• 제목/요약/키워드: Steady State cycle

검색결과 185건 처리시간 0.026초

Flow Restored SSFP Sequence in NMR Imaging

  • 정관진;안우연;나종범;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 춘계학술대회
    • /
    • pp.25-27
    • /
    • 1990
  • By designing the gradient pulses to be velocity compensated during one pulse cycle in SSFP (steady state free precession) imaging, the flowing spins can be maintained in the steady state. In the new SSFP sequence the flow signal which might be lost in conventional SSFP imaging sequences can be restored owing to the signal contribution from the preceding pulse cycles. By using the proposed SSFP sequence substantial restoration of the flow signal has been observed for the CSF (cerebro spinal fluid) of the human head.

  • PDF

과냉 회로를 갖는 이산화탄소 냉동시스템에 대한 성능 해석 (Performance Analysis for CO2 System with Sub-cooling loop)

  • 김진만;고성규;김무근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.723-728
    • /
    • 2007
  • In order to evaluate the performance of carbon dioxide cycle with a sub-cooling loop. a simulation system was developed to predict the steady state of $CO_2$ trans-critical cycle. Mathematical models are derived to describe the relationships between the system's coefficient of performance and other operating parameters The mathematical models are based entirely on the basic mass and energy conservation law and thermodynamic and transport properties of carbon dioxide A parametric study has been conducted in order to investigate the effect of sub-cooling loop and various operating conditions on the cycle performance. An optimal mass fraction of a refrigerant flowing through sub-cooling cycle existed for the given evaporating temperature, high pressure and air inlet temperature through gas cooler.

이산화탄소 사이클에서 팽창장치의 영향에 관한 수치적 연구 (Numerical Study for the Effect of Expansion Device on the Performance of the $CO_2$ Cycle)

  • 김무근;김욱중;김유진
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.84-90
    • /
    • 2004
  • In order to evaluate the performance of carbon dioxide cycle, a simulation model was developed to predict the steady state performance of $CO_2$ transcritical cycle. The expansion process is treated as an isenthalpic throttling process or isentropic expansion process. The mathematical model is based entirely on the basic energy conservation law and thermodynamic and transport properties of $CO_2$. A Parametric study has been conducted in order to investigate the effect of isentropic efficiency of expansion turbine and various operating conditions on the cycle performance. An optimal heat rejection pressure existed for the given evaporating temperature and outlet temperature of gas cooler.

A Load Compensator Based on One-Cycle Control with Plug-In Repetitive Control

  • Hu, Jian;Sun, Zhaohui;Ma, Hao;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.443-454
    • /
    • 2015
  • This study proposes a novel one-cycle control scheme with a plug-in repetitive controller for load compensator. The novelty of this scheme lies in the combination of high dynamics and the simplicity of a one-cycle controller and good steady-state harmonic suppression ability of the repetitive controller. In addition, the proposed scheme can reduce the effect of the harmonics in phase voltage for the existence of the repetitive controller. Finally, experimental results on a three-phase, four-wire, three-level load compensator are reported to validate the effectiveness of the proposed control scheme.

두 탑 PSA공정의 상세 동적모사 및 초기운전조건 결정 (Rigorous dynamic simulation and determination of initial operating conditions for two-bed PSA processes)

  • 황덕재;문일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1520-1523
    • /
    • 1997
  • A rigorous dynamic simulation was performed in binary gas mixture H$_{2}$/CO (70:30 vol.%) to determinate start-up operating conditions of PSA(Pressure Swing Adsorption) processes. The rigorous dynamic model for the PSA process contains an Ergun equation for expressing the pressure drop in a bed, and valve equations to compute the boundary pressure change of the bed. As the result of the continuous dynamic simulation of 100 operating cyles in various initial conditions, the unsteady-state appeared in the early period and the cyclic steady-state came out about 20th cycle in feed condition and vaccum condition, and 30th cycle in pure H$_{2}$ condition. As time goes by valve equations made change the pressure at each end of the bed in ressurization, countercurrunt-depressurization and pressure equalization steps. The H$_{2}$ purity and the recovery is 99.99% and 86.73% respectively, which is slightly higher than the experimental data. Main contributiion of this study includes supplying fundamental technologies of handling combined variables PSA processes by developing rigorous models.

