• 제목/요약/키워드: Steel Base Plate

검색결과 160건 처리시간 0.019초

조선용 고장력강재와 보통강도강재간의 용접부위의 부식피로와 전기방식에 관한 연구 (A study on the corrosion fatigue and cathodic protection of the welded zone between high tensile strength steel and general strength steel used for the shipbuilding)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.39-50
    • /
    • 1984
  • The plane bending corrosion fatigue test was performed on the welded zone between SM58 steel plate and SM41 steel plate jointed with submerged arc welding in the air and in the natural sea water with various conditions. The main results obtained from the test are summarized as follows: 1) The welded zone of the steel plates has the lowest impact strength and the highest electrode potential, but the hardness was mediate of SM58 base and SM41 base. 2) The cathodic protection of the welded zone was also effective for the plane bending corrosion fatigue, and the optimum protection potential of the welded zone was -1,000 mV SCE. 3) The corrosion fatigue strength under the various stress conditions of the steel plate could be estimated and also the require safety factors on the design could be obtained from the plane bending fatigue limit diagram.

  • PDF

Base Plate로 보강된 기둥-기초 접합부의 뚫림전단강도 연구 (A Study on Punching Shear of Column-Foundation Joint Connection for Reinforced Steel Base Plate)

  • 김성겸;박종권;한상희;김병철;장일영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 2015
  • 본 논문에서는 RC 기둥-기초 접합부분을 중공형 및 확장형 강재 Base Plate로 보강한 실험체에 대한 하중 재하 실험을 실시하여, 강재 Base Plate가 부착된 RC 기둥-기초에서의 뚫림전단에 대한 보강효과를 정량화 하기 위한 구조해석 및 기초적 실험 연구를 수행하였다. 실험은 각 실험체별 부착된 Base Plate의 두께, 내민길이, 치수, 형식 등의 변수에 따라 수행하였으며 실험을 통하여 응력분산에 적합한 적정 Base Plate의 모양 및 치수를 확인하였고, 보강효과에 대하여 분석하였다. 실험을 통해 Base Plate가 기초에 전해지는 수직하중의 응력분산에 효과적이었으며 폐쇄형보다 중공형 보강이 효율적인 것을 확인하였다. 보강을 통해 변위연성 능력의 향상으로 기존의 기초두께보다 두께가 감소한 실험체에서도 기존보다 높은 성능을 나타냈다. 보강 후의 실험체로부터 구조물의 거동특성을 취성으로부터 연성으로 유도 할 수 있었으며, 실험체를 파괴시까지 가력함으로써 파괴시 보강 전, 후에 대한 균열 및 파괴양상을 확인 하였다.

Exposed Reinforced Concrete-Filled Steel Tubular (RCFST) column-base joint with high-strength

  • Mou, Ben;Wang, Zian;Qiao, Qiyun;Zhou, Wanqiu
    • Steel and Composite Structures
    • /
    • 제44권1호
    • /
    • pp.1-15
    • /
    • 2022
  • The weld quality has always been an important factor affecting the development of exposed CFT column-base joint. In this paper, a new type of exposed RCFST column-base joint is proposed, in which the high strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens, the varying axial force ratio (0, 0.25 and 0.5), were tested under cyclic loadings. In addition, the bending moment capacity, energy dissipation capacity and deformation capacity of column-base joints were clarified. The experimental results indicated that the axial force ratio increases the stiffness and the bending moment and improves the energy dissipation capacity of column-base joints. This is because a large axial force can limit the slip between steel tubular and infilled concrete effectively. The specimens show stable hysteresis behavior.

Investigation of the link beam length of a coupled steel plate shear wall

  • Gholhaki, M.;Ghadaksaz, M.B.
    • Steel and Composite Structures
    • /
    • 제20권1호
    • /
    • pp.107-125
    • /
    • 2016
  • Steel shear wall system has been used in recent years in tall buildings due to its appropriate behavior advantages such as stiffness, high strength, economic feasibility and high energy absorption capability. Coupled steel plate shear walls consist of two steel shear walls that are connected to each other by steel link beam at each floor level. In this article the frames of 3, 10, and 15 of (C-SPSW) floor with rigid connection were considered in three different lengths of 1.25, 2.5 and 3.75 meters and link beams with plastic section modulus of 100% to the panel beam at each floor level and analyzed using three pairs of accelerograms based on nonlinear dynamic analysis through ABAQUS software and then the performance of walls and link beams at base shear, drift, the period of structure, degree of coupling (DC) and dissipated energy evaluated. The results show that the (C-SPSW) system base shear increases with a decrease in the link beam length, and the drift, main period and dissipated energy of structure decreases. Also the link beam length has different effects on parameters of coupling degrees.

