• 제목/요약/키워드: Steam pressure

검색결과 900건 처리시간 0.026초

발전용 증기터빈 밸브 케이싱의 유한요소해석과 주조결함 평가 방법 (Finite Element Analysis and Evaluation of Casting Defects of Steam Turbine Valve Casings of Power Plants)

  • 이부윤;김원진;신현명
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.571-578
    • /
    • 2005
  • Stresses of main stop valve and control valve casings for the steam turbines of power plants are analyzed by the finite element method. The stress intensity is obtained to check the results on the basis of the design criteria of ASME boiler and pressure vessel code. To verify accuracy of the finite element analysis. analyzed stresses are compared with those measured during the hydrostatic pressure test. Stress category drawings. which play an important role in evaluating casting defects, are produced from the analysis results, and important points in casting of the valve casings are discussed in terms of the stress category.

상압증기양생방식에 의한 PHC PILE의 제조기술 연구 (An Experimental Study on Manufactural Technics of PHC Pile Using Low Pressure Steam Curing Method)

  • 김종흡;안상기;이동근;심흥섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.405-414
    • /
    • 1994
  • The High Strength Concrete REsearch Team of the Dong-Ah Construction R&D Institute has achieved the preactical use of the PHC pile manufacture technique at the Dong-Ah Chang-dong PC Plant. Components of the high strength concrete are used high strength cement, admixtures(water reducing high range admixture, micro silion fume, fly ash, gypsum). The design strength required 800kg/$\textrm{cm}^2$ was developed raging from 870kg/$\textrm{cm}^2$ to 1010kg/$\textrm{cm}^2$. The new manufacture procedure of HPC pile which include placing, molding, steam curing is able to apply a current PC pile manufacture procedure easily without using the high pressure steam curing.

  • PDF

복합아민 적용에 따른 원전 2차 계통 부식생성물 거동평가 (Evaluation of Corrosion Product Behavior in NPP Secondary System with Complex Amine)

  • 정현준;이인형;김영인
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.96-99
    • /
    • 2014
  • The aim of the study was to evaluate the water treatment of pressurized water reactor secondary side by the mixed amine of ammonia and ethanolamine, from the standpoint of corrosion control, as compared with all volatile treatment of ammonia. The pressurized water reactor systems have switched a secondary side pH control agent to minimize the corrosion in the moisture separator/reheater and feedwater heater systems and the transport of corrosion products into steam generator. As results of field test, pH was increased in the steam generator and the wet steam area of moisture separator/reheater and the concentration of Fe were decreased by more than 50% as compared with water treatment of ammonia.

수평Y자형 분지관에서 증기-물 이상류의 상분리에 관한 실험적 연구 (Experimental Studies on Phase Separation of Steam-Water Two Phase Flow in Horizontal Y-Branching Conduit)

  • 안수환
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.886-893
    • /
    • 2000
  • The Characteristics of dividing the dispersed bubble, plug, and slug steam-water flow in the horizontal junctions with horizontal branches have been experimentally investigated. The experimental investigation of the separation phenomena in a $45^{\circ}$ horizontal wye with equal pipe inner diameter of 25 mm is presented to provide a data base for the development and verification of the analytical models. The phase separation and pressure distribution in the three legs of each test section are obtained through the set of measurements made in the present work. And the dependence of phase separation on different parameters, such as inlet quality and mass flux, is discussed.

탄산가스 주입이 압출팽화 옥수수전분의 성질에 미치는 영향 (Effect of $CO_2$Gas injection on Properties of Extruded Corn Starch)

  • 류기형;강선희;이은용;임승택
    • 한국식품영양과학회지
    • /
    • 제26권3호
    • /
    • pp.436-442
    • /
    • 1997
  • Corn starch was extruded under relatively low shear, high moisture, and low temperature. Puffing of corn starch dough was induced by injecting $CO_2$gas in the range from 0MPa to 0.09MPa. Piece density and compressive modulus for puffed corn starch were decreased by increasing the injection pressure to 0.07MPa, and increased above 0.07MPa. the microstructure of corn starch puffed with $CO_2$gas showed thick cell size, compared with those puffed with steam. RVA paste viscosity curves of corn starch puffed with $CO_2$had different patterns from those puffed with steam, probably resulted from partial gelatinization of starch. Water absorption and solubility were not significantly changed by $CO_2$injection pressure, but the average degree of polymerization was reduced by higher $CO_2$injection. The water absorption, water solubility, and the average degree of polymerization for corn starch puffed with $CO_2$were significantly lower than those puffed with steam.

