• Title/Summary/Keyword: Static Stiffness Test

Search Result 316, Processing Time 0.034 seconds

Detection of Manufacturing Defects in Stiffness of CFTA Girder using Static Loading (정적 시험을 사용한 CFTA거더의 제조시 강성 결함 탐색)

  • Kim, Doo-Kie;Alfahdawi, Nathem;Cui, Jintao;Park, Kyung-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.1
    • /
    • pp.109-116
    • /
    • 2012
  • This paper presents a study on the nonlinear behavior of an innovative bridge girder made from concrete-filled and tied tubular steel arch (CFTA) under static loading. Manufacturing of the CFTA girder may have defects which may highly affect the symmetry and performance of the structure. A simple method is proposed by using stiffness extracted from static test data to detect manufacturing defects of the CFTA girder. A three-dimensional finite element model was used in the numerical analysis in order to verify the method. The proposed method was experimentally validated through static tests of the CFTA girder. The application of the proposed method showed that it is effective in identifying invisible manufacturing defects of the CFTA girder, especially for mass production of a standard type in the factory.

Comparison of Sit and Reach Test, Straight Leg Raise Test and Visual Analogue Scale When Applying Static Stretching and Mulligan's Two Leg Rotation in Young Adults with Hamstring Shortness

  • Lee, Ji Hoon;Kim, Ji Young;Kim, Hye Sun;Lee, A Young;Lim, Hyoung Won
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.5
    • /
    • pp.266-272
    • /
    • 2019
  • Purpose: This study compared the effects of Static stretching and Mulligan's Two-leg rotation about the Hamstring flexibility, Hip range of motion, and pain. Methods: The subjects were allocated randomly into two groups: Static stretching group (n=13) and Mulligan's two leg rotation group (n=14). The study was designed with stretching protocols for four minutes and thirty seconds per day five times a week for three weeks in total. Measurements, including the Sit and reach test, Active/Passive Straight leg raise, and Visual analogue scale, were conducted before and after the intervention. The data were analyzed using a paired t-test and independent t-test. Results: The flexibility of the two leg rotation group was higher than the static stretching group after the intervention. The post-sit and reach test value of the two leg rotation group was significantly higher than the pre-sit and reach test value of the static stretching group. In addition, the variance of the sit and reach test of the two leg rotation group was significantly higher than that of the static stretching group. Conclusion: These results showed that two leg rotation techniques have a positive effect on the changes in the sit and reach test and active straight leg raise test. Two leg rotation techniques can be recommended as a self-stretching and easier way to stabilize the lumbopelvic rhythm, reduce the stiffness of the muscle and relieve pain. This is effective in preventing muscle damage, enabling muscle relaxation and reducing the risk of injury to the spine during daily lives and in sports activities.

Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels (구조용단열패널의 정적가력과 반복가력 성능 평가)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

Static performance of a new GFRP-metal string truss bridge subjected to unsymmetrical loads

  • Zhang, Dongdong;Yuan, Jiaxin;Zhao, Qilin;Li, Feng;Gao, Yifeng;Zhu, Ruijie;Zhao, Zhiqin
    • Steel and Composite Structures
    • /
    • v.35 no.5
    • /
    • pp.641-657
    • /
    • 2020
  • A unique lightweight string truss deployable bridge assembled by thin-walled fiber reinforced polymer (FRP) and metal profiles was designed for emergency applications. As a new structure, investigations into the static structural performance under the serviceability limit state are desired for examining the structural integrity of the developed bridge when subjected to unsymmetrical loadings characterized by combined torsion and bending. In this study, a full-scale experimental inspection was conducted on a fabricated bridge, and the combined flexural-torsional behavior was examined in terms of displacement and strains. The experimental structure showed favorable strength and rigidity performances to function as deployable bridge under unsymmetrical loading conditions and should be designed in accordance with the stiffness criterion, the same as that under symmetrical loads. In addition, a finite element model (FEM) with a simple modeling process, which considered the multi segments of the FRP members and realistic nodal stiffness of the complex unique hybrid nodal joints, was constructed and compared against experiments, demonstrating good agreement. A FEM-based numerical analysis was thereafter performed to explore the effect of the change in elastic modulus of different FRP elements on the static deformation of the bridge. The results confirmed that the change in elastic modulus of different types of FRP element members caused remarkable differences on the bending and torsional stiffness of the hybrid bridge. The global stiffness of such a unique bridge can be significantly enhanced by redesigning the critical lower string pull bars using designable FRP profiles with high elastic modulus.

A Behavior Analysis of HSR Concrete Slab Track under Variety of Rail Pad Static Stiffness on Fatigue Effect (피로효과를 고려한 레일패드의 정적스프링계수 변화에 따른 콘크리트 슬래브 제도의 거동분석)

  • Park, Yong-Gul;Kang, Kee-Dong;Choi, Jung-Youl
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.499-505
    • /
    • 2007
  • The major effective of this study is to investigate the fatigue effects of rail pad on High Speed Railway with concrete slab track system. It analyzed the mechanical behaviors of HSR concrete slab track with applying rail pad stiffness based on fatigue effect (hardening and increasing stiffness) on the 3-dimensional FE analysis and laboratory test for static & dynamic characteristics. As a result, the hardening of rail pad due to fatigue loading condition are negative effect for the static & dynamic response of concrete stab track which is before act on fatigue effect. The analytical and experimental study are carried out to investigate rail pad on fatigue effected increase vertical acceleration and stress and decrease suitable deflection on slab track. And rail pad based on fatigue effect induced dynamic maximum stresses, the increase of damage of slab track is predicted by adopting fatigue effected rail pad. after due consideration. The servicing HSR concrete slab track with resilient track system has need of the reasonable determination after due consideration fatigue effect of rail pad stiffness which could be reducing the effect of static and dynamic behavior that degradation phenomenon of structure by an unusual response characteristic and a drop durability.

