• 제목/요약/키워드: Static and transient analysis

검색결과 131건 처리시간 0.024초

열차 진입 시 풍압에 의한 완전 밀폐형 승강장 스크린 도어(PSD)시스템의 구조 안정성 평가 (Evaluation of the Structural Stability of Platform Screen Door (PSD) due to Train Wind Pressure)

  • 이재열;류봉조;김동현;이은규;신광복
    • 한국철도학회논문집
    • /
    • 제9권5호
    • /
    • pp.594-600
    • /
    • 2006
  • In this study, transient and quasi-static analysis were done for the evaluation of structural integrity of the platform screen door due to train wind pressure. Fluent 6.0 was used to calculate the train wind pressure, and Ansys 10.0 was used to evaluate the structural stability of platform screen door due to train wind pressure. Transient analysis was used to check the design requirements of platform screen door, and quasi-static analysis was introduced to save the calculating time and check quickly structural performances when compared to those of transient analysis. The results show that structural stability of the platform screen door under train wind pressure is proven and quasi-static analysis can quickly check the structural integrity of platform screen door.

궤도차량의 차체구조해석 (A Structural Analysis of the Tracked Vehicle)

  • 이영신;최창;전병희;오재문
    • 전산구조공학
    • /
    • 제10권3호
    • /
    • pp.145-155
    • /
    • 1997
  • 본 연구에서는 ANSYS와 ABAQUS 상용 유한요소 코드를 이용하여 궤도차량의 정적.동적 해석을 충격하중과 주행하중에 대해서 수행하였다. 궤도차량이 충격하중을 받을 때 최대 동적 Von Mises응력은 상판의 빔보강재와 레이스링사이에서 발생하였으며 응력수준은 390-450MPa이다. 정하중에 대한 동하중수 1.6을 고려했을 경우 동적 해석과 동적하중계수가 포함된 정하중 해석은 유사한 결과를 보이고 있다. 과도응력은 주로 레이싱링 주위에서 발생하고 있다. 주행하중의 경우 최대응력은 로드휠 유기압 현가장치 #1번에서 450MPa정도이며, 정적해석과 비선형 해석의 결과가 유사하다.

  • PDF

승강장 스크린 도어(PSD)시스템의 구조 안정성 평가 (Evaluation of the Structural Stability of Platform Screen Door(PSD))

  • 이재열;류봉조;전재선;김동현;이은규;신광복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1190-1197
    • /
    • 2006
  • We have evaluated the structural stability of a platform screen door due to train wind pressure. The platform screen door was installed at the ground and underground station and had 65 meters in length. Also, the platform screen door was a safety device because it was placed between the train and the platform. The finite element analysis was used to calculate the stresses and deflections of platform screen door caused by wind pressure using ANSYS 10.0. Quasi-static analysis was introduced to save calculating time and check quickly structural performances when compared to those of transient analysis. The results show that structural stability of the platform screen door under train wind pressure is proven and quasi-static analysis can quickly check the structural integrity of platform screen door.

  • PDF

Numerical analysis of a long-span bridge response to tornado-like winds

  • Hao, Jianming;Wu, Teng
    • Wind and Structures
    • /
    • 제31권5호
    • /
    • pp.459-472
    • /
    • 2020
  • This study focused on the non-synoptic, tornado-like wind-induced effects on flexible horizontal structures that are extremely sensitive to winds. More specifically, the nonuniform, intensive vertical wind-velocity and transient natures of tornado events and their effects on the global behavior of a long-span bridge were investigated. In addition to the static part in the modeling of tornado-like wind-induced loads, the motion-induced effects were modeled using the semi-empirical model with a two-dimensional (2-D) indicial response function. Both nonlinear wind-induced static analysis and linear aeroelastic analysis in the time domain were conducted based on a 3-D finite-element model to investigate the bridge performance under the most unfavorable tornado pattern considering wind-structure interactions. The results from the present study highlighted the important effects due to abovementioned tornado natures (i.e., nonuniform, intensive vertical wind-velocity and transient features) on the long-span bridge, and hence may facilitate more appropriate wind design of flexible horizontal structures in the tornado-prone areas.

수도권 FACTS 상호영향 및 과도특성 분석 (Interaction and Transient Analysis to FACTS Devices in Seoul Area)

  • 윤종수;김재한;이성두;최장흠;서보혁
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1929-1935
    • /
    • 2010
  • This paper describes the operation effect of FACTS devices in the Korean power system. At the year of 2010, three FACTS devices is under commercial operation in the Seoul area. Among them, 345kV ${\pm}100MVA$ STATCOM at Mi-Geum substation and 345kV ${\pm}200MVA$ SVC at Dong-Seoul substation are very close at their electrical and geographical distance. Therefore, the additional analysis including interaction and mutual transient is necessary. Therefore, a detailed EMTDC/PSCAD simulation model was developed and steady-state/transient analysis was implemented.

