• 제목/요약/키워드: Statistical Testing

검색결과 1,209건 처리시간 0.029초

지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교 (Comparison on marginal fitness and mechanical properties of copings with zirconia block and CAM type)

  • 정인성;전병욱;김원영;강재민
    • 대한치과기공학회지
    • /
    • 제39권2호
    • /
    • pp.75-82
    • /
    • 2017
  • Purpose: This study provided the basic data for selection the zirconia block and CAM by means of marginal fitness observations, flexural strength test and hardness test. Methods: Three dental zirconia blocks(ABCera, NaturaZ, ST98) and two dental milling machines(CAD/CAM MS, DWX-50) were used in this study. Metal abutment(diameter 10 mm, height 5 mm, inclined angle $3^{\circ}$ taper, 1 mm chamfer margin) was fabricated by Ti customized abutment, and then zirconia copings were fabricated for each ten specimens. Silicone replica technique was used to observe the marginal fitness of cross-sections with a stereomicroscope at ${\times}50$ magnification. The dental zirconia blocks was cut into 10 pieces each having a size of $25mm{\times}5mm{\times}1mm$, and fabricated according to the manufacturer's instructions, and flexural strength was measured using a universal testing machine. For hardness test, a micro Vickers hardness tester was used as it was in the flexural strength test. Statistical analysis was performed by one way ANOVA and post-test was performed by Scheffe test. Results: For marginal fitness of bucco-lingual axial, ZU group($59.7{\pm}10.3{\mu}m$) was the lowest, followed by RA, ZA, ZD, RD, RU. For marginal fitness of mesio-distal axial, ZU group($59.3{\pm}10.2{\mu}m$) was the lowest, followed by RA, ZA, RD, ZD, RU. One-way ANOVA showed statistically significant difference between groups(p<0.05). For flexural strength, ABCera block($718.0{\pm}57.2MPa$) was the highest, followed by NaturaZ, ST98. For hardness, ABCera block($1550.3{\pm}19.8Hv$) was the highest, followed by ST98, NaturaZ. There was no significant difference in flexural strength and hardness between blocks(p>0.05). Conclusion: Based on the results of this study, the type of dental zirconia block did influence the marginal fitness, and all dental zirconia blocks are expected to be suitable for clinical application. The highest flexural strength and hardness were ABCera block, and no statistically significant difference was observed.

코어 형태와 시멘트 종류에 따른 전부주조금관의 유지력에 관한 연구 (A STUDY OF CORE TYPE AND LUTING CEMENTS ON COMPLETE CAST CROWN RETENTION)

  • 백상현;장익태;이선형;양재호;허성주
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.169-177
    • /
    • 2000
  • The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.

  • PDF

The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics

  • Kim, Hyung-Tae;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권3호
    • /
    • pp.113-117
    • /
    • 2009
  • STATEMENT OF PROBLEM. Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE. The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS. Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad $S\ddot{a}ckingen$, Germany) were prepared in 40 mm (length) $\times$ 4 mm (width) $\times$ 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and $225^{\circ}C$ for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences ($\alpha$= .05). RESULTS. The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below $125^{\circ}C$ for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above $150^{\circ}C$, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION. The monoclinic phase started to appear after aging treatment above $100^{\circ}C$. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above $175^{\circ}C$. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.

간호대학생의 욕구구조에 관한 일 연구 (A STUDY IF PERSONALITY STRUCTURE AND HIERARCHY OF NEEDS IN COLLEGIATE NURSING STUDENTS)

