• 제목/요약/키워드: Static fatigue

검색결과 611건 처리시간 0.028초

Mechanical behavior and microstructural characterization of different zirconia polycrystals in different thicknesses

  • Arcila, Laura Viviana Calvache;Ramos, Nathalia de Carvalho;Campos, Tiago Moreira Bastos;Dapieve, Kiara Serafini;Valandro, Luiz Felipe;de Melo, Renata Marques;Bottino, Marco Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.385-395
    • /
    • 2021
  • PURPOSE. To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength. MATERIALS AND METHODS. Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.2 ± 0.1 mm in thicknesses). Energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed, and mechanical properties were assessed by Vickers hardness, IFR, quasi-static BFS and fatigue tests. RESULTS. All ceramics showed similar chemical compositions, but mainly differed in the amount of yttria, which was higher as the amount of cubic phase in the diffractogram (5Y-PSZ > 4Y-PSZ > 3Y-TZP). The 4Y- and 5Y-PSZ specimens showed surface defects under SEM, while 3Y-TZP exhibited greater grain uniformity on the surface. 5Y-PSZ and 3Y-TZP presented the highest hardness values, while 3Y-TZP was higher than 4Y- and 5Y-PSZ with regard to the IFR. The 5Y-PSZ specimen (0.7 and 1.2 mm) showed the worst mechanical performance (fatigue BFS and cycles until failure), while 3Y-TZP and 4Y-PSZ presented statistically similar values, higher than 5Y-PSZ for both thicknesses (0.7 and 1.2 mm). Moreover, 3Y-TZP showed the highest (1.2 mm group) and the lowest (0.7 mm group) degradation percentage, and 5Y-PSZ had higher strength degradation than 4Y-PSZ group. CONCLUSION. Despite the microstructural differences, 4Y-PSZ and 3Y-TZP had similar fatigue behavior regardless of thickness. 5Y-PSZ had the lowest mechanical performance.

모노레일 형식 경량전철차량 대차 하중시험에 관한 연구 (A Study on The Load Test of Bogie for Monorail-Type LRT)

  • 김원경;원시태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.939-950
    • /
    • 2011
  • In this study, the load test of rubber tire bogie for monorail type LRT. Bogie for rolling stock in safety operation of the vehicle as an essential core unit before applying to the vehicle safety and reliability should be tested sufficiently. Rubber tire monorail type bogie compared to the traditional bogie wheel lots of formats, the complexity of the load acting static load test, the bogie of the vehicle operation conditions by structural analysis by considering the loading conditions was evaluated by calculating. Test methods and evaluation criteria based on urban rail vehicle performance testing by applying the test were welded parts and materials for the results leading to material fatigue endurance test by applying the result of evaluating the structure has been identified as safe.

  • PDF

I 형강 격자 상판의 주부재 I형강에 대한 해석적 연구 (Analytical Study on I-beam of I-beam Grated Concrete slab)

  • 박창규;김용곤;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2001
  • Recently, there have been increased much concerns about repair and rehabilitation works for aged concrete structures. In particular, it is known that due to repeated overburden vehicle there are significantly increasing number of aged concrete bridge slabs, which are strongly needed to construct and rehabilitate by innovative construction method. The objective of this research is to develop the new construction method of concrete slab in bridge structure, which can contribute to minimize the traffic congestion during the repair and rehabilitation works of aged concrete slab, and can also sufficiently assure the quality through the minimization of in-situ works at the site. I-beams with punch holes, which are substituted instead of main reinforcing steels in concrete slabs, will be manufactured in accordance with the specification in the factory. and will be preassembled into the Panel. After erecting the preassembled panels in the site, concrete will be poured into the slab panel. This research is to investigate physical properties of I-Beam with punch holes itself through static and fatigue test with rational numerical analysis Finally this research is to suggest reformed I-beam through the numerical analysis.

  • PDF

화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

한국형 틸팅열차용 주행장치 프레임의 구조적 안전성 평가에 관한 시험적 연구 (Experimental Study on the Bogie Frame of Tilting Railway Vehicle for Assessment of Structural Safety)

  • 김정석;김남포;서승일
    • 한국정밀공학회지
    • /
    • 제23권1호
    • /
    • pp.166-173
    • /
    • 2006
  • This paper investigated strength of a bogie frame for Korean tilting train that is being developed in KRRI. In this study, static load tests based on Japanese Industrial Standard (JIS) were performed. In order to simulate vertical and lateral components generated by tilting link mechanism, four hydraulic actuators were used. The eight load cases such as vertical, lateral, traction, braking and driving gear loads were applied for evaluation of the strength of bogie frame. The stresses measured at the stress concentration points were assessed using Goodman diagram. From the experimental results, structural safety of the bogie frame could be ensured.

