• Title/Summary/Keyword: Steady and Transient Analysis

Search Result 388, Processing Time 0.03 seconds

Conducted Noise Reduction in Three-Phase Boost Converter using Random (3상 승압형 컨버터에 의한 전도노이즈 감소)

  • Jung, Dong-Hyo;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.79-82
    • /
    • 2003
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

Characteristics of Thermo-Fluid Flow in Dilution Chamber of Micro-Dilution Tunnel for Diesel Particulate Measurement (디젤매연측정용 마이크로 희석터널의 희석챔버에서의 열유동 특성)

  • 김태권;김성훈;임문혁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.90-99
    • /
    • 2002
  • The main purpose of this study lies on the development of micro dilution tunnel based on the Sierra Dilution chamber model. As a primary examination, characteristics of flow and temperature distributions during the steady dilution process in dilution chamber are observed with numerical analysis. The penetration of dilution air through porous tube as well as wall temperature and temperature gradient inside porous tube are examined. The thermophoretic velocity in terms of temperature behavior inside porous tube are defined and examined. Based on the ratio of penetration and thermophoretic velocities, all part of porous tube are shown to be safe from the particulate depositions. However, The inlet portion of porous tube in addition to the portion of impinging of dilution air are marginally safe from the particulate depositions. Generally the safer design against particulate deposition is required in provision f3r steady dilution process and for transient process as well.

Magnetic Shielding Characteristics of the Slitted Electrothermal Shield (틈새를 낸 열전자 차폐막의 자기차폐특성)

  • 이홍배;배동진;김석환;원영진;한성진;차귀수;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.562-566
    • /
    • 1991
  • Many research and development activities have found that Superconducting Generators (SCG) have advantages such as high efficiency, light weight, small size, large unit size and good steady-state stability over conventional ones. However the transient stability of SCG is comparable to that of conventional ones. One way to improve the transient stability of SCG is to apply quick-response excitation system to the SCG. For this purpose, an SCG with an electrothermal shield of short electric time constants should be developed. In this paper, a new electrothermal shield, called slitted electrothermal shield(SES), is proposed. The SES can easily transmit radiated heat into the ends of the shield as in the conventional electrothermal shields(CES) and can easily pass magnetic flux produced by armature and field windings. By finite element analysis and experimental test, the slitting effects of SES on magnetic shielding are compared. Good agreement is obtained between simulated and test results.

  • PDF

Measuring Thermal Conductivity of Nanofluids and Heat Transfer Enhancement (나노유체의 열전도율 측정과 열전달 향상)

  • Lee, Shin-Pyo;Choi, Cheol;Oh, Je-Myung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.147-150
    • /
    • 2006
  • A new class of heat transfer fluid with higher thermal conductivity, called nanofluids has been developed by Dr. S. Choi about decade ago. Many exciting experimental and theoretical results have been reported worldwide to predict the thermal conductivity enhancement of nanofluids, however, they sometimes show excessive large discrepancies between each other. This kind of disagreements in thermal conductivity data is partly ascribable to the accuracy of the measuring apparatus, that is, mostly used THM(transient hot-wire method). New thermal conductivity measuring method whose principle is different from that of conventional THM is proposed in this article and measurements and uncertainty analysis were made for the three nanofluid samples with different particle concentration of pure, 2% and 4% of AlN nanofluids.

  • PDF

Comparative Study on Water Hammer for Pump Station in High Pressurized Pipes in Kuwait

  • Shim, Kyu Dae;Kang, Yong Suk;Choung, Joon Yeon;Abdellatif, Mohamed;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.265-269
    • /
    • 2017
  • Because of abrupt changes for velocity in water, transient flow is occurred in practical life. To reduce and avoid the high or low pressure of pipe network system, various surge protection facilities are used to prevent the risk in pipe network system. Especially, we focused on study not only preventing positive and negative pressure but also selecting adequate equipment for high pressurized pipelines. Several critical cases were considered by undertaking a steady state hydraulic study and transient dynamic simulation and we suggested that the surge vessel of various surge protection system was recommended to control high and low pressures on pipeline system in perspective.

  • PDF

Design and Analysis of Large Capacity Lithium Polymer Battery Charger for Hybrid Electrical Vehicle (HEV용 중대형 2차전지 충전기 설계 및 해석)

  • Oh Dong-Seob;Oh Sung-up;Seong Se-jin;Choi Jae-dong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.87-91
    • /
    • 2004
  • In this paper, the paralleled forward converter, that is generally used as the power supply for the low voltage, high current load, is described. The proposed forward converter for battery charging could be provided the power without failure not only in steady state but also in the transient period by the step load variation or the unexpected faults among the converter modules. Each converter nodule designed is operated alone with the self closed controller for the elevation of stability, performance, reliability, and maintainability. The frequency response of the designed converter module is analyzed, and the stability is confirmed in analytic method. And the experiments of the paralleled battery charger are carried out in steady state, in the step load variation.

  • PDF

The Analysis and Simulation of Current Source Inverter-Induction Motor System Using Switching Function Representation (스위칭함수에 의한 전류형 인버어터 유도전동기 시스템의 해석 및 시뮬레이션)

  • 박민호;전태원;정승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.5
    • /
    • pp.185-192
    • /
    • 1986
  • This paper deals with the general mathmatical model of the CSI-fed induction motor system. The inverter is represented by a switching function matrix which is combined with the dg model of an induction motor. Complete system model is given by a set of differential equations in a closed form, which inherently includes the harmonic effects of the converter and the inverter. The model is valid in evaluating both the transient and steady state responses, while the more simple analytical model can be derived from the general model, in a steady state. With the model proposed, the digital simulation is carried out on a 10KVA CSI-induction motor system and the simulation results show good agreements with experimental ones.

  • PDF

Characteristic Analysis of Buck Converter by using the Non-Linear Instantaneous Following PWM Controller (강압형 컨버터의 비선형 순시추종 PWM 제어기의 특성 분석)

  • Ra, Byung-Hun;Kim, Sang-Don;Kwon, Soon-Kurl;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.378-381
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of DC-DC converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

터보펌프 공급식 액체 로켓엔진의 시동 과도 해석

  • Park, Soon-Young;Nam, Chang-Ho;Moon, In-Sang;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.142-152
    • /
    • 2005
  • There are two definite objects for developing the startup transient of liquid rocket engine. One is to achieve the repeatability of startup to ensure higher reliability, and the other is to reduce the time of the startup transient. Typically in the initial phase of engine development as we are currently opposing, it is hard to estimate engine startup time due to the lack of experiences. In this work, a startup transient analysis tool was developed with the introduction of the mathematical model for each component of pump-fed liquid rocket engine system. Startup transient was investigated for a 25 ton class gas generator cycle engine to find necessary time for reaching steady state from startup and this enabled to reveal dynamic characteristics of the engine.

  • PDF

Numerical Analysis of Water Hammer in Condenser Cooling Water Systems (콘덴서 냉각수 계통내의 수격현상 에 관한 수치해석)

  • 장효환;정회범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.638-646
    • /
    • 1985
  • Water hammering in nuclear or thermal power plant condenser cooling water systems in mathematically modeled and numerically analyzed based on the method of characteristics. Effects of variations of the discharge valve operating condition and the system geometry on the hydraulic transients are investigated for the cases when all or one of four pumps are tripped accidently due to loss of offisite power. Effects of ocean waves and tides on the steady-state and the transient operations are also studied. Water column separation in taken into account whenever necessary by means of a simplified physical model.