• Title/Summary/Keyword: Station Keeping

Search Result 110, Processing Time 0.026 seconds

Feasibility Study for Development of New Stationkeeping System (Flapping Foil을 적용한 위치유지시스템 개발을 위한 운동시험)

  • Yu, Young-Jae;Sim, Woo-Lim;Kumar, Rupesh;Kim, Dong-Ju;Shin, Hyun-Kyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.189-195
    • /
    • 2019
  • In this study, experiments with a floater using flapping foils were performed to develop a new station keeping system that can maintain its position in waves without mooring lines. The foils applied to this system generate thrust using wave energy. In this experiment, the motion of the floater was analyzed in three different wave periods. Sixteen foils were attached to the cylindrical floater. The thrust of each foil was controlled by changing its azimuth angle, and three cases were compared. Based on the previous data, we made more precise measurements and found an optimal model for stationkeeping under each wave condition. We verified the potential of this new stationkeeping system using flapping foils, and conclusions were drawn from the results.

Collision Simulation of a Floating Offshore Wind Turbine Considering Ductile Fracture and Hydrodynamics Using Hydrodynamic Plug-in HydroQus

  • Dong Ho Yoon;Joonmo Choung
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.111-121
    • /
    • 2023
  • This paper intends to introduce the applicability of HydroQus to a problem of a tanker collision against a semi-submersible type floating offshore wind turbine (FOWT). HydroQus is a plug-in based on potential flow theory that generates interactive hydroforces in a commercial Finite element analysis (FEA) code Abaqus/Explicit. Frequency response analyses were conducted for a 10MW capacity FOWT to obtain hydrostatic and hydrodynamic constants. The tanker was modeled with rigid elements, while elastic-plastic elements were used for the FOWT. Mooring chains were modeled to implement station keeping ability of the FOWT. Two types of fracture models were considered: constant failure strain model and combined failure strain model HC-LN model composed of Hosford-Coulomb (HC) model & localized necking (LN) model. The damage extents were evaluated by hydroforces and failure strain models. The largest equivalent plastic strain observed in the cases where both restoring force and radiation force were considered. Stress triaxiality and damage indicator analysis showed that the application of HC-LN model was suitable. It could be stated that applications of suitable failure strain model and hydrodynamics into the collision simulations were of importance.

Hot Spot Detection of Thermal Infrared Image of Photovoltaic Power Station Based on Multi-Task Fusion

  • Xu Han;Xianhao Wang;Chong Chen;Gong Li;Changhao Piao
    • Journal of Information Processing Systems
    • /
    • v.19 no.6
    • /
    • pp.791-802
    • /
    • 2023
  • The manual inspection of photovoltaic (PV) panels to meet the requirements of inspection work for large-scale PV power plants is challenging. We present a hot spot detection and positioning method to detect hot spots in batches and locate their latitudes and longitudes. First, a network based on the YOLOv3 architecture was utilized to identify hot spots. The innovation is to modify the RU_1 unit in the YOLOv3 model for hot spot detection in the far field of view and add a neural network residual unit for fusion. In addition, because of the misidentification problem in the infrared images of the solar PV panels, the DeepLab v3+ model was adopted to segment the PV panels to filter out the misidentification caused by bright spots on the ground. Finally, the latitude and longitude of the hot spot are calculated according to the geometric positioning method utilizing known information such as the drone's yaw angle, shooting height, and lens field-of-view. The experimental results indicate that the hot spot recognition rate accuracy is above 98%. When keeping the drone 25 m off the ground, the hot spot positioning error is at the decimeter level.

Orbit Determination of GEO-KOMPSAT-2A Geostationary Satellite (천리안위성 2A호 지구정지궤도위성 궤도결정)

  • Yongrae Kim;Sang-Cherl Lee;Jeongrae Kim
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.2
    • /
    • pp.199-206
    • /
    • 2024
  • The GEO-KOMPSAT-2A (GK2A) satellite, which was launched in December 2018, carries weather observation payloads and uses the image navigation and registration system to calibrate the observation images. The calibration system requires accurate orbit prediction data and depends on the accuracy of the orbit determination accuracy. In order to find a possible way to improve the current orbit determination accuracy of the GK2A flight dynamic subsystem module, orbit determination software was developed to independently evaluate the orbit determination accuracy. A comprehensive satellite dynamic model is applied for a batch-type least squares filter. When determining the orbit, thrust firing during station-keeping maneuvers and wheel-off loading maneuvers is taken into account. One month of GK2A ranging data were processed to estimate the satellite position on a daily basis. The orbit determination error was evaluated by comparing estimates during overlapping estimation intervals.