경부선을 주행하는 두 종류의 화차 대차프레임의 진동특성시험 및 진동증가 원인파악에 관한 연구 (Vibration characteristics test of two types bogie frame of a freight car on Kyeungbu line)

  • 홍재성;함영삼;백영남;오택열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1323-1326
    • /
    • 2004
  • A bogie frame of welded type have some problems. Some end beam has cracked. The cracks have profound influence on the safe freight service. The bogie consists of a frame, suspensions, brakes and wheel sets. Various analyses including a numerical simulation using a finite element method, a static load test, a fatigue test, and running test should be carried out to design the bogie. However cracks have been found at some end beams of the bogies mounted on the freight cars running with the high speed. The cracks of the end beam results in deterioration of the brake performance and the running safety. Numerical simulations and dynamic tests are carried out to figure out the causes of cracks in the existing bogie, and the vibrational characteristics of the improved bogie are compared with those of the conventional one. In this reports, the vibration characteristics were dealed with the most pressing matters for the solution of the end beam crack.

  • PDF

Shear Strength of Grout Type Transverse Joint

  • Kim, Yoon-Chil;Park, Jong-Jin
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2002
  • This is the first of two part series on experimental studies of grout type transverse joints. In this study, grout type transverse joints between precast concrete slabs are statically tested to determine the cracking loads and ultimate shear capacities of the grout type transverse joints. The tests are performed with a loading equipment designed and constructed especially in the lab to induce shear failures on the joints of the test specimens. Shape of the transverse joints, grouting materials and amount of prestress are selected as test parameters for the study. The results indicate that epoxy is an excellent grouting material which can be used in limited locations where large tensile stress is acting on the slab. Longitudinal prestressing is also an effective method to increase the shear strength of the transverse joints. A rational method to estimate the cracking and ultimate loads for the design of grout type transverse joints is proposed based on the static loading tests. Success of the tests with shear loading equipment allowed continuing the research further onto the fatigue strength of the grout type joints, which will be presented in the second part of the paper.

  • PDF

기계적인 하중에 의한 용접부 잔류응력에 이완에 관한 해석 (Numerical Analysis on Residual Stress relaxation by mechanical loading)

  • 서정원;구병춘;이동형;정흥채
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.872-877
    • /
    • 2004
  • Welding residual stresses are the main topics of welding research fields. The residual stresses and distortion of structures by welding exert negative effect on the safety of mechanical structures. That is, expansion of material by high temperature and distortion by cooling during welding process are caused by tensile and compressive residual stresses in welding material, and this residual stresses can induce fracture and fatigue problems of welding structures. The accurate prediction of residual stress and relaxation due to mechanical loading of weld zone is very important to improve the quality of weldment. In this study, a finite element modeling technique is developed to simulate the relaxation of residual stresses due to mechanical loading. The effects of load ratio for static and cyclic loading are evaluated based on analytical results.

  • PDF

철도교량용 T-MAT형 신축이음장치 완제품 성능시험에 관한 연구 (A Study on Verification Test of T-MAT Type Expansion Joint for Railway Bridge)

  • 유문식;우윤수;김현묵;최종문;윤태양;이안호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.552-556
    • /
    • 2003
  • Expansion joint is the absorbing structure when the upper structure of bridge have the drying shrinkage and creep from the change of temperature or construction badness. Because it has the fatigue from continuous vehicles traffic. the durability and performance is verified by the static and dynamic loading test In this study. we make the decision that T-MAT type expansion joint is applied in railway bridge and the expansion joint was tested by the criterion of Korea High Speed Rail Construction Authority.

  • PDF

용접구조물 피로해석 적용을 위한 기준응력 비교 연구 (A Benchmark study on the reference stress to supply fatigue analysis of welded structure)

  • 서정관;최홍민;이제명;백점기;김명현;김현수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.421-428
    • /
    • 2004
  • Various type of welded joints of the ship structure have been examined numerically and experimentally under bending and tensional cyclic constant-amplitude loading. Cyclic loading on structures can produce failures not readily predicted by conventional static analysis. The aim of a benchmark study is achieved with a generalization of the reference stress concept. Also different methods and procedures exist for the computation of the welded structure hot-spot stress a welded joints. These are either based on the extrapolation of stresses at certain reference points on the plate surface (or edge) close to the weld toe-as known from experimental investigations- or on the linearization of stresses in the through-thickness direction. In the present paper, the different methods are reviewed and applied to four different details in order to compare the methods with each other and to illustrate the differences.

  • PDF