• 제목/요약/키워드: Static load capacity

검색결과 530건 처리시간 0.024초

Evaluating the impacts of using piles and geosynthetics in reducing the settlement of fine-grained soils under static load

  • Shariati, Mahdi;Azar, Sadaf Mahmoudi;Arjomand, Mohammad-Ali;Tehrani, Hesam Salmani;Daei, Mojtaba;Safa, Maryam
    • Geomechanics and Engineering
    • /
    • 제20권2호
    • /
    • pp.87-101
    • /
    • 2020
  • The construction of combined pile-raft foundations is considered as the main option in designing foundations in high-rise buildings, especially in soils close to the ground surface which do not have sufficient bearing capacity to withstand building loads. This paper deals with the geotechnical report of the Northern Fereshteh area of Tabriz, Iran, and compares the characteristics of the single pile foundation with the two foundations of pile group and geogrid. Besides, we investigate the effects of five principal parameters including pile diameter and length, the number of geogrid layers, the depth of groundwater level, and pore water pressure on vertical consolidation settlement and pore water pressure changes over a year. This study assessed the mechanism of the failure of the soil under the foundation using numerical analysis as well. Numerical analysis was performed using the two-dimensional finite element PLAXIS software. The results of fifty-four models indicate that the diameter of the pile tip, either as a pile group or as a single pile, did not have a significant effect on the reduction of the consolidation settlement in the soil in the Northern Fereshteh Street region. The optimum length for the pile in the Northern Fereshteh area is 12 meters, which is economically feasible. In addition, the construction of four-layered ten-meter-long geogrids at intervals of 1 meter beneath the deep foundation had a significant preventive impact on the consolidation settlement in clayey soils.

무량복합 및 벽식 구조시스템의 내진성능평가 (Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures)

  • 강현구;이민희;김진구
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.259-266
    • /
    • 2012
  • 본 논문에서는 벽식 구조시스템의 일부 전단벽을 제거하여 공간의 가변성을 높인 무량복합 구조시스템의 내진성능을 ATC-63에 제시되어 있는 절차에 따라 파악하였으며, 동일한 규모의 벽식 구조시스템의 내진성능과 비교하였다. 해석모델로 12층 무량복합 및 벽식 구조시스템을 KBC 2009에 따라 설계하고 비선형 정적 및 비선형 증분 동적해석(IDA)을 수행하여 지진응답 및 붕괴거동을 파악하였다. 무량복합 시스템은 벽식 구조시스템 보다 적은 양의 콘크리트 물량으로 설계되었으며, 동일한 지진하중에 대하여 좀 더 큰 변위응답을 보이는 것으로 나타났다. IDA 해석결과 얻어진 붕괴 여유비(CMR)는 ATC-63에 제시된 한계상태를 만족하여 설계지진하중에 대하여 충분한 내진성능을 보유한 것으로 나타났다.

임플란트 고정체의 매식 경사에 따른 응력분석 (Stress analysis according to the different angulation of the implant fixture)

  • 이태엽;강동완
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.321-329
    • /
    • 2002
  • Bending moments results from offset overloading of dental implant, which may cause stress concentrations to exceed the physiological capacity of cortical bone and lead to various kinds of mechanical failures. The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different angulated placement of dental implant in mandibular posterior missing areas. The three kinds of finite element model, were designed according to 3 main configurations: Model 1(parallel typed placement of 2 fixtures), Model 2(15. distal angulated placement of one fixture on second molar area), Model 3(15. mesial angulated placement of one fixture on second molar area). The cemented crowns for mandibular first and second molars were made on the two fixtures (4mm 11.5). Three-dimensional finite element models by two fixtures were constructed with the components of the implant and surrounding bone. A 200N vertical static load were applied to the center of central fossa and the point 2mm apart from the center of central fossa on each model. The preprocessing, solving and postprocessing procedures were done by using FEM analysis software NISA/DISPLAY IV Version 10.0((Engineering Mechanics Research Corporation, USA). Von Mises stresses were evaluated and compared in the supporting bone, fixtures, and abutment. The results were as following : (1) Under the point loading at the central fossa, the direction of angulated fixture affected the stress pattern of implants. (2) Under the offset loading, the position of loading affected more on the stress concentration of implants compare to the angulated direction of implants. The results had a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the placement angulation of implant fixture is placed toward mesial or distal direction. In designing of the occlusal scheme for angulated placement, placing the occlusal contacts axially during chewing appears to have advantages in a biomechanical viewpoint.