  • 최계영
    • 대한간호학회지
    • /
    • 제4권1호
    • /
    • pp.38-49
    • /
    • 1974
  • Presently, the performance level of the college student has received a great deal of attention, particularly in the area of professional education. The problem of under achievement, especially in areas dealing with science and technology, has gone through considerable investigation by numerous Psychologists and Educators. Thus for, however, they have not been successful in determining conclusively the non-intellectual factors involved. The maladjustment problem of these students has been a thorn in the side of nursing education for some time. This topic has been discussed among nursing educators without any tangible results. Furthermore, the fact that the number of students who withdraw from nursing education programs before graduation has increased. This represents a major problem for nursing education. This problem area had increased attention drawn to it on October 1957, when Russia successfully launched to first satellite "Sputnik" into space. Various studies seem to indicate that factors related to over achievement and under.achievement can be found in the motivation of the students. This study is aimed at testing 3 hypotheses which hopefully will lead to a better understanding of the learning activities of nursing students and to determine some of their nonintellectually personality traits. Hypothesis I: learning activities in nursing students and persona1ity are correlated, there will be significant differences in personality need structures between 4 classes of nursing collegiate students. Sub-hypothesis: There will also be significant differences in the degree of student satisfaction in her major subject. Hypothesis I: If there is a special personality need structure which is required for the clinical learning activity in general, then there will be significant differences between the personality need structures of under-achievers and overachiever. Hypothesis II : If each clinical nursing subject requires different personality need structures, then there will be differences in personality need structure between the different clinical groups Methodology: 1. Tool: A Korean translation and correction of the Edwards Personal Preference Schedule of U.S.A. was used. 2. Subject and Test Method: Subjects were nursing students at Yonsei University, who enrolled for Fall semester of 1971. The Researcher herself executed the test for the test for the class as a group, and the absent students were tested indidually. Out of 307 students, 293 students (95.4%) were reported. 3. Statistical treatment: The mean and standard deviation for each of the 15 personality need variables were computed and the value of T-test was obtained to determine the differences in the personality need structures between each group. Results: 1, For the first hypothesis, the personality need structures between each of the 4 classes and the reported degree of satisfaction in major subject showed significant differences. Therefore the hypothesis I was accepted. 2. The comparison of personality need structure of under-achievers and over-achievers in clinical fields showed significant differences. Thus hypothesis II was accepted. 3. Personality need structure between clinical subject groups showed significant differences therefore the 3rd hypothesis was accepted.

  • PDF

크기효과를 고려한 복부보강이 없는 고강도 콘크리트 보의 전단강도 예측식의 제안 (Prediction of Shear Strength in High-Strength Concrete Beams without Web Reinforcement Considering Size Effect)

  • 배영훈;윤영수
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.820-828
    • /
    • 2003
  • 최근의 연구를 통해서, ACI 전단 규준은 크기가 크고 인장철근비가 낮은 보에서 비보수적 예측을 보이는 반면 깊은 보에 대해서는 보수적 예측을 보임을 알 수 있다. 이러한 ACI 전단 규준이 가지고 있는 문제점을 수정하기 위해, 본 연구에서는 스터럽이 없는 고강도 철근 콘크리트 보의 전단강도 계산시 크기효과와 아치작용을 고려한 극한 전단강도 예측식을 제안하였다. ACI 전단 규준의 수정을 위해 포함될 항은 과학적 이론 및 분석에 근거한 $f_{sr}$ (dr), $f_{si}$ (${\rho}$)와 $f_{aa}$ (a/d)항이며, 선형 및 비선형 회귀분석을 통해 도출되었다. 기존의 실험 데이터 약 300여 개를 이용하여 각각의 변수에 대한 제안식의 검증 및 제안식과 ACI 318-99 code, CEB-FIP model code, Kim &Park 식 및 Zsutty 식과의 비교를 수행하였다. 제안식은 간단한 형태를 지니고 있지만, 경제적이면서도 합리적인 안전율을 확보할 수 있는 전단강도를 예측한다. 따라서 제안식은 실무에서 콘크리트 구조물의 전단설계에 적용 가능할 것으로 판단된다.

하치조신경 마취 후 전기치수검사기(Electric pulp tester)를 이용한 하순부 감각 변화 평가 (Evaluation of the change of lower lip sensation after inferior alveolar nerve block by using the electric pulp tester)

  • 구명숙;김진욱;전영훈;권대근;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권6호
    • /
    • pp.464-469
    • /
    • 2011
  • Introduction: As dental implant surgery is becoming increasingly popular, it has become one of the causes for the hypesthesia of the inferior alveolar nerve, along with other surgical procedures, such as a third molar extraction. In addition, it tends to cause legal problems between the operator and patient. Therefore, there must be a proper method that is reliable, objective and economical to assess the nerve impairment. For this reason, an attempt was made to use an Electric Pulp Tester to assess inferior alveolar nerve block anesthesia. Materials and Methods: Thirty patients were tested. Electric pulp testing of the lower jaw skin was performed at the three different times, before anesthesia, at the onset of sensory changes and after 15 minutes waiting from the onset, and on the 10 points of the chin, which produced 10 sections on the skin area. Results: Twenty seven patients (90%) could feel the electric stimulus on the chin at all 10 points before local anesthesia and the scores represent the statistical differences between the right and left points except R4 and L4. After anesthesia, the difference between the right and left points (L3-R3, L4-R4, L5-R5) increased significantly with time but two points (L2, R2) showed no significant difference. The scores on the left chin (L3, L4, L5) increased, whereas the other points (R1-R5, L1, L2) showed no significant differences. Conclusion: This study highlights the potential clinical use of an electric pulp tester for an assessment of inferior alveolar nerve impairment.