345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석 (The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM)

  • 윤종수
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

Proposal for Increase of Thermal Margin in COLSS

  • Lee, Byung I.;Kim, Du I.;Kim, Jong J.;Kil S. Um;Lee, Chong C.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.508-513
    • /
    • 1997
  • One of the moot important constants to be Installed In COLSS, a monitoring system in CE typed reactors, is ROPM which would limit the operating space. This static ROPM was calculated from digital transient analysis assuming that every design basis transient was initiated from the most severe initial condition combination (LCO). Once It could be assured that core condition would not be located at none other than LCO, this static ROPM could be replaced with dynamic ROPM calculated at that condition and the dynamic ROPM would be definitely less than the static ROPM. In order to do, It must be required to calculate the transient discrete sensitivity parameters and parameters change distribution. The purpose of this report is just to propose the enlargement method for thermal margin.

  • PDF

Reactor core analysis through the SP3-ACMFD approach Part II: Transient solution

  • Mirzaee, Morteza Khosravi;Zolfaghari, A.;Minuchehr, A.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.230-237
    • /
    • 2020
  • In this part, an implicit time dependent solution is presented for the Boltzmann transport equation discretized by the analytic coarse mesh finite difference method (ACMFD) over the spatial domain as well as the simplified P3 (SP3) for the angular variable. In the first part of this work we proposed a SP3-ACMFD approach to solve the static eigenvalue equations which provide the initial conditions for temp dependent equations. Having solved the 3D multi-group SP3-ACMFD static equations, an implicit approach is resorted to ensure stability of time steps. An exponential behavior is assumed in transverse integrated equations to establish a relationship between flux moments and currents. Also, analytic integration is benefited for the time-dependent solution of precursor concentration equations. Finally, a multi-channel one-phase thermal hydraulic model is coupled to the proposed methodology. Transient equations are then solved at each step using the GMRES technique. To show the sufficiency of proposed transient SP3-ACMFD approximation for a full core analysis, a comparison is made using transport peers as the reference. To further demonstrate superiority, results are compared with a 3D multi-group transient diffusion solver developed as a byproduct of this work. Outcomes confirm that the idea can be considered as an economic interim approach which is superior to the diffusion approximation, and comparable with transport in results.

부스트 컨버터를 가진 정지형 여자기의 과도 안정도 해석 (TRANSIENT STABILITY ANALYSIS OF STATIC-EXCITER WITH BOOST CONVERTER)

  • 김찬기;류홍우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.204-210
    • /
    • 1997
  • The paper deals with the design and evaluation of a new static-exciter for generator excitation systems to improve the steady-state and transient stabilities. It increases or maintains the generator field current by boosting the field voltage in the case of an input AC line voltage drop during and immediately after a fault. The validity of the proposed excitation system is verified with computer simulation. The simulation results of the stability analysis on the generator with the proposed exciter is better than that of a conventional static exciter and a conventional AC exciter. Also, this proposed exciter can be simply implemented and controlled by modern power electronics technology.

  • PDF

주퇴충격하중을 받는 궤도차량 구조물의 천이응력해석 (Transient stress analysis of tracked vehicle structures under recoil impact load)

  • 이영신;김용환;김영완;김동수;성낙훈
    • 오토저널
    • /
    • 제15권3호
    • /
    • pp.111-119
    • /
    • 1993
  • In this study, the transient impact structural stress analysis of tracked vehicle structures under recoil impact load is investigated. ANSYS, ABAQUS Code are used for modelling and analytical procedures. The highest maximum Tresca stress occurs on race ring portion and its stress level is (.sigma.$_{T}$)$_{max}$ =20-40kgf/m $m^{2}$. The second highest stress occurs on upper plate of chassis and down plate of turret. The maximum stress level increases with loading direction and elevation angle. The results from liner static load analysis are very much different with impact analysis. Therefore, the practical solutions of structures under impact load can be obtained by only nonlinear transient impact analysis. The impact stress analysis of the steel vehicle structures is conducted. The maximum stress level is less than (.sigma.$_T/)$_{max}$m $m^{2}$. So, the design concept of steel structures can be adapted for new alternatives.s.s.s..s.

  • PDF