쌍축 컨테이너선의 조종성능 특성 연구 (Study on the Maneuvering Characteristics of a Container Ship with Twin Skegs)

  • 김연규;김선영;김형태;유병석;이석원
    • 대한조선학회논문집
    • /
    • 제43권1호
    • /
    • pp.15-21
    • /
    • 2006
  • Recently, the attention to large container ships whose size is greater than 10,000 TEU container ship has been increased due to their increasing demand. The large container ship has twin skegs because of the engine capacity and large beam-draft ratio. In this paper, the maneuvering characteristics of a container ship with twin skegs were investigated through 4DOF(four degree of freedom) HPMM(Horizontal Planar Motion Mechanism) test and computer simulation. A mathematical model for maneuvering motion with 4DOF of twin skegs system was established to include effects of roll motion on the maneuvering motion. And to obtain roll-coupling hydrodynamic coefficients of a container ship, 4DOF HPMM system of MOERI which has a roll moment measurement system was used. HPMM tests were carried out for a 12,000 TEU class container ship with twin skegs at scantling load condition. Using the hydrodynamic coefficients obtained, simulations were made to predict the maneuvering motion. Rudder forces of twin-rudders were measured at the angles of drift and rudder. The neutral rudder angles with drift angles of ship was quite different with those of single skeg ship. So other treatment of flow straightening coefficient $\gamma_R$ was used and the simulation results was compared with general simulation result. The treatment of experimental result at static drift and rudder test was very important to predict the maneuverability of a container ship with twin skegs.

Efficient parameters to predict the nonlinear behavior of FRP retrofitted RC columns

  • Mahdavi, Navideh;Ahmadi, Hamid Reza;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제70권6호
    • /
    • pp.703-710
    • /
    • 2019
  • While fiber-reinforced plastic (FRP) materials have been largely used in the retrofitting of concrete buildings, its application has been limited because of some problems such as de-bonding of FRP layers from the concrete surface. This paper is the part of a wide experimental and analytical investigation about flexural retrofitting of reinforced concrete (RC) columns using FRP and mechanical fasteners (MF). A new generation of MF is proposed, which is applicable for retrofitting of RC columns. Furthermore, generally, to evaluate a retrofitted structure the nonlinear static and dynamic analyses are the most accurate methods to estimate the performance of a structure. In the nonlinear analysis of a structure, accurate modeling of structural elements is necessary for estimation the reasonable results. So for nonlinear analysis of a structure, modeling parameters for beams, columns, and beam-column joints are essential. According to the concentrated hinge method, which is one of the most popular nonlinear modeling methods, structural members shall be modeled using concentrated or distributed plastic hinge models using modeling parameters. The nonlinear models of members should be capable of representing the inelastic response of the component. On the other hand, in performance based design to make a decision about a structure or design a new one, numerical acceptance should be determined. Modeling parameters and numerical acceptance criteria are different for buildings of different types and for different performance levels. In this paper, a new method was proposed for FRP retrofitted columns to avoid FRP debonding. For this purpose, mechanical fasteners were used to achieve the composite behavior of FRP and concrete columns. The experimental results showed that the use of the new method proposed in this paper increased the flexural strength and lateral load capacity of the columns significantly, and a good composition of FRP and RC column was achieved. Moreover, the modeling parameters and acceptance criteria were presented, which were derived from the experimental study in order to use in nonlinear analysis and performance-based design approach.

A Quantitative Approach to Minimize Energy Consumption in Cloud Data Centres using VM Consolidation Algorithm