  • PDF

OPR 1000 증기발생기 전열관의 ODSCC 고찰 (A Study on ODSCC of OPR 1000 Steam Generator Tube)

  • 석동화;오창하;이재욱
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.16-19
    • /
    • 2010
  • In this study, the axial ODSCC occurrence of domestic OPR 1000 steam generator tube was caused by the tube weakness and the sludge accumulation in the secondary side of steam generator. Inconel 600 HTMA used as tube material is related to most of tube leakage accidents in the world and also these ODSCCs were detected mainly at the 5th TSP(Tube Support Plate) to the 8th TSP of hot leg side. These elevations(5th TSP to 8th TSP) pave the way for the sludge accumulation. As a result of EC(Eddy Current) Bobbin and RPC data analysis, ODSCCs were occurred at contact points of tube and tube support plate. The more accumulated sludge, the higher occurrence frequency of ODSCC.

  • PDF

밀집형 증기보일러의 고부하 열교환기 설계평가 (Design Evaluation of Heavy Duty Heat Exchangers for Compact Steam Boilers)

  • 김성일;양종인;최상민
    • 한국연소학회지
    • /
    • 제18권2호
    • /
    • pp.23-31
    • /
    • 2013
  • Compact steam boiler is a useful heat exchanger in a space-intensive system. There are some constraints in terms of sizing and designing the space confined in the system which is usually used in vessels. In this study, design considerations for heavy duty heat exchangers of compact steam boilers are presented and evaluated. Especially, evaporator tubes of marine boiler which are exposed to a high temperature environment are considered. Also, extended surface designs with a high temperature are examined. In order to determine the criteria with considerations of both heat transfer rate and pressure drop in the heat exchanger, they are evaluated with major variables, such as the tube diameter, the number of tubes, and the tube length. Finally, the design parameters are estimated as the bare tubes are installed instead of the finned tubes.

증기표의 과열, 포화 및 압축영역의 신경회로망 모델링 (Neural Network Modeling for the Superheated, Saturated and Compressed Region of Steam Table)

  • 이태환;박진현
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.872-878
    • /
    • 2018
  • Steam tables including superheated, saturated and compressed region were simultaneously modeled using the neural networks. Pressure and temperature were used as two inputs for superheated and compressed region. On the other hand Pressure and dryness fraction were two inputs for saturated region. The outputs were specific volume, specific enthalpy and specific entropy. The neural network model were compared with the linear interpolation model in terms of the percentage relative errors. The criterion of judgement was selected with the percentage relative error of 1%. In conclusion the neural networks showed better results than the interpolation method for all data of superheated and compressed region and specific volume of saturated region, but similar for specific enthalpy and entropy of saturated region.

원전 증기발생기 전열관 관막음 한계 고찰 (A Review of Plugging Limit for Steam Generator Tubes in Nuclear Power Plants)

  • 강용석;이국희
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.10-17
    • /
    • 2020
  • Securing the integrity of steam generator tubes is an essential requirement for safe operation of nuclear power plants. Therefore, tubes that do not satisfy integrity requirements are no longer usable and must be repaired according to the related requirements. In general, the repair criterion is that the damage depth is more than 40% of the tube wall thickness. However, the plugging limit can be changed and be applied, provided a technical proof is given that integrity can be secured against specific degradation at a specific plants and that approval can be obtained from a regulatory agency. A typical example is alternative repair criteria for defects within the tube sheet or tube support plates. In this paper, a background of establishing the plugging limit for steam generator tubes and changes in maintenance criteria are reviewed as examples.

Fault-tolerant control system for once-through steam generator based on reinforcement learning algorithm

  • Li, Cheng;Yu, Ren;Yu, Wenmin;Wang, Tianshu
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3283-3292
    • /
    • 2022
  • Based on the Deep Q-Network(DQN) algorithm of reinforcement learning, an active fault-tolerance method with incremental action is proposed for the control system with sensor faults of the once-through steam generator(OTSG). In this paper, we first establish the OTSG model as the interaction environment for the agent of reinforcement learning. The reinforcement learning agent chooses an action according to the system state obtained by the pressure sensor, the incremental action can gradually approach the optimal strategy for the current fault, and then the agent updates the network by different rewards obtained in the interaction process. In this way, we can transform the active fault tolerant control process of the OTSG to the reinforcement learning agent's decision-making process. The comparison experiments compared with the traditional reinforcement learning algorithm(RL) with fixed strategies show that the active fault-tolerant controller designed in this paper can accurately and rapidly control under sensor faults so that the pressure of the OTSG can be stabilized near the set-point value, and the OTSG can run normally and stably.