• 제목/요약/키워드: Static plate load test

검색결과 82건 처리시간 0.036초

경골목조주택의 벽체-바닥체 못결합부의 감쇠비에 관한 연구 (Studies on Damping Ratio of Nailed Joint Connecting Wall to Floor in Light Frame House)

  • 김광모;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권3호
    • /
    • pp.65-71
    • /
    • 1996
  • In the design of wood structures, the consideration of the dynamic load effect has been increased. Generally, damping ratio is presented as the method of considering dynamic load effect. So, the relationship between joint type and damping ratio was investigated. It has been known that the joint extremely damp the dynamic load in wood structures. Static test was performed to determine the effects of nail size and friction area on joint strength and stiffness. Joint strength and stiffness were increased with nail size. However, the static properties of joint was not affected by friction area. Cyclic test was performed to determine the effects of nail size, friction area and load magnitude on damping ratio, Damping ratio was affected by all factors. Increasing the width of the bottom plate was suggested as the most adequate method to increase the damping ratio without the reduction of the static properties of the structures.

  • PDF

지오그리드로 보강한 고속철도 노반의 거동 특성 (Behavior of High-Speed Rail Roadbed Reinforced by Geogrid under Cyclic Loading)

  • 신은철;김두환
    • 한국철도학회논문집
    • /
    • 제3권2호
    • /
    • pp.84-91
    • /
    • 2000
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. With the test results, the bearing capacity ratio, elastic rebound ratio, subgrade modulus and the strain of geogrids under loading were investigated. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to estimate the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

강철도교에 대한 외부 후긴장 보강공법의 적용에 관한 실험 및 해석적 연구 (An Experimental and Analytical study on the Steel Plate Girder Railway bridge in the applying External Post-tensioning Method)

  • 박영훈;조선규;최정열;박용걸
    • 한국철도학회논문집
    • /
    • 제9권2호
    • /
    • pp.151-159
    • /
    • 2006
  • It analyzed the mechanical behaviors of non-ballasted railway bridge (steel plate girder type) with ballast reinforced on the finite element analysis, field test and laboratory test far the static and dynamic responses. The major objective of this study is to investigate the effects and application of reinforcement for steel plate girder railway bridge by the external post-tensioning method. The reinforcement of non-ballast railway bridge had obviously stable dynamic behaviors due to the additional dead force which was ballast. But in case of static behaviors, static displacements and stresses had increased nearly the allowable values. Therefore we analyzed the mechanical behaviors of non-ballasted railway bridge with ballast reinforced and external post-tensioning reinforced on the finite element analysis and laboratory test for the static and dynamic behavior. As a result, the reinforcement of ballasted railway bridge the external post-tensioning method are obviously effective for the additional dead force which is ballast. The analytical and experimental study are carried out to investigate the post-tension force decrease bending behavior and deflection in composite bridge for serviceability. The servicing railway bridge with ballast reinforced has need of the reasonable reinforcement measures which could be reducing the effect of additional dead load that degradation phenomenon of structure by an unusual. stresses and a drop durability.

고강도 콘크리트를 적용한 얇은 RC 판부재의 정적 강도 안전성 평가 (Structural Safety Evaluation for Static Strength of Thin Plate RC Member with High Strength Concrete)

  • 황훈희;박성용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.69-75
    • /
    • 2017
  • Structural safety evaluation for static strength of thin plate RC member with high strength concrete is conducted in this study. Static strengths were predicted and compared with the experimental values. Predicted values were calculated by the evaluation formula based on the punching shear behavior and the yield line theory which can appear in the plate members. Static load tests were carried out for the specimens with high strength concrete and the test results were compared with the required performance in design. The comparison results show that the specimens with high strength concrete have sufficient structural safety for flexural and punching shear performance required in design. High strength concrete specimens exhibited excellent strength despite their small thickness. The range of concrete strengths applied in this study was about 60 MPa to 100 MPa.

Static and Fatigue Behavior of RC Beams Strengthened with Steel Plates

  • Oh, Byung-Hwan;Cho, Jae-Yeol;Cha, Soo-Won
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.51-60
    • /
    • 2002
  • Strengthening of existing concrete structures is a major concern in recent years as the number of degraded structures increases. The purpose of this paper is to investigate the static and fatigue behavior of reinforced concrete (RC) beams strengthened with steel plates. To this end, a comprehensive test program has been set up and many series of strengthened beams have been tested. The major test variables include the plate thickness, adhesive thickness, and the shear-span to depth ratio. The test results indicate that the separation of plates is the dominant failure mechanism even for the full-span-length strengthened beams with steel plate. The theoretical ultimate load capacities for strengthened beams based on the full composite action of concrete beam and steel plate are found to be larger than the actual measured load capacities. The strengthened beams exhibit more dominant shear cracking as the shear-span to depth ratio decreases. The ultimate capacity of strengthened beams increases slightly with the increase of adhesive thickness, which may be caused by the late initiation of plate separation in the beams with thicker adhesive. A realistic concept of ductility for plate-strengthened beams is proposed in this study. It is seen that the strengthened beams show relatively low ductility compared with unstrengthened beams. The present study indicates that the strengthened beams exhibit much higher fatigue resistance than the unstrengthened beams. The increase of deflections of strengthened beams according to the number of load cycles is much smaller than that of unstrengthened beams. The present study provides very useful results for the realistic application of plate-strengthening method in reinforced concrete structures.