Fully coupled multi-hull/mooring/riser/hawser time domain simulation of TLP-TAD system with MR damper

  • Muhammad Zaid Zainuddin;Moo-Hyun Kim;Chungkuk Jin;Shankar Bhat
    • Ocean Systems Engineering
    • /
    • v.13 no.4
    • /
    • pp.401-421
    • /
    • 2023
  • Reducing hawser line tensions and dynamic responses to a certain level is of paramount importance as the hawser lines provide important structural linkage between 2 body TLP-TAD system. The objective of this paper is to demonstrate how MR Damper can be utilized to achieve this. Hydrodynamic coefficients and wave forces for two bodies including second-order effects are obtained by 3D diffraction/radiation panel program by potential theory. Then, multi-hull-riser-mooring-hawser fully-coupled time-domain dynamic simulation program is applied to solve the complex two-body system's dynamics with the Magneto-Rheological (MR) Damper modeled on one end of hawser. Since the damping level of MR Damper can be changed by inputting different electric currents, various simulations are conducted for various electric currents. The results show the reductions in maximum hawser tensions with MR Damper even for passive control cases. The results also show that the hawser tensions and MR Damper strokes are affected not only by input electric currents but also by initial mooring design. Further optimization of hawser design with MR Damper can be done by active MR-Damper control with changing electric currents, which is the subject of the next study.

Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System (다겹보온자재의 보온성 비교 및 커튼개폐장치 개발)

  • Lee, Si-Young;Kim, Hark-Joo;Chun, Hee;Yum, Sung-Hyun;Lee, Hyun-Joo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • This study was accomplished to compare energy saving effects of several heat insulation materials in greenhouse and to develop new automatic opening and closing equipment which is suitable to the most effective heat insulation material. To find out more effective heat insulation material, the magnitude of heat transfer occurred through aluminum screen (ALS), non-woven fabric (NWF), double-layer aluminum screen with chemical cotton sheet (DAL), and multi-layer fabric screen material quilted with non-woven fabric, chemical cotton, poly foam, and polypropylene (MLF) were compared relatively. The results showed that the relative magnitude of heat transfer occurred through MLF was lower than DAL and ALS by 23.3% and 43.0% respectively. MLF screen material was the most effective compared with other heat insulation materials. But because of thickness, there was a need of new mechanism for automatic operation in greenhouse. Accordingly, new screen system using MLF-thick but profitable for keeping warm in greenhouse-was developed. Opening & closing equipment was designed to roll MLF with pipe axis during opening process and pull MLF with string during closing process with electric motors, clutches, drums, and so on. In hot pepper cultivation and energy saving test during winter time, the early stage yield of pepper under MLF screen system was higher than NWF by 27%, and gasoline consumption of MLF screen system was lower than NWF by 46%.

Production of Curd Yogurt from Platycodon grandiflorum(Jacq.) A.DC. (길경(桔梗)을 이용한 호상 요구르트 제조(製造))

  • Lee, Seong-Tae;Kim, Man-Bae;Kim, Dong-Kil;Ryu, Jae-San;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.6 no.4
    • /
    • pp.265-270
    • /
    • 1998
  • The curd yogurt was prepared from skim milk powder added with the juice, puree and powder, respectively, of the roots of Platycodon grandiflorum (Jacq.) A.DC. Twelve hours were proved to be best for fermentation of the curd yogurt, which showed 4.1 in pH and 1.15% in titratable acidity. Quality of the curd yogurt in sensory evaluation was best when 2 % of juice, 1 % of puree and 1 % of powder were added to the skim milk powder, respectively. When curd yogurt was kept at $5^{\circ}C$ for 9 days, pH decreased, while titratable acidity increased. The viscosity was highest with addition of puree 1%. After fermentation, number of viable cell was $6.2{\times}10^8/ml$ in control. $4.4{\times}10^8/ml$ in juice 2%, $3.7{\times}10^8/ml$ in puree 1% and $4.2{\times}10^8/ml$ in powder 1%. When curd yogurt was kept at $5^{\circ}C$ for 9 days, its keeping quality (pH, titratable acidity, viscosity and number of viable cells) were good.