관절염 환자의 운동행위 결정요인 (Determinant factors of Exercise behaviors in Patients with Arthritis)

  • 서길희;임난영
    • 근관절건강학회지
    • /
    • 제7권1호
    • /
    • pp.102-130
    • /
    • 2000
  • The aims of this study were to understand and to predict the determinant factors affecting the exercise behaviors and physical fitness by testing the Ponder's health promotion model, and to help the patients with rheumatoid arthritis and osteoarthritis perform the continuous exercise program, and to help them maximize the physical effect such as muscle strength. endurance, and fuctional status and mental effects including self efficacy and quality of life, and improve the physical and mental wellbeing, and to provide a basis for the nursing intervention strategies. We analyzed the clinical records of 208 patients with rheumatoid arthritis and degenerative arthritis who visited the outpatient clinics at H university hospital in Seoul between October 5, 1999 and October 24, 1999. Data were composed of self reported questionnaire and good of fitness score which were obtained by pedalling the ergometer of bicycle for 9 minutes. SPSS Win 8.0 and Window LISREL 8.12a were used for statistical analysis. 24 Of 54 hypothetical paths were supported in modified model, which was considered as a proper model with improved fit index. The physical fitness was directly influenced by exercise participation behavior and education level, and indirectly by physical fitness, while fatigue, physical disability, pastexercise behavior, life-style, self-efficacy, which explained 20% of physical fitness. The exercise participation were directly influenced by perceived benefits and self-efficacy, and indirectly influenced by life-style, fatigue and physical disability, and directly and indirectly by past exercise behavior, which explained 53% of exercise participation. Exercise score were directly affected by perceived health status, perceived benefits, self efficacy, and past exercise behavior, and were indirectly affected by fatigue, physical disability, and life-style, which explained 50%. Perceived health status were directly influeced by level of education, depression, sleep disorder, and physical disability, which explained 34% of perceived health status. Perceived benefit was directly influenced by fatigue, sleep disorder, physical disability, and life-style, which explained 45%. Perceived barriers was directly influenced by fatigue, sleep disorder, and lifestyle, which explained 9%. Self- efficacy was directly influenced by fatigue, physical disability, past exercise behavior, and level of education, which explained 61%. In conclusion, important variables for physical fitness were exercise participation and level of education, and variables affecting exercise participation were perceived self-efficacy, benefits, and past exercise behavior. Perceived self-efficacy of exercise was a significant predictor of exercise participation. Life-style, fatigue, and physical disability showed direct effects on perceived benefit, perceived barriers, and self-efficacy, and indirect effects on exercise behavior. Therefore, disease related factor should be minimized for physical performance and well being in nursing intervention for patients with rheumatoid arthritis, and plans to promote and continue exercise should be soaked to reduce disability. In addition, Exercise program should be planned and performed by the exact evaluation of exercise according to the ability of the patients and the contents to improve the importance of exercise and self efficacy in self control program, dedicated educational program should be involved.

  • PDF

딥 러닝 및 서포트 벡터 머신기반 센서 고장 검출 기법 (Sensor Fault Detection Scheme based on Deep Learning and Support Vector Machine)

