• 제목/요약/키워드: Static Strength Analysis

검색결과 646건 처리시간 0.024초

외부장착물지지 주익구조 정적 시험 및 해석 (Static Test and Analysis of Wing Support Structure for External Stores)

  • 엄원섭;윤종민
    • 항공우주시스템공학회지
    • /
    • 제9권1호
    • /
    • pp.28-34
    • /
    • 2015
  • Armed aircraft of a basic trainer class installs external stores under wing box by using pylon and performs an operation such as weapon delivery and jettison, and should be designed to withstand all kinds of loads applied to external stores. The static strength test of pylons and wing box was performed to assess the static strength of pylon and their support structures for substantiation. Based on the test, the structures were verified to fully satisfy a given design requirement. In this paper, methods of test load generation of wing box and pylon, evaluation of test result data and design result of test set-up were presented. Comparing the FEM analysis with the same test data can lead to good match and reasonable deviation between both. Finally, based on the test and the analysis, the static strength of test article was substantiated and the reliability and effectiveness of analysis math model were obtained.

굴삭기의 정적/동적 강도 해석법에 대한 연구 (Study on the Static and Dynamic Structural Analysis Procedure of Excavators)

  • 정준모;김규성;장영식;최익흥;허민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.537-543
    • /
    • 2003
  • This paper presents the improved procedure to assess static and dynamic strength of crawler type excavators. A fully integrated model including front attachment and chassis was prepared for structural analysis. In this paper, two types of loading input methods were investigated and the method imposing digging force directly on bucket tooth was more convenient than imposing cylinder reaction force on cylinder pin even if the two methods showed no discrepancy in analysis results. Static strength analysis was carried out for eight analysis scenarios based on two extreme digging positions, maximum digging reach position and maximum digging force positions. The results from static strength analysis were compared with measured stresses, cylinder pressures and digging forces and showed a good quantitative agreement with measured data. Dynamic strength analysis was carried out for simple reciprocation of boom cylinders. It was recognized that the effect of compressive stiffness of hydraulic oil was very important for dynamic structural behavior. The results from dynamic strength analysis including hydraulic oil stiffness were also compared with measured acceleration data and showed a qualitative agreement with measured data.

  • PDF

와전류 제동장치를 포함한 한국형 고속전철 대차의 정적강도 및 피로강도 평가 (Evaluation of Static Strength and Fatigue Strength for Bogie of a Korea High Speed Train Including Eddy Current Brake System)

  • 노규석;이상록;강재윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 2001
  • A FEM-based analytical approach was used to evaluate the static strength and the fatigue strength of a KHST bogie including eddy current brake system. Calculation was carried out in the fields of linearity and small deformation. The yield strengths were used as criteria for evaluating the static strength and the fatigue limits were used as criteria for evaluating the fatigue strength. The analysis results show that there is not any location that exceeds the allowable criteria.

  • PDF

변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정 (Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure)

  • 설윤정;박지훈;곽병훈;김대호
    • 한국지진공학회논문집
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2022
  • Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

Static strength of collar-plate reinforced tubular T-joints under axial loading

  • Shao, Yong-Bo
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.323-342
    • /
    • 2016
  • To study the effect of collar-plate reinforcement on the static strength of tubular T-joints under axial loading, fundamental research work is carried out from both experimental test and finite element (FE) simulation. Through experimental tests on 7 collar-plate reinforced and 7 corresponding un-reinforced tubular T-joints under axial loading, the reinforcing efficiency is investigated. Thereafter, the static strengths of the above 14 models are analyzed by using FE method, and it is found that the numerical results agree reasonably well with the experimental data to prove the accuracy of the presented FE model. Additionally, a parametric study is conducted to analyze the effect of some geometrical parameters, i.e., the brace-to-chord diameter ratio ${\beta}$, the chord diameter-to-chord wall thickness ratio $2{\gamma}$, collar-plate thickness to chord wall thickness ratio ${\tau}_c$, and collar-plate length to brace diameter ratio $l_c/d_1$, on the static strength of a tubular T-joint. The parametric study shows that the static strength can be greatly improved by increasing the collar-plate thickness to chord wall thickness ratio ${\tau}_c$ and the collar-plate length to brace diameter ratio $l_c/d_1$. Based on the numerical results, parametric equations are obtained from curving fitting technique to estimate the static strength of a tubular T-joint with collar-plate reinforcement under axial loading, and the accuracy of these equations is also evaluated from error analysis.