  • M. Hema;S. KanagaSubaRaja
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권2호
    • /
    • pp.312-334
    • /
    • 2023
  • In large-scale computing, cloud computing plays an important role by sharing globally-distributed resources. The evolution of cloud has taken place in the development of data centers and numerous servers across the globe. But the cloud information centers incur huge operational costs, consume high electricity and emit tons of dioxides. It is possible for the cloud suppliers to leverage their resources and decrease the consumption of energy through various methods such as dynamic consolidation of Virtual Machines (VMs), by keeping idle nodes in sleep mode and mistreatment of live migration. But the performance may get affected in case of harsh consolidation of VMs. So, it is a desired trait to have associate degree energy-performance exchange without compromising the quality of service while at the same time reducing the power consumption. This research article details a number of novel algorithms that dynamically consolidate the VMs in cloud information centers. The primary objective of the study is to leverage the computing resources to its best and reduce the energy consumption way behind the Service Level Agreement (SLA)drawbacks relevant to CPU load, RAM capacity and information measure. The proposed VM consolidation Algorithm (PVMCA) is contained of four algorithms: over loaded host detection algorithm, VM selection algorithm, VM placement algorithm, and under loading host detection algorithm. PVMCA is dynamic because it uses dynamic thresholds instead of static thresholds values, which makes it suggestion for real, unpredictable workloads common in cloud data centers. Also, the Algorithms are adaptive because it inevitably adjusts its behavior based on the studies of historical data of host resource utilization for any application with diverse workload patterns. Finally, the proposed algorithm is online because the algorithms are achieved run time and make an action in response to each request. The proposed algorithms' efficiency was validated through different simulations of extensive nature. The output analysis depicts the projected algorithms scaled back the energy consumption up to some considerable level besides ensuring proper SLA. On the basis of the project algorithms, the energy consumption got reduced by 22% while there was an improvement observed in SLA up to 80% compared to other benchmark algorithms.

지진하중을 받는 주철근 겹침이음된 철근콘크리트 교각의 곡률분석 (Experimental Curvature Analysis of Reinforced Concrete Piers with Lap-Spliced Longitudinal Steels subjected to Seismic Loading)

  • 정영수;박창규;송희원
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.41-49
    • /
    • 2006
  • 지난 1982년 우라카와 근해지진 및 1995년 효고현 남부 지진 등에 의하여 주철근이 겹침이음된 많은 교각들이 주철근 겹침이음부의 활동에 의한 휨-전단파괴를 발생하였음을 경험하였다. 철근콘크리트 교각의 내진성능은 소성힌지구간의 변형능력에 좌우되고 있으며, 이는 곡률연성도로서 평가된다. 우리나라에서는 1992년 내진 설계가 도입된 이후 철근콘크리트 교각의 주철근겹침이음에 대한 규정이 없었으나, 2005년 도로교 설계기준에서 주철근겹침음을 50% 이내에서 허용하고 있다. 본 연구는 단면 직경이 600 mm이고 형상비가 2.5 및 3.5인 주철근 겹침이음이 있는 철근콘크리트 교각에 대하여 지진시 소성힌지부의 곡률분포 및 곡률연성도에 대하여 조사하였다. 실험은 일정한 축력 $P=0.1f{ck}A_g$가 재하된 상태에서 변위제어 방식으로 준정적실험을 실시하였다. 실험결과 반복하중에 의한 주철근 겹침이음부에 활동이 발생하면, 주철근 겹침이음 구간 내의 곡률이 주철근 겹침이음이 없는 경우와 다르게 나타났다. 다시 말하면 주철근 겹침이음 실험체의 겹침이음 구간 중의 하부 곡률은 주철근 겹침이음이 없는 실험체의 경우보다 큰 값을 보이고 있으며, 상부는 작은 값을 보였다. 이로 인하여 교각실험체의 손상은 겹침이음 구간의 하부에 집중되어 휨파괴되는 모습으로 보이는 양상을 보였다.

하중 속도가 Smart UHPC의 자가 응력 감지 성능에 미치는 영향 (Effect of Loading Rate on Self-stress Sensing Capacity of the Smart UHPC)

