한 장점이 있다. 그러나 이와 관련된 기존 연구는 전단 좌굴에 대한 복부 파형강판의 거동 및 접합부의 형상 개발과 관련하여 한정된 측면이 있으며, 교량 자체로서의 비틀림 거동에 대한 연구는 다소 부족한 실정으로 합리적인 비틀림 해석모델의 개발과 거동 예측에 대한 연구가 필요하다고 판단된다. 본 연구에서는 복부 파형강판 PSC 박스거더 교량에 대하여, 공간트러스 모델을 이용한 Rausch의 제안식과 RC 요소의 연화효과가 고려된 평형 방정식, 적합 조건식을 활용하고 복부 파형강판 구조 형태에 의하여 추가적으로 고려해야 할 구성 방정식과 모델, 제안식 등을 적용한 비틀림 해석모델을 제시하고 기존에 수행된 부재 실험결과와의 비교를 통하여 해석모델의 합리성을 검토하였다. 또한 복부 파형강판 PSC 박스의 비틀림 거동에 영향을 미치는 프리스트레싱 힘과 콘크리트 압축강도를 변수로 한 해석을 진행하였으며, 제안된 비틀림 해석모델을 이용하여 복부 파형 강판과 프리스트레스 된 콘크리트 부재의 단면 형상비(H/B)에 따른 해석을 수행하여 보다 합리적인 비틀림 정수와 이와 관련한 수정식을 제안하였다.

Analysis of a damaged industrial hall subjected to the effects of fire

  • Kmet, Stanislav;Tomko, Michal;Demjan, Ivo;Pesek, Ladislav;Priganc, Sergej
    • Structural Engineering and Mechanics
    • /
    • 제58권5호
    • /
    • pp.757-781
    • /
    • 2016
  • The results of diagnostics and analysis of an industrial hall located on the premises of a thermal power plant severely damaged by fire are presented in the paper. The comprehensive failure-related diagnostics, non-destructive and destructive tests of steel and concrete materials, geodetic surveying of selected structural members, numerical modelling, static analysis and reliability assessment were focused on two basic goals: The determination of the current technical condition of the load bearing structure and the assessment of its post fire resistance as well as assessing the degree of damage and subsequent design of reconstruction measures and arrangements which would enable the safe and reliable use of the building. The current mechanical properties of the steel material obtained from the tests and measured geometric characteristics of the structural members with imperfections were employed in finite element models to study the post-fire behaviour of the structure. In order to compare the behaviour of the numerically modelled steel roof truss, subjected to the effects of fire, with the real post-fire response of the damaged structure theoretically obtained resistance, critical temperature and the time at which the structure no longer meets the required reliability criteria under its given loading are compared with real values. A very good agreement between the simulated results and real characteristics of the structure after the fire was observed.

Tuned mass dampers for human-induced vibration control of the Expo Culture Centre at the World Expo 2010 in Shanghai, China

  • Lu, Xilin;Ding, Kun;Shi, Weixing;Weng, Dagen
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.607-621
    • /
    • 2012
  • The Expo Culture Centre is one of the permanent buildings at the World Expo 2010 in Shanghai, China. The main structure has an oval shape and consists of 36 radial cantilever steel trusses with different lengths and inner frames made of concrete-filled rectangular steel tube members. Tuned mass dampers are used to reduce the excessive vibrations of the sixth floor that are caused by human-induced resonance. A three-dimensional analytical model of the system is developed, and its main characteristics are established. A series of field tests are performed on the structure, and the test results show that the vertical vibration frequencies of most structural cantilevers are between 2.5 Hz and 3.5 Hz, which falls in the range of human-induced vibration. Twelve pairs of tuned mass dampers weighing 115 tons total were installed in the structure to suppress the vibration response of the system. These mass dampers were tuned to the vertical vibration frequency of the structure, which had the highest possibility of excitation. Test data obtained after the installation of the tuned mass dampers are used to evaluate their effectiveness for the reduction of the vibration acceleration. An analytical model of the structure is calibrated according to the measured dynamic characteristics. An analysis of the modified model is performed and the results show that when people walk normally, the structural vibration was low and the tuned mass dampers have no effect, but when people run at the structural vibration frequency, the tuned mass dampers can reduce the floor vibration acceleration by approximately 15%.

주기하중을 받는 세장한 이중강판합성벽의 비선형해석 (Nonlinear Analysis of Slender Double Skin Composite Walls Subjected to Cyclic Loading)

  • 엄태성;박홍근
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.505-517
    • /
    • 2008
  • 휨지배 거동을 나타내는 세장한 이중강판합성벽의 비탄성 거동을 예측하기 위하여 비선형 수치해석 모델이 연구되었다. 수치해석의 편리를 위하여, 제안된 모델은 비교적 단순한 모델을 가지고 비탄성 거동을 근사적으로 예측할 수 있는 거시적 모델로 개발되었다. 휨지배 거동을 나타내는 벽체에 대해서는 다중평행요소 모델이 사용되었으며, 깊은 연결보의 전단거동을 위하여 X형 대각요소 모델이 사용되었다. 각 요소의 주기거동을 예측하기 위하여 콘크리트 및 강판 요소에 대한 간략화된 일축의 주기모델을 제안하였다. 제안된 해석모델은 1자형 및 T형 단일벽과 병렬벽에 적용하였으며, 그 결과는 기존의 실험결과와 비교되었다.

강철도교 바닥판 세로보 절취부의 피로균열 진전해석 (Fatigue Crack Propagation in Coped Stringers of Steel Railway Bridges)

  • 최동호;안우성;최항용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.557-562
    • /
    • 2003
  • The responses of the floor system of a railway bridge are investigated for fatigue life prediction of damaged members using fracture mechanics approach. Numerical analysis of the structure is performed in order to see the influence of track-structure interaction and continuity of the truss connection on the response of the bridge members. Fatigue crack growth analysis is carried through equivalent stress obtained from time-history analysis. The results of time-history analysis agree with measured responses. The fatigue propagation life increases as the curvature in the coped stringer increases.

  • PDF

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • 국제초고층학회논문집
    • /
    • 제3권3호
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.

알루미늄 압출재를 사용한 철도차량차체의 단위 압출재 최적설계 (An Optimal Design for Truss Core Unit of Railway Carbody of Aluminum Extrusion Plate)

  • 장창두;하윤석;조영천;신광복
    • 한국철도학회논문집
    • /
    • 제6권3호
    • /
    • pp.194-202
    • /
    • 2003
  • To make railway carbody light in weight has advantages at some aspects of both manufacturing and maintenance. Recently, railway carbodys of steel structure have been lightened their weight by using aluminum extrusion plate. for the additional lightening of railway carbody, an optimal design which maintains proper strength and minimizes weight must be achieved. Optimization which is used with finite element analysis for aluminum extrusion plate has the disadvantage of consuming much time. In this paper, the method of equivalent material property which is available to FEA code is established using the method of equivalent stiffness. This method for plate is expanded into the method for railway carbody structure with plates and shells. An objective function is established for maximum stiffness of unit aluminum extrusion plate using established method of equivalent material property. We performed an multi-objective optimization using the penalty function method. As a result, recommendable shapes and sizes of unit extrusion plate for under-frame of high speed train is presented.

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가 (Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame)

  • 송진희;이동윤;신동일;전현도;박철용;김상균
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.