승용차 알루미늄 멀티링크 현가장치 코너모듈의 실험적 정강도 특성 평가 (Experimental Static Strength Evaluation of a Passenger Car Aluminium Multi-link Suspension Corner Module)

  • 조원용;최규재
    • 한국자동차공학회논문집
    • /
    • 제21권4호
    • /
    • pp.166-173
    • /
    • 2013
  • An aluminum suspension corner module is widely used in high class passenger cars to reduce vehicle weight and improve fuel economy. According to the change of material and suspension type, the evaluation of the static strength and failure mode of the corner module is important. In this study, static strength and failure mode analysis of aluminium multi-link suspension corner module is presented. Static strength test system is designed and static failure mode tests of the corner module are carried out in longitudinal, lateral, and vertical direction. From the resuls of the tests we found that the failure modes are different compare to those of the steel corner module. The static failure modes and load-displacement curves of this study will be used as a guidance in design of a passenger car aluminium multi-link suspension corner module.

Dynamic Increase factor based on residual strength to assess progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • 제25권5호
    • /
    • pp.617-624
    • /
    • 2017
  • In this study, a new empirical method is presented to obtain Dynamic Increase Factor (DIF) in nonlinear static analysis of structures against sudden removal of a gravity load-bearing element. In this method, DIF is defined as a function of minimum ratio of difference between maximum moment capacity ($M_u$) and moment demand ($M_d$) to plastic moment capacity ($M_p$) under unamplified gravity loads of elements. This function determines the residual strength of a damaged building before amplified gravity loads. For each column removal location, a nonlinear dynamic analysis and a step-by-step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived, which correspond to the ratio min $[(M_u-M_d)/M_p]$ of beams in the bays immediately adjacent to the removed column, and at all floors above it. Therefore, the new DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of a moment frame structure. The proposed DIF formulas can estimate the real residual strength of a structure based on critical member.

내부 환보강 T형 관이음부의 정적강도 (Static Strength of Internally Ring-Stiffened Tubular T-Joints)

  • 조현만;류연선
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.70-78
    • /
    • 2004
  • In order to increase the load carrying capacity of tubular structures, the joints of tubular members are usually reinforced with various reinforcement system. A stiffening method with internal ring stiffeners is effectively used for the steel tubular joint with a large diameter. In this study, the behavior of internally ring-stiffened tubular T-joints subjected to axial loading is assessed. For the parametric study, nonlinear finite element analyses are used to compute the static strength on non-stiffened and ring-stiffened T-joints. Based on the numerical results, an internal ring stiffener is found to be efficient in improving the static strength. The influence of geometric parameters has been determined, and the reinforcement effect are evaluated. Based on the FE results, regression analises are performed considering the practical size of ring stiffener. Finally strength estimation formulas for ring-stiffened tubular T-joints are proposed.

단부객차대차의 정적강도 및 피로강도 평가 (Evaluation of static and fatigue strength for end trailer bogie)

  • 조우강;한성욱;송시엽;박근수;박형순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.155-161
    • /
    • 2007
  • A bogie frame is typical safty part of railway vehicle. Main performance of a bogie frame is to support a car body and passenger weight and transfer traction and braking force. This paper is to evaluate the static strength and fatigue strength for the end trailer bogie with UIC 615-4 code. Therefore stress analysis of the end trailer bogie frame has been performed for various loading condition according to the UIC 615-4 code and haigh diagram is used for evaluation of fatigue strength. By the results of these analysis, static and fatigue strength of the end trailer bogie is satisfied with a applied criterion.

  • PDF

달착륙선 충격흡수장치용 알루미늄 허니콤의 Crush Strength에 관한 연구 (Study of Crush Strength of Aluminum Honeycomb for Shock Absorber of Lunar Lander)

  • 김신;이혁희;김현덕;박정선;임재혁;황도순
    • 항공우주시스템공학회지
    • /
    • 제4권3호
    • /
    • pp.1-5
    • /
    • 2010
  • Understanding the crushing behaviour of aluminum honeycombs under dynamic loading is useful for crash simulations of vehicles and for design of impacting energy absorbers. In the study of honeycomb crushing under quasi-static, dynamic loading, the most important parameter is crush strength. Crush strength is indicated to energy absorption characteristic of aluminum honeycomb. In this study, Using Finite Element Analysis carried out crush strength of hexagonal aluminum honeycomb then the results was compared with Quasi-static test. Consequently, Crush strength is different in quasi-static loading and dynamic loading about 16%.

  • PDF