Retaining Wall System Using the Compressible Inclusion Function of EPS (EPS의 압축성을 이용한 콘크리트 옹벽 시스템 연구)

  • 김진만;김호비;조삼덕;주태성;최봉혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.411-418
    • /
    • 2001
  • The last 30 years have been significant worldwide growth in the use of EPS as a lightweight fill material. This paper analyzes the compressible inclusion function of EPS which can results in reduction of static earth pressure by accomodating the movement of retained soil. A series of model tests was conducted to evaluate the reduction of static earth pressure using EPS inclusion and determine the optimum stiffness of EPS, Also, field test was conducted to evaluate the reduction of static earth pressure using EPS inclusion. Based on field test it is found that the magnitude of static earth pressure was reduced about 20% compared with theoretical active earth pressure.

  • PDF

A Study on Characteristics of PRAT and Cornering due to the Belt Angle of Tire by the FEM (FEM을 이용한 타이어의 벨트각도에 따른 PRAT 및 코너링 특성 연구)

  • Sung, Ki-Deug;Kim, Seong-Rae;Kim, Ki-Hyun;Kim, Sun-Joo;Cho, Choon-Tack
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.104-112
    • /
    • 2006
  • The influence of tire belt angle on the Plysteer Residual Aligning Torque(PRAT) and the cornering stiffness by the FEM has been studied. The PRAT is a performance factor of the tire about vehicle pull, and the cornering stiffness has relation to vehicle steering response of outdoor test. To validate FE model for analysis, simulation data for both the static stiffness(vertical, lateral) and the PRAT have been compared with the experimental data. In addition to the characteristics of the PRAT and the cornering stiffness due to the tire belt angle, rolling and cornering contact characteristics have been studied. The tendency of the PRAT and the cornering stiffness due to the belt angle can be used as a guide line for the tire design in relation to vehicle pull and vehicle steering response.

Experimental hysteretic behavior of in-plane loaded reinforced grouted multi-ribbed aerated concrete blocks masonry walls

  • Li, Sheng-Cai;Dong, Jian-Xi;Li, Li-Feng
    • Structural Engineering and Mechanics
    • /
    • v.41 no.1
    • /
    • pp.95-112
    • /
    • 2012
  • In order to analyze the experimental hysteretic behavior of the in-plane loaded reinforced grouted multi-ribbed aerated concrete blocks masonry walls (RGMACBMW), we have carried out the pseudo static testing on the six specimens of RGMACBMW. Based on the test results and shear failure characteristics, the shear force hysteretic curves and displacement envelope curves of the models were obtained and discussed. On the basis of the hysteretic curves a general skeleton curve of the shear force and displacement was formed. The restoring model was adopted to analyze the seismic behavior and earthquake response of RGMACBMW. The deformation capacity of the specimens was discussed, and the formulas for calculating the lateral stiffness of the walls at different loading stages were proposed as well. The average lateral displacement ductility factor of RGMACBMW calculated based on the test results was 3.16. This value illustrates that if the walls are appropriately designed, it can fully meet the seismic requirement of the structures. The quadri-linear restoring models of the walls degradation by the test results accurately reflect the hysteretic behaviors and skeleton curves of the masonry walls. The restoring model can be applied to the RGMACBMW structure in earthquake response analysis.

Influence of neck width on the performance of ADAS device with diamond-shaped hole plates

  • Wu, Yingxiong;Lu, Jianfeng;Chen, Yun
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.19-32
    • /
    • 2020
  • Metallic energy-dissipation dampers are widely used in structures. They are comprised of an added damping and stiffness (ADAS) device with many parallel, diamond-shaped hole plates, the neck width of which is an important parameter. However, no studies have analyzed the neck width's influence on the ADAS device's performance. This study aims to better understand that influence by conducting a pseudo-static test on ADAS, with three different neck widths, and performing finite element analysis (FEA) models. Based on the FEA results and mechanical theory, a design neck width range was proposed. The results showed that when the neck width was within the specified range, the diamond-shaped hole plate achieved an ideal yield state with minimal stress concentration, where the ADAS had an optimal energy dissipation performance and the brittle shear fracture on the neck was avoided. The theoretical values of the ADAS yield loads were in good agreement with the test values. While the theoretical value of the elastic stiffness was lower than the test value, the discrepancy could be reduced with the proposed modified coefficient.

A Development of Pivoting Composite Wing for Mounting Kit (키트용 접이식 복합재 날개 개발)

  • Joo, Young-Sik;Jun, Woo-Chul;Byun, Kwan-Hwa;Cho, Chang-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.486-492
    • /
    • 2013
  • The pivoting composite wing is developed for the kit to be mounted on the external stores. The wing has a pivoting structure for the installation to an aircraft and high aspect ratio to increase lift drag ratio. The wing needs to be light and have sufficient strength and stiffness to satisfy structural design requirements. The wing is designed with carbon fiber composite and the structural parts are integrated to reduce cost to manufacture. In order to verify the structural performances, the design load analysis and flight load survey, the static analysis and test, the ground vibration test and flutter analysis are performed. It is shown that the wing has sufficient structural strength and stiffness to satisfy the structural design requirements.