  • PDF

자동차 환경검사에 의한 대기오염물질 배출계수 및 연비 산출 (Emission Factor and Fuel Economy Calculation Using Vehicle Inspection and Maintenance Program)

  • 이태우;길지훈;박준홍;엄명도;김종춘;이대엽
    • 한국자동차공학회논문집
    • /
    • 제17권5호
    • /
    • pp.97-106
    • /
    • 2009
  • An objective of this study is to give practical information that could be used for calculating pollutant emission factors and fuel economy from Korean Inspection & Maintenance program, which has been using steady state acceleration simulation mode. Concentration results from I/M test is adequately converted to mass emission factors and fuel efficiency data, which have unit of g/km and km/L, respectively. Exhaust volume flow(EVF), which is for converting emission result from concentration to mass, is measured by tracer method in various vehicle speed - power condition. It is found that there is an apparent second order relationship between EVF and vehicle inertia weight. EVF is expressed in function of vehicle inertia weight in order to estimate EVF in I/M site without measuring device. Converted mass emission results from measured EVF and raw emission analyzer show a satisfactory agreement with those from conventional CVS-bag type measurement system. Mass emission factors and fuel efficiency from measured EVF and estimated EVF also show good agreement to each other. Considering that an I/M program has great advantages to recruit-based emission test in terms of the number of test vehicle, the information in this study can be used for developing an alternative procedure to collect more various data to establish national database of mobile emission factors and fuel economy, even though the driving cycle in I/M program is steady state cycle rather than transient cycle.

다단연소사이클 엔진 파워팩 시동 해석 시뮬레이터 개발 (Simulator Development for Startup Analysis of Staged Combustion Cycle Engine Powerpack)

  • 이수지;문인상
    • 한국추진공학회지
    • /
    • 제19권5호
    • /
    • pp.62-70
    • /
    • 2015
  • 액체로켓엔진은 시동단계에서 갑작스런 압력 및 온도 등의 부하변동이 발생할 수 있다. 따라서 성공적인 액체로켓엔진 개발과 함께 비용, 시간을 절감하기 위해 시동 해석이 필요하다. 본 연구에서는 다단연소사이클 액체로켓엔진 파워팩에 대한 시동 해석 시뮬레이터를 개발하여 압력 및 유량 밸런스를 통한 유량을 결정하고 터빈 및 펌프의 수학적 모델링을 통해 최종적으로 시간에 따른 터보펌프의 회전속도를 구하였다. 시동 해석 결과, 정상상태도달까지 약 1.3초가 소요되었으며 이때의 회전속도로는 27,500 rpm을 얻었다. 또한 안정적 시동을 위한 적절한 시퀀스 제시가 가능함을 확인했다.

동특성을 고려한 열펌프의 엑서지 해석 (Exergy analysis of heat pump in consideration of its dynamic response)

  • 장기태;남관우;정상권
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

Numerical study on Wells turbine with penetrating blade tip treatments for wave energy conversion

  • Cui, Ying;Hyun, Beom-Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권5호
    • /
    • pp.456-465
    • /
    • 2016
  • In order to optimize the performance of a Wells turbine with fixed guide vanes, the designs of an end plate and a ring on the tip of the turbine rotor are proposed as penetrating blade tip treatments. In this study, numerical investigations are made using computational fluid dynamics (CFD)-based ANSYS Fluent software, and validated by corresponding experimental data. The flow fields are analyzed and non-dimensional coefficients $C_A$, $C_T$ and ${\eta}$ are calculated under steady-state conditions. Numerical results show that the stalling phenomenon on a ring-type Wells turbine occurs at a flow coefficient of ${\phi}=0.36$, and its peak efficiency can reach 0.54, which is 16% higher than that of an unmodified turbine and 9% higher than in the case of an endplate-type turbine. In addition, quasi-steady analysis is used to calculate the mean efficiency and output work of a wave cycle under sinusoidal flow conditions. As a result, it has been found that the ring-type turbine is superior to other types of Wells turbines.

2 중효용 흡수식 히트점프의 난방 성능 해석 (Thermodynamic Analysis of an Absorption Heat Pump Heating System with LiBr-Water Solution)

  • 원승호;이원용;정헌생
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.73-80
    • /
    • 1989
  • This paper presents as assessment based on steady-state thermodynamic analysis and computer modeling of a double effect generation absorption heating cycle for solar air-conditioning to find operating temperature ranges. The influences of component temperatures on the heating coefficients of performance and mass flow ratio have been investigated to obtain optimum operating conditions for the proposed air conditioning system. And the single and double effect absorption cycles are compared with each other over the same range of temperatures.

  • PDF