  • 이선열;김민경;김동주
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.81-88
    • /
    • 2021
  • 최근 지진 빈도 증가로 구조물 건전도 모니터링 (SHM: Structural Health Monitoring, 이하 SHM) 시스템에 대한 관심이 증가하고 있다. Smart concrete는 전기-역학적 거동을 바탕으로 구조물 상태를 분석할 수 있는 기술이다. 하지만 콘크리트 구조물은 지진 시 정적 변형률 또는 하중 속도 보다 10배 이상 빠른 하중 속도가 작용하나 기존 연구 대부분은 정적 하중 속도에서의 감지 능력을 주로 조사하고 있다. 본 연구는 지진과 같이 높은 하중 속도에서 자가 응력감지 능력을 평가하기 위해 만능재료시험기 (UTM: Universal Testing Machine, 이하 UTM)를 사용하여 3가지 하중 재하 속도 (1, 4, 8 mm/min) 하에서 Smart Ultra High Performance Concrete (S-UHPC)의 전기-역학적 거동을 측정하였다. S-UHPC의 최대 압축 하중에서 Stress sensitive Coefficient (SC)는 1 mm/min 하중 속도 기준 -0.140%/MPa로 측정되었으나, 하중 속도가 각각 4, 8 mm/min으로 증가함에 따라 42.8 %, 72.7% 감소하였다. 전도성 재료의 변형 감소, 미세균열 증가로 인하여 S-UHPC의 감지능력이 하중속도 증가에 따라 감소하였지만, 그럼에도 불구하고 높은 하중 속도 하에서도 우수한 감지 성능을 보여 구조물 지진 하중 감지를 위한 SHM 시스템에 활용 가능함을 확인하였다.

비보강 조적조 건축물의 외부 보강에 따른 내진성능 연구 (A Study on Seismic Performance of External Reinforcement for Unreinforced Masonry Buildings)

  • 김종연;강종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권2호
    • /
    • pp.43-52
    • /
    • 2024
  • 내진설계 되지 아니한 조적조 건축물의 내진성능을 평가하고 건축물의 외부에 내진 보강 공법을 채택하여 내진성능을 향상시키고자 하였다. 내진성능을 평가하기 위해 건축물 내진설계 기준 및 해설(KDS 41 17 00 : 2019)과 기존 시설물(건축물) 내진성능 평가요령을 적용하였으며 비선형 정적해석으로 pushover해석을 수행하였다. 해석결과, 우리나라 주택의 내진설계 보급 비율이 낮고 주택의 많은 비중을 차지하고 있는 것이 조적조 건축물임을 고려하면 내진보강이 시급한 것으로 판단되었다. 조적조 건축물에 철골 보-기등+가새 프레임을 보강할 경우 층간 변형각은 X방향 0.043%이며 Y방향 0.047%로 나타나 규정을 만족하였다. 성능 수준별 중력하중 저항능력은 X, Y방향 모두 거주가능으로 판정되어 안전한 것으로 판단되었다. 건축물의 외부에 보강함으로써 주택의 거주성과 편의성을 확보하면서 공사가 가능할 것으로 보여지며 지진성능과 구조물의 거동을 보다 명확하게 예측할 수 있을 것으로 사료 되었다.

강종에 따른 고력볼트 보 이음부 인장거동 평가 (Evaluation of Tensile Behaviors of Beam Splice with High Strength Bolts According to Steel Grades)

  • 김희동
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.129-137
    • /
    • 2020
  • 건축구조용 강종을 사용한 고력볼트 보 이음부 설계시 연결판 강종을 어떻게 결정할 것인가에 대해 적절한 강종 선택 기준 제시가 필요한 상황이다. 본 연구는 이를 위한 기초 연구 단계로 보 부재 고력볼트 이음부 플랜지를 모사한 인장실험체에 대한 정적가력실험을 통해 건축구조용 강종 적용 유무에 따른 인장거동 차이를 평가하고, 그 결과를 후속 연구에 활용하는데 목적이 있다. 이를 위해 이음부 내력 및 거동에 영향을 미칠 것으로 예상되는 플랜지 및 연결판의 두께와 강종 및 강도를 주요 변수로 실험체를 설계 및 제작하였다. 총 48개 실험체에 대한 인장실험결과 모든 실험체에서 공칭강도를 적용한 설계인장강도를 충분히 상회하는 인장하중 저항능력을 나타냈으며 연결판 설계강도가 플랜지 판 설계강도의 1.25배를 상회할 경우 플랜지 판의 파단에 따른 종국 상태 도달 가능성이 지배적인 것으로 나타났다. 그리고 플랜지 강종의 변화에 따른 최대인장하중의 변화는 그리 크지 않은 것으로 나타났으나 변형에서는 차이가 나타났다. 그리고 실험 결과 보 부재의 강종과 연결판 두께가 이음부 거동에 영향을 미치는 주요 인자로 확인 되었다.