• Title/Summary/Keyword: Static tensile test

Search Result 228, Processing Time 0.032 seconds

Restitution Behaviors and Mechanical Characteristics of Strings (스트링의 반발거동과 역학적 특성)

  • 김태용;박진무
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.543-546
    • /
    • 2000
  • Static and dynamic experiments were done to study on the restitution behaviors of strings. The elastic and viscoelastic model were compared. To apply a linear viscoelastic model (Kelvin model) to longitudinal behaviors of strings, static and dynamic tensile tests were done. Using their results, it should be intended to acquire damped stress (Stress related to velocity), and to calculate the viscoelastic coefficient. Fixing both ends, string was pushed by the loadcell attached to the tensile tester. The experimental results were in accordance with the calculated results using the Kelvin model acquired from the results of longitudinal tensile test. But the results of falling mass experiments, the behaviors of strings were near to elastic model. The clamping condition of strings in both sides has an effected on the value of COR. The smaller contact area, the grower the value of COR.

  • PDF

The Static Overload Effect Estimations on Fatigue Strength by The Measurement of Local Strain Variation at The Weldment Toe (용접 토우부의 국부적 변형률 측정을 통한 용접부의 정적 과하중에 따른 피로강도의 변화 평가)

  • Lee, Hyun-Woo;Kim, Ju-Hwan;Kim, Hyun-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.59-66
    • /
    • 2001
  • Fatigue strength of the welding structure is governed by the residual stress at the weldment toe and static tensile overloads were known as relieving the residual stresses. In this study, static tensile overloads were applied to the welding structures which caused the relief of residual stresses. The amount of residual stress relief was found as proportional to the change of fatigue limit at the given conditions. Based on the fact of the proportionality between the change of fatigue limit and that of residual stress, simple measurement technique is proposed. Modified stress-life curves base on proposed technique gave good agreement with test results.

  • PDF

A Novel Tensile Specimen and Test Machine for Mechanical Properties of MEMS Materials (MEMS 소재의 기계적 특성 평가를 위한 인장형 시편 및 시험기 제작)

  • Park, Jun-Hyub;Kim, Chung-Youb;Lee, Chang-Seun;Choa, Sung-Hoon;Song, Ji-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.258-263
    • /
    • 2004
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of materials used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed an uniaxial testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, new techniques and procedures for measuring strength are described.

  • PDF

Dynamic Constitutive Equations of Auto-Body Steel Sheets with the Variation of Temperature (I) - Dynamic Material Characteristics with the Variation of Temperature - (차체용 강판의 온도에 따른 동적 구성방정식에 관한 연구 (I) - 온도에 따른 동적 물성 특성 -)

  • Lee, Hee-Jong;Song, Jung-Han;Park, Sung-Ho;Huh, Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.174-181
    • /
    • 2007
  • This paper is concerned with the thermo-mechanical behavior of steel sheet for an auto-body including temperature dependent strain rate sensitivity. In order to identify the temperature-dependent strain rate sensitivity of SPRC35R, SPRC45E and TRIP60, uniaxial tensile tests are performed with the variation of the strain rates from 0.001/sec to 200/sec and the variation of environmental temperatures from $-40^{\circ}C$ to $200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained from the static tensile test and that at the intermediate strain rate is obtained from the high speed tensile test. Experimental results show that the variation of the flow stress and fracture elongation becomes sensitive to the temperature as the strain rate increases. It is observed that the dynamic strain aging occurs with TRIP60 at the temperature above $150^{\circ}C$. Results also indicate that the flow stress and tincture elongation of SPRC35R are more dependent on the changes of strain rates and temperature than those of SPRC45E and TRIP60.

The Estimation of Fatigue Strength of Structure with Practical Dynamic Force by Inverse Problem and Lethargy Coefficient (구조물의 피로강도평가를 위한 역문제 및 무기력계수에 의한 실동하중해석)

  • 양성모;송준혁;강희용;노홍길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.106-113
    • /
    • 2004
  • Most of mechanical structures are composed of many substructures connected to one another by various types of mechanical joints. In automotive engineering, it is important to study these connected structures under various dynamic forces for the evaluations of fatigue life and stress concentration exactly. In this study, the dynamic response of vehicle structure to external forces is classified an inverse problem involving strains from the experiment and the analysis. The practical dynamic forces are determined by the combination of the analytical and experimental method with analyzed strain by quasi-static finite element analysis under unit force and with measured strain by a strain gage under driving load, respectively. In a stressed body, inter-molecular chemical bonds are failed beyond the certain magnitude. The failure of molecular structure in material is considered as a time process of which rate is determined by mechanical stress. That is, the failure of inter-molecular chemical bonds is the fatigue lift of material. This kinetic concept is expressed as lethargy coefficient. And S-N curve is obtained with the lethargy coefficient from quasi-static tensile test. Equivalent practical dynamic force is obtained from the identification of practical dynamic force for one loading point. Using the practical dynamic force and S-N curve, fatigue life of a window pillar is analyzed with FEM under the identified force by the procedure of above mentioned.

