Journal of Advanced Marine Engineering and Technology
/
제29권5호
/
pp.571-578
/
2005
Stresses of main stop valve and control valve casings for the steam turbines of power plants are analyzed by the finite element method. The stress intensity is obtained to check the results on the basis of the design criteria of ASME boiler and pressure vessel code. To verify accuracy of the finite element analysis. analyzed stresses are compared with those measured during the hydrostatic pressure test. Stress category drawings. which play an important role in evaluating casting defects, are produced from the analysis results, and important points in casting of the valve casings are discussed in terms of the stress category.
The High Strength Concrete REsearch Team of the Dong-Ah Construction R&D Institute has achieved the preactical use of the PHC pile manufacture technique at the Dong-Ah Chang-dong PC Plant. Components of the high strength concrete are used high strength cement, admixtures(water reducing high range admixture, micro silion fume, fly ash, gypsum). The design strength required 800kg/$\textrm{cm}^2$ was developed raging from 870kg/$\textrm{cm}^2$ to 1010kg/$\textrm{cm}^2$. The new manufacture procedure of HPC pile which include placing, molding, steam curing is able to apply a current PC pile manufacture procedure easily without using the high pressure steam curing.
The aim of the study was to evaluate the water treatment of pressurized water reactor secondary side by the mixed amine of ammonia and ethanolamine, from the standpoint of corrosion control, as compared with all volatile treatment of ammonia. The pressurized water reactor systems have switched a secondary side pH control agent to minimize the corrosion in the moisture separator/reheater and feedwater heater systems and the transport of corrosion products into steam generator. As results of field test, pH was increased in the steam generator and the wet steam area of moisture separator/reheater and the concentration of Fe were decreased by more than 50% as compared with water treatment of ammonia.
The Characteristics of dividing the dispersed bubble, plug, and slug steam-water flow in the horizontal junctions with horizontal branches have been experimentally investigated. The experimental investigation of the separation phenomena in a $45^{\circ}$ horizontal wye with equal pipe inner diameter of 25 mm is presented to provide a data base for the development and verification of the analytical models. The phase separation and pressure distribution in the three legs of each test section are obtained through the set of measurements made in the present work. And the dependence of phase separation on different parameters, such as inlet quality and mass flux, is discussed.
Corn starch was extruded under relatively low shear, high moisture, and low temperature. Puffing of corn starch dough was induced by injecting $CO_2$gas in the range from 0MPa to 0.09MPa. Piece density and compressive modulus for puffed corn starch were decreased by increasing the injection pressure to 0.07MPa, and increased above 0.07MPa. the microstructure of corn starch puffed with $CO_2$gas showed thick cell size, compared with those puffed with steam. RVA paste viscosity curves of corn starch puffed with $CO_2$had different patterns from those puffed with steam, probably resulted from partial gelatinization of starch. Water absorption and solubility were not significantly changed by $CO_2$injection pressure, but the average degree of polymerization was reduced by higher $CO_2$injection. The water absorption, water solubility, and the average degree of polymerization for corn starch puffed with $CO_2$were significantly lower than those puffed with steam.
In this study, the axial ODSCC occurrence of domestic OPR 1000 steam generator tube was caused by the tube weakness and the sludge accumulation in the secondary side of steam generator. Inconel 600 HTMA used as tube material is related to most of tube leakage accidents in the world and also these ODSCCs were detected mainly at the 5th TSP(Tube Support Plate) to the 8th TSP of hot leg side. These elevations(5th TSP to 8th TSP) pave the way for the sludge accumulation. As a result of EC(Eddy Current) Bobbin and RPC data analysis, ODSCCs were occurred at contact points of tube and tube support plate. The more accumulated sludge, the higher occurrence frequency of ODSCC.
Compact steam boiler is a useful heat exchanger in a space-intensive system. There are some constraints in terms of sizing and designing the space confined in the system which is usually used in vessels. In this study, design considerations for heavy duty heat exchangers of compact steam boilers are presented and evaluated. Especially, evaporator tubes of marine boiler which are exposed to a high temperature environment are considered. Also, extended surface designs with a high temperature are examined. In order to determine the criteria with considerations of both heat transfer rate and pressure drop in the heat exchanger, they are evaluated with major variables, such as the tube diameter, the number of tubes, and the tube length. Finally, the design parameters are estimated as the bare tubes are installed instead of the finned tubes.
Steam tables including superheated, saturated and compressed region were simultaneously modeled using the neural networks. Pressure and temperature were used as two inputs for superheated and compressed region. On the other hand Pressure and dryness fraction were two inputs for saturated region. The outputs were specific volume, specific enthalpy and specific entropy. The neural network model were compared with the linear interpolation model in terms of the percentage relative errors. The criterion of judgement was selected with the percentage relative error of 1%. In conclusion the neural networks showed better results than the interpolation method for all data of superheated and compressed region and specific volume of saturated region, but similar for specific enthalpy and entropy of saturated region.
Securing the integrity of steam generator tubes is an essential requirement for safe operation of nuclear power plants. Therefore, tubes that do not satisfy integrity requirements are no longer usable and must be repaired according to the related requirements. In general, the repair criterion is that the damage depth is more than 40% of the tube wall thickness. However, the plugging limit can be changed and be applied, provided a technical proof is given that integrity can be secured against specific degradation at a specific plants and that approval can be obtained from a regulatory agency. A typical example is alternative repair criteria for defects within the tube sheet or tube support plates. In this paper, a background of establishing the plugging limit for steam generator tubes and changes in maintenance criteria are reviewed as examples.
Based on the Deep Q-Network(DQN) algorithm of reinforcement learning, an active fault-tolerance method with incremental action is proposed for the control system with sensor faults of the once-through steam generator(OTSG). In this paper, we first establish the OTSG model as the interaction environment for the agent of reinforcement learning. The reinforcement learning agent chooses an action according to the system state obtained by the pressure sensor, the incremental action can gradually approach the optimal strategy for the current fault, and then the agent updates the network by different rewards obtained in the interaction process. In this way, we can transform the active fault tolerant control process of the OTSG to the reinforcement learning agent's decision-making process. The comparison experiments compared with the traditional reinforcement learning algorithm(RL) with fixed strategies show that the active fault-tolerant controller designed in this paper can accurately and rapidly control under sensor faults so that the pressure of the OTSG can be stabilized near the set-point value, and the OTSG can run normally and stably.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.