  • 양재완;이영두;구인수
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.185-195
    • /
    • 2018
  • 최근 산업현장에서 기계의 자동화가 크게 가속화됨에 따라 자동화 기계의 관리 및 유지보수에 대한 중요성이 갈수록 커지고 있다. 자동화 기계에 부착된 센서의 고장이 발생할 경우 기계가 오동작함으로써 공정라인 운용에 막대한 피해가 발생할 수 있다. 이를 막기 위해 센서의 상태를 모니터링하고 고장의 진단 및 분류를 하는 것이 필요하다. 본 논문에서는 센서에서 발생하는 대표적인 고장 유형인 erratic fault, drift fault, hard-over fault, spike fault, stuck fault를 기계학습 알고리즘인 SVM과 CNN을 적용하여 검출하고 분류하였다. SVM의 학습 및 테스트를 위해 데이터 샘플들로부터 시간영역 통계 특징들을 추출하고 최적의 특징을 찾기 위해 유전 알고리즘(genetic algorithm)을 적용하였다. Multi-class를 분류하기 위해 multi-layer SVM을 구성하여 센서 고장을 분류하였다. CNN에 대해서는 데이터 샘플들을 사용하여 학습시키고 성능을 높이기 위해 앙상블 기법을 적용하였다. 시뮬레이션 결과를 통해 유전 알고리즘에 의해 선별된 특징들을 사용한 SVM의 분류 결과는 모든 특징이 사용된 SVM 분류기 보다는 성능이 향상되었으나 전반적으로 CNN의 성능이 SVM보다 우수한 것을 확인할 수 있었다.

확률통계기법을 이용한 해안지역 대수층의 염수침입 평가 (Evaluation of Saltwater Intrusion to Coastal Aquifer by Using Probability Statistics)

  • 정재열;함세영;김광구;이충모;전항탁;옥순일
    • 지질공학
    • /
    • 제26권3호
    • /
    • pp.371-382
    • /
    • 2016
  • 해안지역의 염수침입은 지하수내 다양한 지화학 성분들에 의해서 탐지될 수 있다. 그러나 불충분한 지하수 자료는 염수침입의 인지를 어렵게 한다. 확률밀도함수는 제한된 수질자료를 이용하여 더 넓은 범위의 확률적 예측이 가능하며 특성화된 확률밀도 분포 도출을 통하여 해안지역의 염수침입을 효과적으로 판단할 수 있다. 본 연구에서는 부산시의 해안지역 지하수, 해안유출수, 하천수의 화학성분에 대해서 확률통계기법을 적용함으로써 염수침입을 평가하였다. 이 연구에 의해서, 해수 중에 농도가 높은 항목인 Na+, Mg2+, K+, SO42−, Cl 은 염수의 영향유무 판별의 유용한 지시자인 것으로 판명된다. 한편, 지하수, 해안유출수 및 하천수에서 유사한 확률분포형태를 보이는 항목인 Si4+, Fe2+, NO3, PO43−은 염수영향에 대한 지시자로서 적당하지 않은 것으로 판단된다.

Comparing In Vitro and In Vivo Genomic Profiles Specific to Liver Toxicity Induced by Thioacetamide

  • Kang, Jin-Seok;Jeong, Youn-Kyoung;Shin, Ji-He;Suh, Soo-Kyung;Kim, Joo-Hwan;Lee, Eun-Mi;Kim, Seung-Hee;Park, Sue-Nie
    • Biomolecules & Therapeutics
    • /
    • 제15권4호
    • /
    • pp.252-260
    • /
    • 2007
  • As it is needed to assay possible feasibility of extrapolation between in vivo and in vitro systems and to develop a new in vitro method for toxicity testing, we investigated global gene expression from both animal and cell line treated with thioacetamide (TAA) and compared between in vivo and in vitro genomic profiles. For in vivo study, mice were orally treated with TAA and sacrificed at 6 and 24 h. For in vitro study, TAA was administered to a mouse hepatic cell line, BNL CL.2 and sampling was carried out at 6 and 24 h. Hepatotoxicity was assessed by analyzing hepatic enzymes and histopathological examination (in vivo) or lactate dehydrogenase (LDH) assay and morphological examination (in vitro). Global gene expression was assessed using microarray. In high dose TAA-treated group, there was centrilobular necrosis (in vivo) and cellular toxicity with an elevation of LDH (in vitro) at 24 h. Statistical analysis of global gene expression identified that there were similar numbers of altered genes found between in vivo and in vitro at each time points. Pathway analysis identified several common pathways existed between in vivo and in vitro system such as glutathione metabolism, bile acid biosynthesis, nitrogen metabolism, butanoate metabolism for hepatotoxicty caused by TAA. Our results suggest it may be feasible to develop toxicogenomics biomarkers by comparing in vivo and in vitro genomic profiles specific to TAA for application to prediction of liver toxicity.