소규모 철골조 노출형 주각부의 반복가력 실험 (Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures)

  • 임우영;유영찬;유미나
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.34-45
    • /
    • 2017
  • 본 연구에서는 소규모 철골조에 대한 기존 건축물의 접합부 현황조사와 분석을 통해 노출형 주각부에 대한 내진성능을 평가하였다. 총 9개의 주각부에 대한 반복가력 실험을 통해 휨강도, 변형능력, 그리고 초기강성 등이 조사되었다. 실험의 주요 변수는 베이스 플레이트의 두께, 앵커볼트의 개수와 매립깊이, 앵커볼트 후크의 유무, 그리고 리브 플레이트의 유무이다. 본 실험결과에 의하면, 주각부의 휨거동은 앵커볼트의 개수와 매립깊이, 그리고 베이스 플레이트의 두께에 영향을 받는 것으로 나타났다. 반면에, 주각부에 설치된 리브플레이트는 휨강도에 큰 영향을 주지 않는 것으로 나타났다. 종합적으로 노출형 철골 주각부와 기초부 그리고 앵커볼트 등이 모두 현행 구조기준을 만족한다고 할지라도, 앵커볼트와 기초부 콘크리트 사이의 부착력이 충분하지 않을 경우, 슬립형 거동이 관측되어 개선이 필요한 것으로 파악되었다. 앵커볼트의 매립깊이가 현행 구조기준을 만족하고, 앵커볼트에 후크가 설치된 경우, 노출형 주각부의 초기강성은 주각부가 구속되었을 때의 휨강성 하한값의 약 15% 수준인 것으로 나타났다.

Investigation of performance of steel plate shear walls with partial plate-column connection (SPSW-PC)

  • Azandariani, Mojtaba Gorji;Gholhaki, Majid;Kafi, Mohammad Ali;Zirakian, Tadeh;Khan, Afrasyab;Abdolmaleki, Hamid;Shojaeifar, Hamid
    • Steel and Composite Structures
    • /
    • 제39권1호
    • /
    • pp.109-123
    • /
    • 2021
  • This research endeavor intends to use the implicit finite element method to investigate the structural response of steel shear walls with partial plate-column connection. To this end, comprehensive verification studies are initially performed by comparing the numerical predictions with several reported experimental results in order to demonstrate the reliability and accuracy of the implicit analysis method. Comparison is made between the hysteresis curves, failure modes, and base shear capacities predicted numerically using ABAQUS software and obtained/observed experimentally. Following the validation of the finite element analysis approach, the effects of partial plate-column connection on the strength and stiffness performances of steel shear wall systems with different web-plate slenderness and aspect ratios under monotonic loading are investigated through a parametric study. While removal of the connection between the web-plate and columns can be beneficial by decreasing the overall system demand on the vertical boundary members, based on the results and findings of this study such detachment can lower the stiffness and strength capacities of steel shear walls by about 25%, on average.

A new base plate system using deformed reinforcing bars for concrete filled tubular column

  • Park, Yong-Myung;Hwang, Won-Sup;Yoon, Tae-Yang;Hwang, Min-Oh
    • Steel and Composite Structures
    • /
    • 제5권5호
    • /
    • pp.375-394
    • /
    • 2005
  • An experimental study was conducted to develop a new base plate anchorage system for concrete filled tubular column under an axial load and a moment. The column was connected to a concrete foundation using ordinary deformed reinforcing bars that are installed at the inside and outside of the column. In order to investigate the moment resisting capacity of the system, horizontal cyclic loads are applied until the ultimate condition is reached with the axial load held constant. To derive a design method for moment resisting capacity, the reinforced concrete section approach was investigated with the assumption of strain compatibility. The results by this approach agreeded well with those of experiments when the bearing pressure of confined concrete and tangent modulus of steel bars are assumed appropriately. Also, it was found that the column interaction curve can be used to predict the yield strength of the base plate system.

연강 판재의 맞대기 용접에서 아크에 작용하는 자기력의 해석 (Analysis of Electro-Magnetic Force Acting on Arc Column in Butt-Joint Welding of Mild Steel Plate)

  • 배강열
    • Journal of Welding and Joining
    • /
    • 제23권4호
    • /
    • pp.73-80
    • /
    • 2005
  • Arc blow being occurred by Electro-Magnetic force(EMF) during the electric arc welding prevents the formation of a sound weldment. In this study, the effects of arc position, groove size, tack weld and base plate on the EMF in a butt-joint welding of mild steel plate are analyzed by a computer simulation based on the finite element method. The EMF can be numerically identified to be caused by a difference of the magnetic flux-density between ahead of and behind the arc in case that the workpiece locates asymmetrically around the uc. When there exists an air gap of groove ahead of the arc in the welding direction, the similar magnetic force has been producted regardless of the arc position and the gap size. The tack weld alleviates the magnetic force to about one fourth at the finish end of the workpiece. The magnetic force can be also significantly reduced with the base plate to about one fifth at the start end of the workpiece containing a tack weld.

소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상 (Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.1-12
    • /
    • 2019
  • 소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 "Rocking" 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.

CFT 교각 기초부의 거동특성 (Behavior of the Foundation of Concrete Filled Steel Tubular Pier)

  • 이하림;김희주;황원섭
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.491-498
    • /
    • 2011
  • 본 연구는 CFT 교각 기초부의 구조상세 개선을 목적으로 상용 유한요소해석 프로그램인 ABAQUS를 이용하여 축하중 및 횡하중을 받는 강재기둥 베이스플레이트 접합부의 전반적인 구조적 거동과 설계변수의 영향을 검토하고자 한다. 이를 위해 현행 교각 기초부의 설계기준을 분석하였고, 선행연구의 실험을 토대로 수치해석을 실시하여 해석기법의 타당성을 검증하였다. 검증된 해석기법을 이용하여 교각 기초부의 파괴형상 및 응력분포를 분석하였으며, 다양한 설계변수(베이스플레이트, 이형철근, 기둥의 강종 및 치수)가 전체 구조물에 미치는 영향을 비교분석하였다.