  • PDF

평면형 차륜 형상을 가진 탈선계수 측정용 윤축의 하중시험 (Load test of wheel-set for derailment coefficient measurement that have plane style wheel plate)

  • 함영삼;홍재성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.228-233
    • /
    • 2004
  • A derailment coefficient of railway vehicle is as one of important element that estimate running safety. Derailment coefficient is ratio of lateral load/vertical load happens in contact point between wheel and rail. Lateral load increases, dangerous of derailment can rise. There are ground and vehicle to measurement method of these derailment coefficient. Method of ground is simple, but when vehicles passes data of a point, there is shortcoming that acquire locally. Curved surface style wheel shape that use so far among vehicle method in this research wishes to be not but describe about static load test of wheel-set for derailment coefficient measurement that have plane plate shape that manufacture separate way and correction result etc. to test.

  • PDF

현장검증시험에 의한 선단변형 PHC말뚝들의 연직하중 지지특성에 관한 연구 (Axial Bearing Characteristics of Tip-transformed PHC Piles through Field Tests)

  • 최용규;김명학
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.107-119
    • /
    • 2018
  • PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝을 현장 시험 부지에서 시험시공하였다. 이들 선단변형 PHC말뚝들에 대하여 하중전이측정이 수반된 연직압축정재하시험을 실시하였으며 시공직후 항타후 동재하시험을 수행하였다. 또한 선단부만 그라우팅한 선단변형PHC말뚝에 대한 연직압축정재하시험도 실시하였다. 3가지 다양한 선단말뚝들 즉, PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 하중-침하량 거동은 거의 동일한 양상을 나타내었다. 따라서 말뚝이 선단지지층에 근입된 길이가 동일하고 말뚝 본체의 직경이 동일할 경우 확장판 선단부착 PHC말뚝 및 강관 선단부착 PHC말뚝의 지지력 증대 효과는 거의 없는 것으로 나타났다. 최종재하하중단계에서 PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 주면마찰력은 각각 전체 재하하중의 95.8%, 95.6%, 97.8%를 분담하였으며, 선단지지력은 전체 재하하중의 4.2%, 4.4%, 2.2%를 분담하였다.

가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험 (Model Test of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김성규;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

Experimental study on fatigue behavior of innovative hollow composite bridge slabs

  • Yang Chen;Zhaowei Jiang;Qing Xu;Chong Ren
    • Steel and Composite Structures
    • /
    • 제46권6호
    • /
    • pp.745-757
    • /
    • 2023
  • In order to study the fatigue performance of the flat steel plate-lightweight aggregate concrete hollow composite bridge slab subjected to fatigue load, both static test on two specimens and fatigue test on six specimens were conducted. The effects of the arrangement of the steel pipes, the amplitude of the fatigue load and the upper limit as well as lower limit of fatigue load on failure performance were investigated. Besides, for specimens in fatigue test, strains of the concrete, residual deflection, bending stiffness, residual bearing capacity and dynamic response were analyzed. Test results showed that the specimens failed in the fracture of the bottom flat steel plate regardless of the arrangement of the steel pipes. Moreover, the fatigue loading cycles of composite slab were mainly controlled by the amplitude of the fatigue load, but the influences of upper limit and lower limit of fatigue load on fatigue life was slight. The fatigue life of the composite bridge slabs can be determined by the fatigue strength of bottom flat steel plate, which can be calculated by the method of allowable stress amplitude in steel structure design code.

신형식 CFTA 거더 교량의 구조성능평가 (Structural Performance Analysis of New Type CFTA Girder Bridge)

  • 이지오;정민철;박경훈;공정식
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.15-22
    • /
    • 2011
  • 본 논문에서는 아치 형상을 갖는 강재 거더에 콘크리트가 충진되고 외부에 긴장력을 도입하여 구조적 효율성을 높인 CFTA 거더(Concrete-Filled and Tied Steel Tubular Arch Girder)의 아치효과와 구조적 성능을 검증하기 위해 정적하중재하실험을 수행하였고, 실험결과의 타당성을 검증하기 위해 유한요소해석을 수행하였다. CFTA 거더는 강재, 콘크리트, PS강재 등을 이용하여 각 재료의 역학적 장점을 최대한 발휘하도록 형상화하였다. 본 연구에서는 프레임해석프로그램으로 지간장 12m인 축소모형을 설계하였으며, 해석결과에 근거하여 정적재하실험이 수행되었다. 정적재하실험 결과, CFTA 거더의 구조적 성능과 안전성이 검증되었으며, 아치 효과에 의해 타 구조형식과는 다른 처짐 형상이 나타났다. 또한 ABAQUS 프로그램을 이용한 유한요소해석을 통해 차량 충돌 안정성과 정적재하실험결과의 타당성을 입증하였다.