Static Behavior of Reinforced Railway Roadbed by Geotextile Bag (지오텍스타일 백으로 보강된 철도노반의 정적거동 분석)

  • Lee, Dong-Hyun;Shin, Eun-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.180-186
    • /
    • 2006
  • In this study, a large-scale laboratory model test, 2-D and 3-D numerical analyses were conducted to verify the reinforcement effect by utilizing geotextile bag on the railway roadbed. Static loading which simulated train load was applied on the geotextile bag-reinforced railway roadbed and also unreinforced railway roadbed, Computer program named Pentagon which is a part of FEM programs was used in the numerical analysis. Based on the results of laboratory test, 2-D and 3-D numerical analyses, the effect of load distribution and settlement reduction was found to be depending on the geotextile characteristics, tensile strength of geotextite, and interface friction angle between geotextile bags. In general, the result of 2-D and 3-D numerical analyses shows lower value than that of laboratory test. Also, the result of 3-D numerical analyses shows lower value than that of 2-D numerical analyses because of its stress transfer effect.

Static test on failure process of tubular T-joints with initial fatigue crack

  • Wang, Yamin;Shao, Yongbo;Song, Shengzhi;Yang, Dongping
    • Steel and Composite Structures
    • /
    • v.24 no.5
    • /
    • pp.615-633
    • /
    • 2017
  • Fatigue crack initiated in welded tubular joints due to cyclic loading may produce harmful effect on the integrity of the tubular structures. To study such effect, both fatigue and static tests on nine circular tubular T-joint specimens made of carbon steel materials were carried out. The specimens were subjected to tensile loading in both fatigue and static tests. The load-displacement relation, the crack propagation and the failure mode of the specimens are all analyzed. The deterioration of the static strength of the cracked T-joints is also investigated and evaluated through an area reduction factor. Experimental results indicate that the static strength of a tubular T-joint with a surface crack seems to decrease slightly while a through crack has relatively remarkable effect on the reduction of the static strength. Additionally, experimental results also show that the toughness of the materials and the geometry of the specimens play an important role on the failure process of cracked tubular T-joints.

A Study on the Acoustic Emission Characteristics of Weld Heat Affected Zone in SWS 490A Steel(1) (SWS 490A 강의 용접 열영향부 음향방출 특성 에 대한 연구(1))

  • 이장규;우창기;박성완;윤종희;조진호;김봉각;구영덕
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 2004
  • The object of this study is to investigate the effect of compounded welding through the AE(Acoustic Emission) characteristics for weld HAZ(Heat Affected Zone) under the static tensile test. This study was carried out an SWS 490A, high tension steel for electric shield metal arc welding(SMAW), $CO_2$ gas arc welding and TIG welding. Data displays are based on the measured parameters of the AE signals, along with environmental variables such as time and load. The accumulated AE event curve of HAZ definitely have the point of inflection subject to tensile test. The results of the tensile test of HAZ come out electric shield arc welding >$CO_2$ gas arc welding>TIG welding in case of single welding, but generally the tensile test of HAZ come out electric shield arc welding> TIG welding > $CO_2$ gas arc welding. These history plots give us useful and powerful information to analyze the results of material evaluation testing.

Experimental Evaluation Study on the Integrity of Plastic Shell Structure using Acoustic Emission Technique (음향방출기법을 응용한 플라스틱 쉘 구조물의 건전성 평가 연구)

  • Shul, Chang-Won;Lee, Kee-Bhum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.12
    • /
    • pp.39-47
    • /
    • 2005
  • An acoustic emission technique is applied to the tensile tests of the plastic specimen under the different test speeds and the structural integrity evaluation of the plastic shell structure. Several AE characteristics are acquired from the tensile tests and they are proven to be useful parameters in evaluating its structural integrity. The results shows that tensile strength has almost constant value over some higher speed region while revealing some increasing tendency in strength as the test speeds up in lower speed region. The crack initiation loads and locations are accurately evaluated during the static compression testing of the plastic shell structures by using acoustic emission technique.

High Temperature Tensile Stress Behavior of Hydrogen Vessel Composite Materials for Hydrogen Fuel Cell Bus (수소버스용 내압용기 복합재의 열적환경에 따른 기계적 물성 연구)

  • Hyunseok, Yang;Woo-Chul, Jung;Kwang Bok, Shin;Man-Sik, Kong
    • Composites Research
    • /
    • v.35 no.6
    • /
    • pp.425-430
    • /
    • 2022
  • In this study, the mechanical properties of the pressure vessel composite exposed to the thermal environment were evaluated to establish the standard for high temperature static pressure test of the pressure vessel for hydrogen bus. As the tensile strength of the composite material approaches the glass transition temperature of the epoxy resin, the strength decreases due to the deterioration of the epoxy resin. In addition, it was confirmed that the tensile strength increased again due to the post-curing of the epoxy resin during long-term exposure. Therefore, the accelerated stress rupture test conditions of the pressure vessel for the hydrogen bus should be set based on the epoxy resin properties of the carbon fiber composite material.