  • PDF

MANAGING A PROLONGED STATION BLACKOUT CONDITION IN AHWR BY PASSIVE MEANS

  • Kumar, Mukesh;Nayak, A.K.;Jain, V;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.605-612
    • /
    • 2013
  • Removal of decay heat from an operating reactor during a prolonged station blackout condition is a big concern for reactor designers, especially after the recent Fukushima accident. In the case of a prolonged station blackout condition, heat removal is possible only by passive means since no pumps or active systems are available. Keeping this in mind, the AHWR has been designed with many passive safety features. One of them is a passive means of removing decay heat with the help of Isolation Condensers (ICs) which are submerged in a big water pool called the Gravity Driven Water Pool (GDWP). The ICs have many tubes in which the steam, generated by the reactor core due to the decay heat, flows and condenses by rejecting the heat into the water pool. After condensation, the condensate falls back into the steam drum of the reactor. The GDWP tank holds a large amount of water, about 8000 $m^3$, which is located at a higher elevation than the steam drum of the reactor in order to promote natural circulation. Due to the recent Fukushima type accidents, it has been a concern to understand and evaluate the capability of the ICs to remove decay heat for a prolonged period without escalating fuel sheath temperature. In view of this, an analysis has been performed for decay heat removal characteristics over several days of an AHWR by ICs. The computer code RELAP5/MOD3.2 was used for this purpose. Results indicate that the ICs can remove the decay heat for more than 10 days without causing any bulk boiling in the GDWP. After that, decay heat can be removed for more than 40 days by boiling off the pool inventory. The pressure inside the containment does not exceed the design pressure even after 10 days by condensation of steam generated from the GDWP on the walls of containment and on the Passive Containment Cooling System (PCCS) tubes. If venting is carried out after this period, the decay heat can be removed for more than 50 days without exceeding the design limits.

Characteristic Changes in Korean Native Cattle Spermatozoa Frozen-Thawed with L-Cysteine and/or Catalase

  • Lee, Sang-Hee;Lee, Kyung-Jin;Woo, Jea-Seok;Lee, Seung-Hwan;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Journal of Embryo Transfer
    • /
    • v.29 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • The objective of this study was to evaluate the characteristics of Korean Native Cattle sperm frozen-thawed with L-cysteine and/or catalase. The semen from bulls was collected by the artificial vagina method, and Triladyl containing 20% egg-yolk and/or L-cysteine (L), catalase (C) and L-cysteine + catalase was added to the diluted semen for cryopreservation. The results showed that sperm viability was significantly higher in the L-cysteine + catalase ($69.49{\pm}3.16%$) group than in the control ($60.5{\pm}3.94%$) group (p<0.05). Acrosome damage was significantly lower in the L-cysteine ($17.12{\pm}1.08%$) group than in the control ($21.46{\pm}1.14%$), catalase ($20.54{\pm}0.76%$), and L-cysteine + catalase ($19.29{\pm}0.65%$) groups (p<0.05). In addition, the level of intact mitochondria in the spermatozoa was significantly higher in the L-cysteine ($58.65{\pm}1.39%$) group than in the control ($50.63{\pm}2.37%$) group (p<0.05). The hydrogen peroxide level in the frozen-thawed sperm was significantly lower in the L-cysteine ($3.74{\pm}1.66%$), catalase ($4.65{\pm}1.87%$), and L-cysteine + catalase ($8.11{\pm}2.15%$) groups than in the control ($13.22{\pm}1.6%$) group (p<0.05). The glutathione level was significantly higher in the L-cysteine ($1.33{\pm}0.03%$) group than in the control ($1.08{\pm}0.06%$), catalase ($1.05{\pm}0.02%$) and L-cysteine + catalase ($1.11{\pm}0.03%$) groups (p<0.05). In conclusion, L-cysteine and catalase could protect the membrane of Korean Native Cattle sperm from damage during sperm cryopreservation. Especially, L-cysteine was more effective for keeping acrosomes and mitochondria intactness during sperm cryopreservation.

A Study on a Robust Clustered Group Multicast in Ad-hoc Networks (에드-혹 네트워크에서 신뢰성 있는 클러스터 기반 그룹 멀티캐스트 방식에 관한 연구)

  • Park, Yang-Jae;Lee, Jeong-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.10C no.2
    • /
    • pp.163-170
    • /
    • 2003
  • In this paper we propose a robust clustered croup Multicast in Ad-hoc network. The proposed scheme applies to weighted clustered Algorithm. Ad-hoc network is a collection of wireless mobile hosts forming a temporary network without the aid of any centralized administration or reliable support services such as wired network and base station. In ad hoc network routing protocol because of limited bandwidth and high mobility robust, simple and energy consume minimal. WCGM method uses a base structure founded on combination weighted value and applies combination weight value to cluster header keeping data transmission by scoped flooding, which is the advantage of the exiting FGMP method. Because this method has safe and reliable data transmission, it shows the effect to decrease both overhead to preserve transmission structure and overhead for data transmission.